Cuffless Blood Pressure Estimation from Six Wearable Sensor Modalities in Multi-Motion-State Scenarios
- URL: http://arxiv.org/abs/2512.01653v1
- Date: Mon, 01 Dec 2025 13:26:30 GMT
- Title: Cuffless Blood Pressure Estimation from Six Wearable Sensor Modalities in Multi-Motion-State Scenarios
- Authors: Yiqiao Chen, Fazheng Xu, Zijian Huang, Juchi He, Zhenghui Feng,
- Abstract summary: The proposed method achieves mean absolute errors (MAE) of 3.60 mmHg for systolic BP (SBP) and 3.01 mmHg for diastolic BP (DBP)<n>From a clinical perspective, it attains Grade A for SBP, DBP, andMAP according to the British Hypertension Society (BHS) protocol.
- Score: 0.7871262900865523
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Cardiovascular disease (CVD) is a leading cause of morbidity and mortality worldwide, and sustained hypertension is an often silent risk factor, making cuffless continuous blood pressure (BP) monitoring with wearable devices important for early screening and long-term management. Most existing cuffless BP estimation methods use only photoplethysmography (PPG) and electrocardiography (ECG) signals, alone or in combination. These models are typically developed under resting or quasi-static conditions and struggle to maintain robust accuracy in multi-motion-state scenarios. In this study, we propose a six-modal BP estimation framework that jointly leverages ECG, multi-channel PPG, attachment pressure, sensor temperature, and triaxial acceleration and angular velocity. Each modality is processed by a lightweight branch encoder, contrastive learning enforces cross-modal semantic alignment, and a mixture-of-experts (MoE) regression head adaptively maps the fused features to BP across motion states. Comprehensive experiments on the public Pulse Transit Time PPG Dataset, which includes running, walking, and sitting data from 22 subjects, show that the proposed method achieves mean absolute errors (MAE) of 3.60 mmHg for systolic BP (SBP) and 3.01 mmHg for diastolic BP (DBP). From a clinical perspective, it attains Grade A for SBP, DBP, and mean arterial pressure (MAP) according to the British Hypertension Society (BHS) protocol and meets the numerical criteria of the Association for the Advancement of Medical Instrumentation (AAMI) standard for mean error (ME) and standard deviation of error (SDE).
Related papers
- Estimating Blood Pressure with a Camera: An Exploratory Study of Ambulatory Patients with Cardiovascular Disease [20.797887496336397]
Hypertension is a leading cause of morbidity and mortality worldwide.<n>The ability to diagnose and treat hypertension in the ambulatory population is hindered by limited access and poor adherence to current methods of monitoring blood pressure (BP)<n>Remote photoplethysmography (r) evaluates an individual's waveform through a standard camera without physical contact.
arXiv Detail & Related papers (2025-03-02T13:24:50Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [46.36100528165335]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - Leveraging Cardiovascular Simulations for In-Vivo Prediction of Cardiac Biomarkers [43.17768785084301]
We train an amortized neural posterior estimator on a newly built large dataset of cardiac simulations.<n>We incorporate elements modeling effects to better align simulated data with real-world measurements.<n>The proposed framework can further integrate in-vivo data sources to refine its predictive capabilities on real-world data.
arXiv Detail & Related papers (2024-12-23T13:05:17Z) - A Multi-scenario Attention-based Generative Model for Personalized Blood Pressure Time Series Forecasting [6.311504297463515]
Continuous blood pressure (BP) monitoring is essential for timely diagnosis and intervention in critical care settings.
In this work, we propose a personalized BP forecasting model mainly using electrocardiogram (ECG) and photoplethysmogram ( photoplethysmogram) signals.
Experiments are conducted on datasets collected from three diverse scenarios with BP measurements from 60 subjects total.
arXiv Detail & Related papers (2024-09-07T04:24:15Z) - PITN: Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation [37.94387581519217]
We introduce a novel physics-informed temporal network(PITN) with adversarial contrastive learning to enable precise BP estimation with very limited data.<n>Specifically, we first enhance the physics-informed neural network(PINN) with the temporal block for investigating BP dynamics' multi-periodicity.<n>We then employ adversarial training to generate extra physiological time series data, improving PITN's robustness in the face of sparse subject-specific data.
arXiv Detail & Related papers (2024-08-16T02:17:21Z) - TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing [5.255373360156652]
The paper introduces the TransfoRhythm framework, a Transformer-based architecture built upon the recently released physiological database, MIMIC-IV.<n>To our knowledge, this paper represents the first study to apply the MIMIC IV dataset for cuff-less BP estimation.
arXiv Detail & Related papers (2024-04-15T00:36:33Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - Hypertension Detection From High-Dimensional Representation of
Photoplethysmogram Signals [38.497450879376]
Early detection of hypertension is crucial in preventing significant health issues.
Some studies suggest a relationship between blood pressure and certain vital signals, such as Photoplethysmogram ( PPG)
In this paper, a high-dimensional representation technique based on random convolution kernels is proposed for hypertension detection using PPG signals.
arXiv Detail & Related papers (2023-07-31T00:09:23Z) - A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP)
from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signals [1.1695966610359496]
Most existing methods used in the hospitals for continuous monitoring of Blood Pressure (BP) are invasive.
In this study, we explored the applicability of autoencoders in predicting BP from non-invasively collectible signals such as Photoplethysmogram ( PPG) and ECG signals.
It was found that a very shallow, one-dimensional autoencoder can extract the relevant features to predict the SBP and DBP with the state-of-the-art performance on a very large dataset.
arXiv Detail & Related papers (2021-11-12T19:34:20Z) - Ambulatory blood pressure monitoring versus office blood pressure
measurement: Are there sex differences? [55.41644538483948]
Office Blood Pressure Measurement (OBP) is a technique performed in-office with the sphygmomanometer, while Ambulatory Blood Pressure Monitoring (ABPM) is a technique that measures blood pressure during 24h.
The aim of this study is to examine the possible influence of sex on the discrepancies between OBP and ABPM in 872 subjects with known or suspected hypertension.
arXiv Detail & Related papers (2021-06-04T10:09:44Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.