Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables
- URL: http://arxiv.org/abs/2605.17859v2
- Date: Tue, 19 May 2026 03:42:45 GMT
- Title: Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables
- Abstract summary: We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed wearables.<n>Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment.<n>Participants wore the devices for multiple days during daytime activities while continuing their normal routines.
- Score: 8.222135147118921
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Wearables are widely used for mobile health monitoring, and photoplethysmography (PPG) is a key sensing modality for heart rate and related physiological measurements. However, public in-the-wild PPG datasets remain largely wrist-centric or limited to short, controlled studies, constraining research on emerging wearable form factors. We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed unobtrusive wearables: a smart earring, ring, watch, and necklace. Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment, while a Polar H10 chest strap provides reference electrocardiogram (ECG). Participants wore the devices for multiple days during daytime activities while continuing their normal routines. The dataset contains over 350 hours of raw data and 230-290 hours of modeling-ready 8-second windows per wearable. We benchmark heuristic, supervised, and self-supervised heart-rate estimation methods, showing substantial body-site differences: the best methods achieve mean absolute errors (MAEs) of 2.30 bpm on the earring, 5.13 bpm on the ring, 8.37 bpm on the watch, and 8.68 bpm on the necklace. We further analyze motion effects and evaluate multi-site and PPG-accelerometer fusion, demonstrating the dataset's value for robust physiological sensing across emerging wearable form factors.
Related papers
- Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU [44.313512671851306]
False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units.<n>We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task.
arXiv Detail & Related papers (2026-09-08T16:33:07Z) - PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation [40.05930520726773]
Photoplethys enables non-contact heart-rate estimation from facial videos.<n>Current methods rely on a single model to directly predict heart rate or pulse waveforms.<n>We propose PhysAgent, an inference-time multi-agent model.
arXiv Detail & Related papers (2026-07-29T02:49:24Z) - CoDaS: AI Co-Data-Scientist for Biomarker Discovery via Wearable Sensors [44.01195029438923]
We introduce CoDaS (AI Co-Data-Scientist), a system that structures biomarker discovery as an iterative process.<n>Across three cohorts totaling 9,279 participantobservations, CoDaS identified 41 candidate digital for mental health and 25 for metabolic outcomes.<n>CoDaS surfaced circadian instability-related features in both datasets reflected in sleep duration variability.
arXiv Detail & Related papers (2026-04-16T04:47:55Z) - Detection of Autonomic Dysreflexia in Individuals With Spinal Cord Injury Using Multimodal Wearable Sensors [2.208475400165877]
Autonomic Dysreflexia (AD) is a potentially life-threatening condition characterized by sudden, severe blood pressure spikes in individuals with spinal cord injury (SCI)<n>This study presents a non-invasive, explainable machine learning framework for detecting AD using multimodal wearable sensors.
arXiv Detail & Related papers (2025-07-23T21:18:23Z) - TAU: Modeling Temporal Consistency Through Temporal Attentive U-Net for PPG Peak Detection [1.9518933807303265]
Photoplethysmography ( PPG) sensors have been widely used in consumer wearable devices to monitor heart rates (HR) and heart rate variability (HRV)<n>Despite the prevalence, PPG signals can be contaminated by motion artifacts induced from daily activities.<n>We propose the Temporal Attentive U-Net, i.e., TAU, to accurately detect peaks from PPG signals.
arXiv Detail & Related papers (2025-03-13T14:45:08Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [46.36100528165335]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - WildPPG: A Real-World PPG Dataset of Long Continuous Recordings [22.626523728464615]
We show that state-of-the-art HR estimation methods struggle when processing emphrepresentative data from everyday activities in outdoor environments.<n>We introduce a novel multimodal dataset and benchmark results for continuous PPG recordings during outdoor activities from 16 participants over 13.5 hours.<n>We present a novel method that estimates HR values more robustly in such real-world scenarios than existing baselines.
arXiv Detail & Related papers (2024-12-23T13:02:45Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - Quality Assessment of Photoplethysmography Signals For Cardiovascular
Biomarkers Monitoring Using Wearable Devices [0.0]
Photoplethysmography is a non-invasive technology that measures changes in blood volume in the microvascular bed of tissue.
Photoplethysmography allows for the assessment of parameters that can indicate conditions such as vasoconstriction or vasodilation.
arXiv Detail & Related papers (2023-07-17T18:26:57Z) - Real-time Webcam Heart-Rate and Variability Estimation with Clean Ground
Truth for Evaluation [9.883261192383612]
Remote photo-plethysmography (r) uses a camera to estimate a person's heart rate (HR)
HRV is a measure of the fine fluctuations in the intervals between heart beats.
We introduce a refined and efficient real-time r pipeline with novel filtering and motion suppression.
arXiv Detail & Related papers (2020-12-31T18:57:05Z) - Video-based Remote Physiological Measurement via Cross-verified Feature
Disentangling [121.50704279659253]
We propose a cross-verified feature disentangling strategy to disentangle the physiological features with non-physiological representations.
We then use the distilled physiological features for robust multi-task physiological measurements.
The disentangled features are finally used for the joint prediction of multiple physiological signals like average HR values and r signals.
arXiv Detail & Related papers (2020-07-16T09:39:17Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.