BRIQA: Balanced Reweighting in Image Quality Assessment of Pediatric Brain MRI
- URL: http://arxiv.org/abs/2510.26661v1
- Date: Thu, 30 Oct 2025 16:29:09 GMT
- Title: BRIQA: Balanced Reweighting in Image Quality Assessment of Pediatric Brain MRI
- Abstract summary: We propose BRIQA (Balanced Reweighting in Image Quality Assessment), which addresses class imbalance in artifact levels.<n>BRIQA uses gradient-based loss reweighting to dynamically adjust per-class contributions and employs a rotating scheme to ensure consistent exposure to underrepresented classes.<n>BRIQA improves average macro F1 score from 0.659 to 0.706, with notable gains in Noise (0.430), Zipper (0.098), Positioning (0.097), Contrast (0.217), Motion (0.022), and Banding (0.012) artifact severity classification.
- Score: 2.30091479294656
- License: http://creativecommons.org/licenses/by-nc-sa/4.0/
- Abstract: Assessing the severity of artifacts in pediatric brain Magnetic Resonance Imaging (MRI) is critical for diagnostic accuracy, especially in low-field systems where the signal-to-noise ratio is reduced. Manual quality assessment is time-consuming and subjective, motivating the need for robust automated solutions. In this work, we propose BRIQA (Balanced Reweighting in Image Quality Assessment), which addresses class imbalance in artifact severity levels. BRIQA uses gradient-based loss reweighting to dynamically adjust per-class contributions and employs a rotating batching scheme to ensure consistent exposure to underrepresented classes. Through experiments, no single architecture performs best across all artifact types, emphasizing the importance of architectural diversity. The rotating batching configuration improves performance across metrics by promoting balanced learning when combined with cross-entropy loss. BRIQA improves average macro F1 score from 0.659 to 0.706, with notable gains in Noise (0.430), Zipper (0.098), Positioning (0.097), Contrast (0.217), Motion (0.022), and Banding (0.012) artifact severity classification. The code is available at https://github.com/BioMedIA-MBZUAI/BRIQA.
Related papers
- Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts [56.74856091904914]
We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction.<n>ScanCLIP derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features.<n>A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction.
arXiv Detail & Related papers (2026-05-29T02:48:23Z) - Attention-Gated Convolutional Networks for Scanner-Agnostic Quality Assessment [0.0]
Motion artifacts present a significant challenge in structural MRI (sMRI)<n>We propose a hybrid CNN-Attention framework designed for robust, site-invariant MRI quality assessment.<n>Our architecture integrates a hierarchical 2D CNN encoder for local spatial feature extraction with a multi-head cross-attention mechanism to model global dependencies.
arXiv Detail & Related papers (2026-04-16T14:25:11Z) - LMM-IQA: Image Quality Assessment for Low-Dose CT Imaging [0.0]
Low-dose computed tomography represents a significant improvement in patient safety through lower radiation doses.<n>However, increased noise, blur, and contrast loss can diminish diagnostic quality.<n>We propose an LLM-based quality assessment system that generates both numerical scores and textual descriptions of degradations.
arXiv Detail & Related papers (2025-11-10T16:56:11Z) - Adapting HFMCA to Graph Data: Self-Supervised Learning for Generalizable fMRI Representations [57.054499278843856]
Functional magnetic resonance imaging (fMRI) analysis faces significant challenges due to limited dataset sizes and domain variability between studies.<n>Traditional self-supervised learning methods inspired by computer vision often rely on positive and negative sample pairs.<n>We propose adapting a recently developed Hierarchical Functional Maximal Correlation Algorithm (HFMCA) to graph-structured fMRI data.
arXiv Detail & Related papers (2025-10-05T12:35:01Z) - Motion Artifact Removal in Pixel-Frequency Domain via Alternate Masks and Diffusion Model [58.694932010573346]
Motion artifacts present in magnetic resonance imaging (MRI) can seriously interfere with clinical diagnosis.<n>We propose a novel unsupervised purification method which leverages pixel-frequency information of noisy MRI images to guide a pre-trained diffusion model to recover clean MRI images.
arXiv Detail & Related papers (2024-12-10T15:25:18Z) - A Deep-Learning-Based Label-free No-Reference Image Quality Assessment Metric: Application in Sodium MRI Denoising [0.0]
New MRI techniques, such as sodium MRI, generally suffer from low image quality due to an inherently low signal.
Deep learning models have a unique characteristic in that they are specialized to a characteristic training set.
We propose a novel DL-based NR-IQA metric, the Model Metric (MSM), which does not depend on ground-truth images or labels.
arXiv Detail & Related papers (2024-08-29T12:16:55Z) - Feature Denoising Diffusion Model for Blind Image Quality Assessment [58.5808754919597]
Blind Image Quality Assessment (BIQA) aims to evaluate image quality in line with human perception, without reference benchmarks.
Deep learning BIQA methods typically depend on using features from high-level tasks for transfer learning.
In this paper, we take an initial step towards exploring the diffusion model for feature denoising in BIQA.
arXiv Detail & Related papers (2024-01-22T13:38:24Z) - On Sensitivity and Robustness of Normalization Schemes to Input
Distribution Shifts in Automatic MR Image Diagnosis [58.634791552376235]
Deep Learning (DL) models have achieved state-of-the-art performance in diagnosing multiple diseases using reconstructed images as input.
DL models are sensitive to varying artifacts as it leads to changes in the input data distribution between the training and testing phases.
We propose to use other normalization techniques, such as Group Normalization and Layer Normalization, to inject robustness into model performance against varying image artifacts.
arXiv Detail & Related papers (2023-06-23T03:09:03Z) - Motion-related Artefact Classification Using Patch-based Ensemble and
Transfer Learning in Cardiac MRI [5.186000805926489]
We propose an automatic cardiac MRI quality estimation framework using ensemble and transfer learning.
Multiple pre-trained models were initialised and fine-tuned on 2-dimensional image patches sampled from the training data.
It achieved a classification accuracy of 78.8% and 70.0% on the training set and validation set, respectively.
arXiv Detail & Related papers (2022-10-14T11:31:40Z) - Automated SSIM Regression for Detection and Quantification of Motion
Artefacts in Brain MR Images [54.739076152240024]
Motion artefacts in magnetic resonance brain images are a crucial issue.
The assessment of MR image quality is fundamental before proceeding with the clinical diagnosis.
An automated image quality assessment based on the structural similarity index (SSIM) regression has been proposed here.
arXiv Detail & Related papers (2022-06-14T10:16:54Z) - Negligible effect of brain MRI data preprocessing for tumor segmentation [36.89606202543839]
We conduct experiments on three publicly available datasets and evaluate the effect of different preprocessing steps in deep neural networks.
Our results demonstrate that most popular standardization steps add no value to the network performance.
We suggest that image intensity normalization approaches do not contribute to model accuracy because of the reduction of signal variance with image standardization.
arXiv Detail & Related papers (2022-04-11T17:29:36Z) - Image Quality Assessment for Magnetic Resonance Imaging [4.05136808278614]
Image quality assessment (IQA) algorithms aim to reproduce the human's perception of the image quality.
We use outputs of neural network models trained to solve problems relevant to MRI.
Seven trained radiologists assess distorted images, with their verdicts then correlated with 35 different image quality metrics.
arXiv Detail & Related papers (2022-03-15T11:52:29Z) - Interpretability Aware Model Training to Improve Robustness against
Out-of-Distribution Magnetic Resonance Images in Alzheimer's Disease
Classification [8.050897403457995]
We propose an interpretability aware adversarial training regime to improve robustness against out-of-distribution samples originating from different MRI hardware.
We present preliminary results showing promising performance on out-of-distribution samples.
arXiv Detail & Related papers (2021-11-15T04:42:47Z) - Towards Ultrafast MRI via Extreme k-Space Undersampling and
Superresolution [65.25508348574974]
We go below the MRI acceleration factors reported by all published papers that reference the original fastMRI challenge.
We consider powerful deep learning based image enhancement methods to compensate for the underresolved images.
The quality of the reconstructed images surpasses that of the other methods, yielding an MSE of 0.00114, a PSNR of 29.6 dB, and an SSIM of 0.956 at x16 acceleration factor.
arXiv Detail & Related papers (2021-03-04T10:45:01Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.