AI End-to-End Radiation Treatment Planning Under One Second
- URL: http://arxiv.org/abs/2603.06338v1
- Date: Fri, 06 Mar 2026 14:45:44 GMT
- Title: AI End-to-End Radiation Treatment Planning Under One Second
- Abstract summary: We introduce AIRT (Artificial Intelligence-based Radiotherapy), an end-to-end deep-learning framework that directly infers deliverable treatment plans from CT images and structure contours.<n>AIRT generates single-arc VMAT prostate plans, from imaging and anatomical inputs to leaf sequencing, in under one second on a single Nvidia A100 GPU.<n>Non-inferiority to RapidPlan Eclipse was demonstrated across target coverage and OAR sparing metrics.
- Score: 3.908966856945294
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Artificial intelligence-based radiation therapy (RT) planning has the potential to reduce planning time and inter-planner variability, improving efficiency and consistency in clinical workflows. Most existing automated approaches rely on multiple dose evaluations and corrections, resulting in plan generation times of several minutes. We introduce AIRT (Artificial Intelligence-based Radiotherapy), an end-to-end deep-learning framework that directly infers deliverable treatment plans from CT images and structure contours. AIRT generates single-arc VMAT prostate plans, from imaging and anatomical inputs to leaf sequencing, in under one second on a single Nvidia A100 GPU. The framework includes a differentiable dose feedback, an adversarial fluence map shaping, and a plan generation augmentation to improve plan quality and robustness. The model was trained on more than 10,000 intact prostate cases. Non-inferiority to RapidPlan Eclipse was demonstrated across target coverage and OAR sparing metrics. Target homogeneity (HI = 0.10 $\pm$ 0.01) and OAR sparing were similar to reference plans when evaluated using AcurosXB. These results represent a significant step toward ultra-fast standardized RT planning and a streamlined clinical workflow.
Related papers
- Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning [0.0]
Dose-PlanNet is a physics-guided 3D deep learning architecture designed to predict dose distributions.<n>This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.
arXiv Detail & Related papers (2026-08-27T10:05:01Z) - A DeepSeek-Powered AI System for Automated Chest Radiograph Interpretation in Clinical Practice [83.11942224668127]
Janus-Pro-CXR (1B) is a chest X-ray interpretation system based on DeepSeek Janus-Pro model.<n>Our system outperforms state-of-the-art X-ray report generation models in automated report generation.
arXiv Detail & Related papers (2025-12-23T13:26:13Z) - Fluence Map Prediction with Deep Learning: A Transformer-based Approach [4.362977319915193]
This study presents a deep learning framework that accelerates fluence map generation while maintaining clinical quality.<n>An end-to-end 3D Swin-UNETR network was trained to predict nine-beam fluence maps directly from volumetric CT images and anatomical contours.<n>The proposed model achieved an average R2 of 0.95 +/- 0.02, MAE of 0.035 +/- 0.008, and gamma passing rate of 85 +/- 10 percent (3 percent / 3 mm) on the test set.
arXiv Detail & Related papers (2025-11-10T19:24:14Z) - Design and Validation of a Responsible Artificial Intelligence-based System for the Referral of Diabetic Retinopathy Patients [65.57160385098935]
Early detection of Diabetic Retinopathy can reduce the risk of vision loss by up to 95%.<n>We developed RAIS-DR, a Responsible AI System for DR screening that incorporates ethical principles across the AI lifecycle.<n>We evaluated RAIS-DR against the FDA-approved EyeArt system on a local dataset of 1,046 patients, unseen by both systems.
arXiv Detail & Related papers (2025-08-17T21:54:11Z) - Automated Treatment Planning for Interstitial HDR Brachytherapy for Locally Advanced Cervical Cancer using Deep Reinforcement Learning [3.9838929530763076]
The objective of this study is to develop a fully automated HDR brachytherapy planning framework.<n>We propose a hierarchical two-stage autoplanning framework.<n>For the unseen test patients, the RL-based automated planning method achieved an average score of 93.89%, outperforming the clinical plans which averaged 91.86%.
arXiv Detail & Related papers (2025-06-13T17:07:30Z) - Automating RT Planning at Scale: High Quality Data For AI Training [6.8532126457187035]
We introduce the Automated Iterative RT Planning (AIRTP) system, a scalable solution for generating high-quality treatment plans.<n>Our AIRTP pipeline adheres to clinical guidelines and automates essential steps, including organ-at-risk (OAR) contouring, helper structure creation, beam setup, optimization, and plan quality improvement.<n>A comparative analysis of plan quality reveals that our automated pipeline produces treatment plans of quality comparable to those generated manually.
arXiv Detail & Related papers (2025-01-21T00:44:18Z) - Neural LerPlane Representations for Fast 4D Reconstruction of Deformable
Tissues [52.886545681833596]
LerPlane is a novel method for fast and accurate reconstruction of surgical scenes under a single-viewpoint setting.
LerPlane treats surgical procedures as 4D volumes and factorizes them into explicit 2D planes of static and dynamic fields.
LerPlane shares static fields, significantly reducing the workload of dynamic tissue modeling.
arXiv Detail & Related papers (2023-05-31T14:38:35Z) - Robotic Navigation Autonomy for Subretinal Injection via Intelligent
Real-Time Virtual iOCT Volume Slicing [88.99939660183881]
We propose a framework for autonomous robotic navigation for subretinal injection.
Our method consists of an instrument pose estimation method, an online registration between the robotic and the i OCT system, and trajectory planning tailored for navigation to an injection target.
Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method.
arXiv Detail & Related papers (2023-01-17T21:41:21Z) - Robust and Efficient Medical Imaging with Self-Supervision [80.62711706785834]
We present REMEDIS, a unified representation learning strategy to improve robustness and data-efficiency of medical imaging AI.
We study a diverse range of medical imaging tasks and simulate three realistic application scenarios using retrospective data.
arXiv Detail & Related papers (2022-05-19T17:34:18Z) - A feasibility study of a hyperparameter tuning approach to automated
inverse planning in radiotherapy [68.8204255655161]
The purpose of this study is to automate the inverse planning process to reduce active planning time while maintaining plan quality.
We investigated the impact of the choice of dose parameters, random and Bayesian search methods, and utility function form on planning time and plan quality.
Using 100 samples was found to produce satisfactory plan quality, and the average planning time was 2.3 hours.
arXiv Detail & Related papers (2021-05-14T18:37:00Z) - Rapid treatment planning for low-dose-rate prostate brachytherapy with
TP-GAN [9.064664319018064]
Treatment planning in low-dose-rate prostate brachytherapy (LDR-PB) aims to produce arrangement of implantable radioactive seeds that deliver a minimum prescribed dose to the prostate.
There can be multiple seed arrangements that satisfy this dosimetric criterion, not all deemed 'acceptable' for implant from a physician's perspective.
We propose a method that aims to reduce this variability by training a model to learn from a large pool of successful retrospective LDR-PB data.
arXiv Detail & Related papers (2021-03-18T03:02:45Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.