A Non-Invasive 3D Gait Analysis Framework for Quantifying Psychomotor Retardation in Major Depressive Disorder
- URL: http://arxiv.org/abs/2601.19526v1
- Date: Tue, 27 Jan 2026 12:07:21 GMT
- Title: A Non-Invasive 3D Gait Analysis Framework for Quantifying Psychomotor Retardation in Major Depressive Disorder
- Authors: Fouad Boutaleb, Emery Pierson, Mohamed Daoudi, Clémence Nineuil, Ali Amad, Fabien D'Hondt,
- Abstract summary: We propose a non-invasive computational framework that transforms monocular RGB video into clinically relevant 3D gait kinematics.<n>This novel pipeline enables the extraction of 297 explicit gait biomechanical biomarkers from a single camera capture.<n>Our method achieves an 83.3% accuracy in detecting Psychomotor retardation (PMR) and explains 64% of the variance in overall depression severity.
- Score: 4.909486568908741
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Predicting the status of Major Depressive Disorder (MDD) from objective, non-invasive methods is an active research field. Yet, extracting automatically objective, interpretable features for a detailed analysis of the patient state remains largely unexplored. Among MDD's symptoms, Psychomotor retardation (PMR) is a core item, yet its clinical assessment remains largely subjective. While 3D motion capture offers an objective alternative, its reliance on specialized hardware often precludes routine clinical use. In this paper, we propose a non-invasive computational framework that transforms monocular RGB video into clinically relevant 3D gait kinematics. Our pipeline uses Gravity-View Coordinates along with a novel trajectory-correction algorithm that leverages the closed-loop topology of our adapted Timed Up and Go (TUG) protocol to mitigate monocular depth errors. This novel pipeline enables the extraction of 297 explicit gait biomechanical biomarkers from a single camera capture. To address the challenges of small clinical datasets, we introduce a stability-based machine learning framework that identifies robust motor signatures while preventing overfitting. Validated on the CALYPSO dataset, our method achieves an 83.3% accuracy in detecting PMR and explains 64% of the variance in overall depression severity (R^2=0.64). Notably, our study reveals a strong link between reduced ankle propulsion and restricted pelvic mobility to the depressive motor phenotype. These results demonstrate that physical movement serves as a robust proxy for the cognitive state, offering a transparent and scalable tool for the objective monitoring of depression in standard clinical environments.
Related papers
- Non-Contact Physiological Monitoring in Pediatric Intensive Care Units via Adaptive Masking and Self-Supervised Learning [1.2744523252873352]
Contact-based sensors such as pulse oximeters may cause skin irritation and lead to patient discomfort.<n>Remote photometers offer a contactless alternative to monitor vital signs using facial video.<n>We introduce a progressive curriculum strategy for pretraining an expert model in the PICU setting.<n>Our framework achieves a reduction in mean absolute error relative to standard masked autoencoders and outperforms PhysFormer by 31%.
arXiv Detail & Related papers (2026-02-17T19:34:50Z) - Depression Detection Based on Electroencephalography Using a Hybrid Deep Neural Network CNN-GRU and MRMR Feature Selection [0.0]
This study investigates the detection and classification of depressive and non-depressive states using deep learning approaches.<n>The proposed framework combines convolutional neural networks (CNNs) and gated recurrent units (GRUs) to jointly extract spatial and temporal features from EEG recordings.<n>The results demonstrate that the proposed model achieves high performance in accurately identifying depressive states, with an overall accuracy of 98.74%.
arXiv Detail & Related papers (2026-01-16T02:58:17Z) - Automated Labeling of Intracranial Arteries with Uncertainty Quantification Using Deep Learning [2.6279333406008476]
We present a deep learning-based framework for automated artery labeling from 3D Time-of-Flight Magnetic Resonance Angiography (3D ToF-MRA)<n>Our framework offers a scalable, accurate, and uncertainty-aware solution for automated cerebrovascular labeling, supporting downstream hemodynamic analysis and facilitating clinical integration.
arXiv Detail & Related papers (2025-09-22T12:57:21Z) - Deconstructing Intraocular Pressure: A Non-invasive Multi-Stage Probabilistic Inverse Framework [0.0]
Glaucoma is a leading cause of irreversible blindness driven by elevated intraocular pressure (IOP)<n>We develop a framework to noninvasively estimate unmeasurable variables from sparse, routine data.<n>Our framework achieves excellent agreement with state-of-the-art tonography with precision comparable to direct physical instruments.
arXiv Detail & Related papers (2025-09-17T16:50:23Z) - Validation of Human Pose Estimation and Human Mesh Recovery for Extracting Clinically Relevant Motion Data from Videos [79.62407455005561]
Marker-less motion capture using human pose estimation produces results in-line with the results of both the IMU and MoCap kinematics.<n>While there is still room for improvement when it comes to the quality of the data produced, we believe that this compromise is within the room of error.
arXiv Detail & Related papers (2025-03-18T22:18:33Z) - Spatial-aware Transformer-GRU Framework for Enhanced Glaucoma Diagnosis from 3D OCT Imaging [3.093890460224435]
We present a novel deep learning framework that leverages the diagnostic value of 3D Optical Coherence Tomography ( OCT) imaging for automated glaucoma detection.<n>We integrate a pre-trained Vision Transformer on retinal data for rich slice-wise feature extraction and a bidirectional Gated Recurrent Unit for capturing inter-slice spatial dependencies.
arXiv Detail & Related papers (2024-03-08T22:25:15Z) - Automatic diagnosis of knee osteoarthritis severity using Swin
transformer [55.01037422579516]
Knee osteoarthritis (KOA) is a widespread condition that can cause chronic pain and stiffness in the knee joint.
We propose an automated approach that employs the Swin Transformer to predict the severity of KOA.
arXiv Detail & Related papers (2023-07-10T09:49:30Z) - A marker-less human motion analysis system for motion-based biomarker
discovery in knee disorders [60.99112047564336]
The NHS has been having increased difficulty seeing all low-risk patients, this includes but not limited to suspected osteoarthritis (OA) patients.
We propose a novel method of automated biomarker identification for diagnosis of knee disorders and the monitoring of treatment progression.
arXiv Detail & Related papers (2023-04-26T16:47:42Z) - Semantic Latent Space Regression of Diffusion Autoencoders for Vertebral
Fracture Grading [72.45699658852304]
This paper proposes a novel approach to train a generative Diffusion Autoencoder model as an unsupervised feature extractor.
We model fracture grading as a continuous regression, which is more reflective of the smooth progression of fractures.
Importantly, the generative nature of our method allows us to visualize different grades of a given vertebra, providing interpretability and insight into the features that contribute to automated grading.
arXiv Detail & Related papers (2023-03-21T17:16:01Z) - Pain level and pain-related behaviour classification using GRU-based
sparsely-connected RNNs [61.080598804629375]
People with chronic pain unconsciously adapt specific body movements to protect themselves from injury or additional pain.
Because there is no dedicated benchmark database to analyse this correlation, we considered one of the specific circumstances that potentially influence a person's biometrics during daily activities.
We proposed a sparsely-connected recurrent neural networks (s-RNNs) ensemble with the gated recurrent unit (GRU) that incorporates multiple autoencoders.
We conducted several experiments which indicate that the proposed method outperforms the state-of-the-art approaches in classifying both pain level and pain-related behaviour.
arXiv Detail & Related papers (2022-12-20T12:56:28Z) - Detecting Parkinsonian Tremor from IMU Data Collected In-The-Wild using
Deep Multiple-Instance Learning [59.74684475991192]
Parkinson's Disease (PD) is a slowly evolving neuro-logical disease that affects about 1% of the population above 60 years old.
PD symptoms include tremor, rigidity and braykinesia.
We present a method for automatically identifying tremorous episodes related to PD, based on IMU signals captured via a smartphone device.
arXiv Detail & Related papers (2020-05-06T09:02:30Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.