CT-Enabled Patient-Specific Simulation and Contact-Aware Robotic Planning for Cochlear Implantation
- URL: http://arxiv.org/abs/2603.05333v1
- Date: Thu, 05 Mar 2026 16:13:59 GMT
- Title: CT-Enabled Patient-Specific Simulation and Contact-Aware Robotic Planning for Cochlear Implantation
- Abstract summary: Robotic cochlear-implant insertion requires precise prediction and regulation of contact forces to minimize intracochlear trauma.<n>This paper presents a unified CT-to-simulation pipeline for contact-aware insertion planning and validation.
- Score: 41.386729124620366
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Robotic cochlear-implant (CI) insertion requires precise prediction and regulation of contact forces to minimize intracochlear trauma and prevent failure modes such as locking and buckling. Aligned with the integration of advanced medical imaging and robotics for autonomous, precision interventions, this paper presents a unified CT-to-simulation pipeline for contact-aware insertion planning and validation. We develop a low-dimensional, differentiable Cosserat-rod model of the electrode array coupled with frictional contact and pseudo-dynamics regularization to ensure continuous stick-slip transitions. Patient-specific cochlear anatomy is reconstructed from CT imaging and encoded via an analytic parametrization of the scala-tympani lumen, enabling efficient and differentiable contact queries through closest-point projection. Based on a differentiated equilibrium-constraint formulation, we derive an online direction-update law under an RCM-like constraint that suppresses lateral insertion forces while maintaining axial advancement. Simulations and benchtop experiments validate deformation and force trends, demonstrating reduced locking/buckling risk and improved insertion depth. The study highlights how CT-based imaging enhances modeling, planning, and safety capabilities in robot-assisted inner-ear procedures.
Related papers
- Seeing Through Occlusion: Deterministic Arm Kinematic Correction for Robot Teleoperation [6.979012378888037]
This paper presents an Arm Kinematic Correction (AKC) method that improves depth estimation by enforcing geometric constraints based on constant arm lengths.<n> Experimental validation against a Vicon reference system demonstrates reliable performance for both static and dynamic joint motions.<n>The results show that AKC enhances robustness and preserves anatomical consistency under long-duration, severe self-occlusion, even when paired with less reliable temporal filters.
arXiv Detail & Related papers (2026-06-17T16:20:10Z) - 3D Ultrasound-Derived Pseudo-CT Synthesis Using a Transformer-Augmented Residual Network for Real-Time Operator Guidance [0.0]
Ultrasound (US) is non-ionizing and widely accessible; however, it is highly operator dependent and lacks quantitative tissue characterization.<n>This work presents a 3D ultrasound-derived pseudo-CT framework that generates CT-like anatomical reference volumes inferred from US.<n>The proposed method outperforms established baselines in structural fidelity and perceptual image quality.
arXiv Detail & Related papers (2026-05-06T12:52:59Z) - PHASOR: Anatomy- and Phase-Consistent Volumetric Diffusion for CT Virtual Contrast Enhancement [60.81732730684265]
This paper introduces PHASOR, a volumetric diffusion framework for high-fidelity virtual contrast enhancement (VCE)<n>By treating CT volumes as coherent sequences, we leverage a video diffusion model to enhance structural coherence and volumetric accuracy.<n>To ensure anatomy-phase consistent synthesis, we introduce two complementary modules. First, anatomy-routed mixture-of-experts (AR-MoE) anchors distinct enhancement patterns to anatomical semantics, with organ-specific memory to capture salient details.<n>Second, intensity-phase aware representation alignment (IP-REPA) highlights intricate contrast signals while mitigating the impact of imperfect spatial alignment.
arXiv Detail & Related papers (2026-04-01T15:57:18Z) - Adaptive Manipulation Potential and Haptic Estimation for Tool-Mediated Interaction [14.888648782445694]
This paper introduces a parameterized Equilibrium Manifold (EM) as a unified representation for tool-mediated interaction.<n>We develop a closed-loop framework that integrates haptic estimation, online planning, and adaptive stiffness control.<n>The framework is validated through simulation and over 260 real-world screw-loosening trials.
arXiv Detail & Related papers (2026-03-11T02:57:55Z) - Robotic Ultrasound Makes CBCT Alive [40.80821441492365]
Intraoperative Cone Beam Computed Tomography (CBCT) provides a reliable 3D anatomical context essential for interventional planning.<n>We propose a deformation-aware CBCT updating framework that leverages robotic ultrasound as a dynamic proxy to infer tissue motion and update static CBCT slices in real time.<n>Results demonstrate real-time end-to-end CBCT slice updating and physically plausible deformation estimation, enabling dynamic refinement of static CBCT guidance during robotic ultrasound-assisted interventions.
arXiv Detail & Related papers (2026-03-10T20:37:24Z) - Preoperative-to-intraoperative Liver Registration for Laparoscopic Surgery via Latent-Grounded Correspondence Constraints [51.7011449975586]
Land-Reg is a deformable registration framework that learns latent-grounded 2D-3D landmark correspondences.<n>For rigid registration, Land-Reg embraces a Cross-modal Latent Alignment module.<n>An Uncertainty-enhanced Overlap Landmark Detector with similarity matching is proposed to robustly estimate explicit 2D-3D landmark correspondences.
arXiv Detail & Related papers (2026-03-02T10:44:03Z) - Toward Reliable AR-Guided Surgical Navigation: Interactive Deformation Modeling with Data-Driven Biomechanics and Prompts [21.952265898720825]
We propose a data-driven algorithm that preserves FEM-level accuracy while improving computational efficiency.<n>We introduce a novel human-in-the-loop mechanism into the deformation modeling process.<n>Our algorithm achieves a mean target registration error of 3.42 mm, surpassing state-of-the-art methods in volumetric accuracy.
arXiv Detail & Related papers (2025-06-08T14:19:54Z) - Federated Learning for Coronary Artery Plaque Detection in Atherosclerosis Using IVUS Imaging: A Multi-Hospital Collaboration [8.358846277772779]
Traditional interpretation of Intravascular Ultrasound (IVUS) images during Percutaneous Coronary Intervention ( PCI) is time-intensive and inconsistent.<n>A parallel 2D U-Net model with a multi-stage segmentation architecture has been developed to enable secure data analysis across institutions.<n>A Dice Similarity Coefficient (DSC) of 0.706, the model effectively identifies plaques and detects circular boundaries in real-time.
arXiv Detail & Related papers (2024-12-19T13:06:28Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - Robotic Navigation Autonomy for Subretinal Injection via Intelligent
Real-Time Virtual iOCT Volume Slicing [88.99939660183881]
We propose a framework for autonomous robotic navigation for subretinal injection.
Our method consists of an instrument pose estimation method, an online registration between the robotic and the i OCT system, and trajectory planning tailored for navigation to an injection target.
Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method.
arXiv Detail & Related papers (2023-01-17T21:41:21Z) - Real-time landmark detection for precise endoscopic submucosal
dissection via shape-aware relation network [51.44506007844284]
We propose a shape-aware relation network for accurate and real-time landmark detection in endoscopic submucosal dissection surgery.
We first devise an algorithm to automatically generate relation keypoint heatmaps, which intuitively represent the prior knowledge of spatial relations among landmarks.
We then develop two complementary regularization schemes to progressively incorporate the prior knowledge into the training process.
arXiv Detail & Related papers (2021-11-08T07:57:30Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.