ZACH-ViT: Regime-Dependent Inductive Bias in Compact Vision Transformers for Medical Imaging
- URL: http://arxiv.org/abs/2602.17929v1
- Date: Fri, 20 Feb 2026 01:38:59 GMT
- Title: ZACH-ViT: Regime-Dependent Inductive Bias in Compact Vision Transformers for Medical Imaging
- Abstract summary: ZACH-ViT is a compact Vision Transformer that removes both positional embeddings and the [token] token.<n>"Zero-token" specifically refers to removing the dedicated [NIST] aggregation token and positional embeddings.<n>ZACH-ViT achieves competitive performance while maintaining sub-second inference times.
- Score: 0.0
- License: http://creativecommons.org/licenses/by-nc-sa/4.0/
- Abstract: Vision Transformers rely on positional embeddings and class tokens that encode fixed spatial priors. While effective for natural images, these priors may hinder generalization when spatial layout is weakly informative or inconsistent, a frequent condition in medical imaging and edge-deployed clinical systems. We introduce ZACH-ViT (Zero-token Adaptive Compact Hierarchical Vision Transformer), a compact Vision Transformer that removes both positional embeddings and the [CLS] token, achieving permutation invariance through global average pooling over patch representations. The term "Zero-token" specifically refers to removing the dedicated [CLS] aggregation token and positional embeddings; patch tokens remain unchanged and are processed normally. Adaptive residual projections preserve training stability in compact configurations while maintaining a strict parameter budget. Evaluation is performed across seven MedMNIST datasets spanning binary and multi-class tasks under a strict few-shot protocol (50 samples per class, fixed hyperparameters, five random seeds). The empirical analysis demonstrates regime-dependent behavior: ZACH-ViT (0.25M parameters, trained from scratch) achieves its strongest advantage on BloodMNIST and remains competitive with TransMIL on PathMNIST, while its relative advantage decreases on datasets with strong anatomical priors (OCTMNIST, OrganAMNIST), consistent with the architectural hypothesis. These findings support the view that aligning architectural inductive bias with data structure can be more important than pursuing universal benchmark dominance. Despite its minimal size and lack of pretraining, ZACH-ViT achieves competitive performance while maintaining sub-second inference times, supporting deployment in resource-constrained clinical environments. Code and models are available at https://github.com/Bluesman79/ZACH-ViT.
Related papers
- Rank-Aware Hyperbolic Alignment for Vision-Language Dataset Distillation [54.74045834035952]
Vision-language dataset distillation (VLDD) compresses a large image-text paired dataset into a small set of synthetic pairs.<n>We propose a rank-aware hyperbolic alignment (RAHA) that combines hierarchical geometry with explicit alignment-capacity control.<n>RAHA demonstrates competitive cross-modal retrieval and improved transfer indicators under fixed budgets.
arXiv Detail & Related papers (2026-06-28T15:41:31Z) - Shift-Dependent Asymmetry: Orthogonal Inverse Low-Rank Adaptation for Federated Medical Segmentation [60.41721951405564]
Low-Rank Adaptation (LoRA) enables efficient federated fine-tuning of segmentation foundation models for medical imaging.<n>Most federated LoRA methods adopt a uniform aggregation rule, which breaks under the encoder-decoder asymmetry in medical segmentation.<n>This mismatch entangles shared anatomy with site-specific biases and harms generalization.<n>We introduce a Subspace Orthogonality Regularizer that penalizes shared-local collinearity in the effective update space.
arXiv Detail & Related papers (2026-06-07T15:39:28Z) - Hierarchical Consistency Learning for Test-time Adaptation in Camouflage Perception [50.278200968044665]
Camouflaged object detection (COD) aims to localize targets that exhibit minimal perceptual differences from backgrounds through physical attributes.<n>Existing methods, constrained by the static train-then-freeze paradigm, suffer from domain rigidity and dependency annotation.<n>We propose the hierarchical consistency learning framework, which integrates test-time adaptation for dynamic representation recalibration.
arXiv Detail & Related papers (2026-05-25T09:57:46Z) - Rethink MAE with Linear Time-Invariant Dynamics [0.0]
We show that token order is a critical, exploitable dimension in frozen visual representations.<n>We propose SSMProbe, a probing framework driven by a State Space Model.
arXiv Detail & Related papers (2026-04-29T15:07:00Z) - Extending ZACH-ViT to Robust Medical Imaging: Corruption and Adversarial Stress Testing in Low-Data Regimes [0.23166812624868952]
ZACH-ViT (Zero-token Adaptive Compact Hierarchical Vision Transformer) formalized a compact permutation-invariant Vision Transformer for medical imaging.<n>We present the first robustness-focused extension of ZACH-ViT by evaluating its behavior under common image corruptions and adversarial perturbations.
arXiv Detail & Related papers (2026-04-07T17:11:07Z) - STRAP-ViT: Segregated Tokens with Randomized -- Transformations for Defense against Adversarial Patches in ViTs [2.458848206334729]
Adversarial patches are physically realizable localized noise, which are able to hijack Vision Transformers (ViT) self-attention.<n>We propose a mechanism, called STRAP-ViT, which uses Jensen-Shannon Divergence as a metric for segregating tokens that behave as anomalies.<n> STRAP-ViT fits as a non-trainable plug-and-play block within the ViT architectures, for inference purposes only, with a minimal computational cost.
arXiv Detail & Related papers (2026-03-13T06:03:44Z) - SPEGC: Continual Test-Time Adaptation via Semantic-Prompt-Enhanced Graph Clustering for Medical Image Segmentation [12.0982298854338]
Continual Test-Time Adaptation (CTTA) aims to enable pre-trained models to adapt to continuously changing unlabeled domains.<n>We propose a CTTA via Semantic-Prompt-Enhanced Graph Clustering (SPEGC) for medical image segmentation.
arXiv Detail & Related papers (2026-03-12T03:22:43Z) - Gated Differential Linear Attention: A Linear-Time Decoder for High-Fidelity Medical Segmentation [15.30336007288786]
PVT-GDLA is a decoder-centric Transformer that restores sharp, long-range dependencies at linear time.<n>It achieves state-of-the-art accuracy across CT, MRI, ultrasound, and dermoscopy benchmarks under equal training budgets.
arXiv Detail & Related papers (2026-03-03T08:26:08Z) - Fake It Right: Injecting Anatomical Logic into Synthetic Supervised Pre-training for Medical Segmentation [21.75204301463342]
Vision Transformers (ViTs) excel in 3D medical segmentation but require massive datasets.<n>Formula-Driven Supervised Learning (F) offers a privacy-preserving alternative by pre-training on synthetic mathematical primitives.<n>We propose an annotated-Informed Synthetic Anatomy Supervised Pre-training framework unifying F's infinite scalability with anatomical realism.
arXiv Detail & Related papers (2026-03-01T08:15:18Z) - LATA: Laplacian-Assisted Transductive Adaptation for Conformal Uncertainty in Medical VLMs [61.06744611795341]
Medical vision-language models (VLMs) are strong zero-shot recognizers for medical imaging.<n>We propose texttttextbfLATA (Laplacian-Assisted Transductive Adaptation), a textittraining- and label-free refinement.<n>texttttextbfLATA sharpens zero-shot predictions without compromising exchangeability.
arXiv Detail & Related papers (2026-02-19T16:45:38Z) - When Swin Transformer Meets KANs: An Improved Transformer Architecture for Medical Image Segmentation [10.656996937993199]
We introduce UKAST, a U-Net like architecture that integrates rational-function based Kolmogorov-Arnold Networks (KANs) into Swin Transformer encoders.<n>UKAST achieves state-of-the-art performance on four diverse 2D and 3D medical image segmentation benchmarks.
arXiv Detail & Related papers (2025-11-06T05:44:57Z) - CoMViT: An Efficient Vision Backbone for Supervised Classification in Medical Imaging [0.3683202928838613]
CoMViT is a compact and generalizable Vision Transformer architecture optimized for resource-constrained medical image analysis.<n>It achieves robust performance across twelve MedMNIST datasets while maintaining a lightweight design with only 4.5M parameters.
arXiv Detail & Related papers (2025-10-31T12:49:13Z) - Enhancing CLIP Robustness via Cross-Modality Alignment [54.01929554563447]
We propose Cross-modality Alignment, an optimal transport-based framework for vision-language models.<n> COLA restores global image-text alignment and local structural consistency in the feature space.<n> COLA is training-free and compatible with existing fine-tuned models.
arXiv Detail & Related papers (2025-10-28T03:47:44Z) - Knowledge-Informed Neural Network for Complex-Valued SAR Image Recognition [51.03674130115878]
We introduce the Knowledge-Informed Neural Network (KINN), a lightweight framework built upon a novel "compression-aggregation-compression" architecture.<n>KINN establishes a state-of-the-art in parameter-efficient recognition, offering exceptional generalization in data-scarce and out-of-distribution scenarios.
arXiv Detail & Related papers (2025-10-23T07:12:26Z) - The 1st Solution for CARE Liver Task Challenge 2025: Contrast-Aware Semi-Supervised Segmentation with Domain Generalization and Test-Time Adaptation [23.156209918252838]
CoSSeg-TTA is a compact segmentation framework for the GED4 (Gd-EOB-DTPA enhanced hepatobiliary phase MRI) modality built upon nnU-Netv2.<n>A domain adaptation module, incorporating a randomized histogram-based style appearance transfer function and a trainable contrast-aware network, enriches domain diversity and mitigates cross-center variability.
arXiv Detail & Related papers (2025-10-05T15:18:53Z) - BATR-FST: Bi-Level Adaptive Token Refinement for Few-Shot Transformers [2.5680214354539803]
We propose Bi-Level Adaptive Token Refinement for Few-Shot Transformers (BATR-FST)<n>BATR-FST progressively improves token representations and maintains a robust inductive bias for few-shot classification.<n>It achieves superior results in both 1-shot and 5-shot scenarios and improves the few-shot classification via transformers.
arXiv Detail & Related papers (2025-09-16T07:33:21Z) - Decoupling Clinical and Class-Agnostic Features for Reliable Few-Shot Adaptation under Shift [12.373281238541296]
Medical vision-language models (VLMs) offer promise for clinical decision support, yet their reliability under distribution shifts remains a major concern for safe deployment.<n>We propose DRiFt, a structured feature decoupling framework that explicitly separates clinically relevant signals from task-agnostic noise.<n>Our approach improves in-distribution performance by +11.4% Top-1 accuracy and +3.3% Macro-F1 over prior prompt-based methods.
arXiv Detail & Related papers (2025-09-11T12:26:57Z) - Towards Continual Learning Desiderata via HSIC-Bottleneck
Orthogonalization and Equiangular Embedding [55.107555305760954]
We propose a conceptually simple yet effective method that attributes forgetting to layer-wise parameter overwriting and the resulting decision boundary distortion.
Our method achieves competitive accuracy performance, even with absolute superiority of zero exemplar buffer and 1.02x the base model.
arXiv Detail & Related papers (2024-01-17T09:01:29Z) - UIA-ViT: Unsupervised Inconsistency-Aware Method based on Vision
Transformer for Face Forgery Detection [52.91782218300844]
We propose a novel Unsupervised Inconsistency-Aware method based on Vision Transformer, called UIA-ViT.
Due to the self-attention mechanism, the attention map among patch embeddings naturally represents the consistency relation, making the vision Transformer suitable for the consistency representation learning.
arXiv Detail & Related papers (2022-10-23T15:24:47Z) - nnFormer: Interleaved Transformer for Volumetric Segmentation [50.10441845967601]
We introduce nnFormer, a powerful segmentation model with an interleaved architecture based on empirical combination of self-attention and convolution.
nnFormer achieves tremendous improvements over previous transformer-based methods on two commonly used datasets Synapse and ACDC.
arXiv Detail & Related papers (2021-09-07T17:08:24Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.