Lightweight Classifier for Detecting Intracranial Hemorrhage in Ultrasound Data
- URL: http://arxiv.org/abs/2510.20857v1
- Date: Wed, 22 Oct 2025 09:04:42 GMT
- Title: Lightweight Classifier for Detecting Intracranial Hemorrhage in Ultrasound Data
- Authors: Phat Tran, Enbai Kuang, Fred Xu,
- Abstract summary: Intracranial hemorrhage (ICH) secondary to Traumatic Brain Injury (TBI) represents a critical diagnostic challenge.<n>Current diagnostic modalities including Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) have significant limitations.<n>This study investigates machine learning approaches for automated ICH detection using Ultrasound Tissue Pulsatility Imaging (TPI)
- Score: 0.5461938536945722
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Intracranial hemorrhage (ICH) secondary to Traumatic Brain Injury (TBI) represents a critical diagnostic challenge, with approximately 64,000 TBI-related deaths annually in the United States. Current diagnostic modalities including Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) have significant limitations: high cost, limited availability, and infrastructure dependence, particularly in resource-constrained environments. This study investigates machine learning approaches for automated ICH detection using Ultrasound Tissue Pulsatility Imaging (TPI), a portable technique measuring tissue displacement from hemodynamic forces during cardiac cycles. We analyze ultrasound TPI signals comprising 30 temporal frames per cardiac cycle with recording angle information, collected from TBI patients with CT-confirmed ground truth labels. Our preprocessing pipeline employs z-score normalization and Principal Component Analysis (PCA) for dimensionality reduction, retaining components explaining 95% of cumulative variance. We systematically evaluate multiple classification algorithms spanning probabilistic, kernel-based, neural network, and ensemble learning approaches across three feature representations: original 31-dimensional space, reduced subset, and PCA-transformed space. Results demonstrate that PCA transformation substantially improves classifier performance, with ensemble methods achieving 98.0% accuracy and F1-score of 0.890, effectively balancing precision and recall despite class imbalance. These findings establish the feasibility of machine learning-based ICH detection in TBI patients using portable ultrasound devices, with applications in emergency medicine, rural healthcare, and military settings where traditional imaging is unavailable.
Related papers
- Noninvasive Intracranial Pressure Estimation Using Subspace System Identification and Bespoke Machine Learning Algorithms: A Learning-to-Rank Approach [3.213638765666833]
A machine learning framework was proposed to obtain accurate mean ICP values using arbitrary noninvasive signals.<n>A mapping function to describe the relationship between the features of noninvasive signals and the estimation errors is learned using innovative ranking constraints.<n>Our results demonstrate the feasibility of the proposed noninvasive ICP estimation approach.
arXiv Detail & Related papers (2026-01-28T18:10:31Z) - A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking [1.2938481923855734]
MDS ICU is a unified machine learning framework that fuses routinely collected data including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage to provide continuous predictive support during ICU stays.<n>We trained a deep learning architecture that combines structured state space S4 encoders for ECG waveforms with multilayer perceptron RealMLP encoders for tabular data to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication needs, and acute deterioration.<n>Analysis showed close agreement between predicted and observed risks, with consistent gains from ECG waveform integration.
arXiv Detail & Related papers (2026-01-10T18:11:12Z) - AI-Powered Early Detection of Critical Diseases using Image Processing and Audio Analysis [0.4356470230135012]
This paper presents a multimodal artificial intelligence (AI) diagnostic framework integrating image analysis, thermal imaging, and audio signal processing.<n>A fine-tuned MobileNetV2 convolutional neural network was trained on the ISIC 2019 dataset for skin lesion classification.<n>A support vector machine (SVM) with handcrafted features was employed for thermal clot detection, achieving 86.4% accuracy.<n>The framework provides a promising step toward scalable, real-time, and accessible AI-based pre-diagnostic healthcare solutions.
arXiv Detail & Related papers (2025-10-29T06:09:17Z) - Automated Labeling of Intracranial Arteries with Uncertainty Quantification Using Deep Learning [2.6279333406008476]
We present a deep learning-based framework for automated artery labeling from 3D Time-of-Flight Magnetic Resonance Angiography (3D ToF-MRA)<n>Our framework offers a scalable, accurate, and uncertainty-aware solution for automated cerebrovascular labeling, supporting downstream hemodynamic analysis and facilitating clinical integration.
arXiv Detail & Related papers (2025-09-22T12:57:21Z) - A Novel Attention-Augmented Wavelet YOLO System for Real-time Brain Vessel Segmentation on Transcranial Color-coded Doppler [49.03919553747297]
We propose an AI-powered, real-time CoW auto-segmentation system capable of efficiently capturing cerebral arteries.<n>No prior studies have explored AI-driven cerebrovascular segmentation using Transcranial Color-coded Doppler (TCCD)<n>The proposed AAW-YOLO demonstrated strong performance in segmenting both ipsilateral and contralateral CoW vessels.
arXiv Detail & Related papers (2025-08-19T14:41:22Z) - Signal-based AI-driven software solution for automated quantification of metastatic bone disease and treatment response assessment using Whole-Body Diffusion-Weighted MRI (WB-DWI) biomarkers in Advanced Prostate Cancer [0.490307469564307]
We developed an AI-driven software solution to quantify metastatic bone disease from WB-DWI scans.<n>Core technologies include: (i) a weakly-supervised Residual U-Net model generating a skeleton probability map to isolate bone; (ii) a statistical framework for WB-DWI intensity normalisation; and (iii) a shallow convolutional neural network.<n>Software achieved 80.5% accuracy, 84.3% sensitivity, and 85.7% specificity in assessing response to treatment.
arXiv Detail & Related papers (2025-05-13T22:57:49Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [46.36100528165335]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - Classification of Heart Sounds Using Multi-Branch Deep Convolutional Network and LSTM-CNN [7.136933021609078]
This study develops and evaluates novel deep learning architectures that offer fast, accurate, and cost-effective methods for automatic diagnosis of cardiac diseases.<n>We propose two innovative methodologies: first, a Multi-Branch Deep Convolutional Neural Network (MBDCN) that emulates human auditory processing by utilizing diverse convolutional filter sizes and power spectrum input for enhanced feature extraction.<n>Second, a Long Short-Term Memory-Convolutional Neural (LSCN) model that integrates LSTM blocks with MBDCN to improve time-domain feature extraction.
arXiv Detail & Related papers (2024-07-15T13:02:54Z) - SQUWA: Signal Quality Aware DNN Architecture for Enhanced Accuracy in Atrial Fibrillation Detection from Noisy PPG Signals [37.788535094404644]
Atrial fibrillation (AF) significantly increases the risk of stroke, heart disease, and mortality.
Photoplethysmography ( PPG) signals are susceptible to corruption from motion artifacts and other factors often encountered in ambulatory settings.
We propose a novel deep learning model, designed to learn how to retain accurate predictions from partially corrupted PPG.
arXiv Detail & Related papers (2024-04-15T01:07:08Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - Deep-Learning Tool for Early Identifying Non-Traumatic Intracranial
Hemorrhage Etiology based on CT Scan [40.51754649947294]
The deep learning model was developed with 1868 eligible NCCT scans with non-traumatic ICH collected between January 2011 and April 2018.
The model's diagnostic performance was compared with clinicians's performance.
The clinicians achieve significant improvements in the sensitivity, specificity, and accuracy of diagnoses of certain hemorrhage etiologies with proposed system augmentation.
arXiv Detail & Related papers (2023-02-02T08:45:17Z) - Controlling False Positive/Negative Rates for Deep-Learning-Based
Prostate Cancer Detection on Multiparametric MR images [58.85481248101611]
We propose a novel PCa detection network that incorporates a lesion-level cost-sensitive loss and an additional slice-level loss based on a lesion-to-slice mapping function.
Our experiments based on 290 clinical patients concludes that 1) The lesion-level FNR was effectively reduced from 0.19 to 0.10 and the lesion-level FPR was reduced from 1.03 to 0.66 by changing the lesion-level cost.
arXiv Detail & Related papers (2021-06-04T09:51:27Z) - DeepBeat: A multi-task deep learning approach to assess signal quality
and arrhythmia detection in wearable devices [0.0]
We develop a multi-task deep learning method to assess signal quality and arrhythmia event detection in wearable photoplethysmography devices for real-time detection of atrial fibrillation (AF)
We train our algorithm on over one million simulated unlabeled physiological signals and fine-tune on a curated dataset of over 500K labeled signals from over 100 individuals from 3 different wearable devices.
We show that two-stage training can help address the unbalanced data problem common to biomedical applications where large well-annotated datasets are scarce.
arXiv Detail & Related papers (2020-01-01T07:41:28Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.