Automatic segmentation of colorectal liver metastases for ultrasound-based navigated resection
- URL: http://arxiv.org/abs/2511.05253v1
- Date: Fri, 07 Nov 2025 14:13:31 GMT
- Title: Automatic segmentation of colorectal liver metastases for ultrasound-based navigated resection
- Authors: Tiziano Natali, Karin A. Olthof, Niels F. M. Kok, Koert F. D. Kuhlmann, Theo J. M. Ruers, Matteo Fusaglia,
- Abstract summary: Automated segmentation could enhance precision and efficiency in ultrasound-based navigation.<n>Eighty-five tracked 3D iUS volumes from 85 CRLM patients were used to train and evaluate a 3D U-Net.<n>Results: The cropped-volume model significantly outperformed the full-volume model across all metrics.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Introduction: Accurate intraoperative delineation of colorectal liver metastases (CRLM) is crucial for achieving negative resection margins but remains challenging using intraoperative ultrasound (iUS) due to low contrast, noise, and operator dependency. Automated segmentation could enhance precision and efficiency in ultrasound-based navigation workflows. Methods: Eighty-five tracked 3D iUS volumes from 85 CRLM patients were used to train and evaluate a 3D U-Net implemented via the nnU-Net framework. Two variants were compared: one trained on full iUS volumes and another on cropped regions around tumors. Segmentation accuracy was assessed using Dice Similarity Coefficient (DSC), Hausdorff Distance (HDist.), and Relative Volume Difference (RVD) on retrospective and prospective datasets. The workflow was integrated into 3D Slicer for real-time intraoperative use. Results: The cropped-volume model significantly outperformed the full-volume model across all metrics (AUC-ROC = 0.898 vs 0.718). It achieved median DSC = 0.74, recall = 0.79, and HDist. = 17.1 mm comparable to semi-automatic segmentation but with ~4x faster execution (~ 1 min). Prospective intraoperative testing confirmed robust and consistent performance, with clinically acceptable accuracy for real-time surgical guidance. Conclusion: Automatic 3D segmentation of CRLM in iUS using a cropped 3D U-Net provides reliable, near real-time results with minimal operator input. The method enables efficient, registration-free ultrasound-based navigation for hepatic surgery, approaching expert-level accuracy while substantially reducing manual workload and procedure time.
Related papers
- OREHAS: A fully automated deep-learning pipeline for volumetric endolymphatic hydrops quantification in MRI [0.5947663081597012]
OREHAS is the first fully automatic pipeline for volumetric quantification of endolymphatic hydrops.<n>It computes per-ear endolymphatic-to-vestibular volume ratios directly from whole MRI volumes.
arXiv Detail & Related papers (2026-01-26T11:19:21Z) - Click, Predict, Trust: Clinician-in-the-Loop AI Segmentation for Lung Cancer CT-Based Prognosis within the Knowledge-to-Action Framework [0.7340285482623061]
Lung cancer remains the leading cause of cancer mortality, with CT imaging central to screening, prognosis, and treatment.<n>Deep learning (DL) offers automation but faces barriers to clinical adoption.<n>This study develops a clinician-in-the-loop DL pipeline to enhance, prognostic accuracy, and clinical trust.
arXiv Detail & Related papers (2025-10-19T23:02:43Z) - DRBD-Mamba for Robust and Efficient Brain Tumor Segmentation with Analytical Insights [54.87947751720332]
Accurate brain tumor segmentation is significant for clinical diagnosis and treatment.<n>Mamba-based State Space Models have demonstrated promising performance.<n>We propose a dual-resolution bi-directional Mamba that captures multi-scale long-range dependencies with minimal computational overhead.
arXiv Detail & Related papers (2025-10-16T07:31:21Z) - A Novel Attention-Augmented Wavelet YOLO System for Real-time Brain Vessel Segmentation on Transcranial Color-coded Doppler [49.03919553747297]
We propose an AI-powered, real-time CoW auto-segmentation system capable of efficiently capturing cerebral arteries.<n>No prior studies have explored AI-driven cerebrovascular segmentation using Transcranial Color-coded Doppler (TCCD)<n>The proposed AAW-YOLO demonstrated strong performance in segmenting both ipsilateral and contralateral CoW vessels.
arXiv Detail & Related papers (2025-08-19T14:41:22Z) - A weakly-supervised deep learning model for fast localisation and delineation of the skeleton, internal organs, and spinal canal on Whole-Body Diffusion-Weighted MRI (WB-DWI) [0.0]
We developed an automated deep-learning pipeline based on a 3D patch-based Residual U-Net architecture.<n>We employed a multi-centre WB-DWI dataset comprising 532 scans from patients with Advanced Prostate Cancer (APC) or Multiple Myeloma (MM)<n>Relative median ADC differences between automated and manual full-body delineations were below 10%.<n>The model was 12x faster than the atlas-based registration algorithm.
arXiv Detail & Related papers (2025-03-26T17:03:46Z) - Epicardium Prompt-guided Real-time Cardiac Ultrasound Frame-to-volume Registration [50.602074919305636]
This paper introduces a lightweight end-to-end Cardiac Ultrasound frame-to-volume Registration network, termed CU-Reg.<n>We use epicardium prompt-guided anatomical clues to reinforce the interaction of 2D sparse and 3D dense features, followed by a voxel-wise local-global aggregation of enhanced features.
arXiv Detail & Related papers (2024-06-20T17:47:30Z) - Application of the nnU-Net for automatic segmentation of lung lesion on
CT images, and implication on radiomic models [1.8231394717039833]
A deep-learning automatic segmentation method was applied on computed tomography images of non-small-cell lung cancer patients.
The use of manual vs automatic segmentation in the performance of survival radiomic models was assessed, as well.
arXiv Detail & Related papers (2022-09-24T15:04:23Z) - CNN-based fully automatic wrist cartilage volume quantification in MR
Image [55.41644538483948]
The U-net convolutional neural network with additional attention layers provides the best wrist cartilage segmentation performance.
The error of cartilage volume measurement should be assessed independently using a non-MRI method.
arXiv Detail & Related papers (2022-06-22T14:19:06Z) - Real-time Virtual Intraoperative CT for Image Guided Surgery [13.166023816014777]
The work presents three methods, the tip motion-based, the tip trajectory-based, and the instrument based, for virtual intraoperative CT generation.
Surgical results show all three methods improve the Dice Similarity Coefficients > 86%, with F-score > 92% and precision.
The tip trajectory-based method was found to have best performance and reached 96.87% precision in surgical completeness evaluation.
arXiv Detail & Related papers (2021-12-05T16:06:34Z) - Systematic Clinical Evaluation of A Deep Learning Method for Medical
Image Segmentation: Radiosurgery Application [48.89674088331313]
We systematically evaluate a Deep Learning (DL) method in a 3D medical image segmentation task.
Our method is integrated into the radiosurgery treatment process and directly impacts the clinical workflow.
arXiv Detail & Related papers (2021-08-21T16:15:40Z) - Revisiting 3D Context Modeling with Supervised Pre-training for
Universal Lesion Detection in CT Slices [48.85784310158493]
We propose a Modified Pseudo-3D Feature Pyramid Network (MP3D FPN) to efficiently extract 3D context enhanced 2D features for universal lesion detection in CT slices.
With the novel pre-training method, the proposed MP3D FPN achieves state-of-the-art detection performance on the DeepLesion dataset.
The proposed 3D pre-trained weights can potentially be used to boost the performance of other 3D medical image analysis tasks.
arXiv Detail & Related papers (2020-12-16T07:11:16Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.