Vector Magnetometry with Broadband Microwave Fields in Nitrogen-Vacancy Centers in Diamond
- URL: http://arxiv.org/abs/2606.02749v1
- Date: Mon, 01 Jun 2026 18:13:22 GMT
- Title: Vector Magnetometry with Broadband Microwave Fields in Nitrogen-Vacancy Centers in Diamond
- Abstract summary: We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers.<n>In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses.<n>Our method yields sensitivities between $5mathrmpT/sqrtmathrmHz$ and $100mathrmpT/sqrtmathrmHz$ across different magnetic field vector components.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between $5~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ and $100~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ across different magnetic field vector components, while achieving approximately $\mathrm{nT}$ accuracy at a signal-to-noise (SNR) ratio of $70~\mathrm{dB}$. By being capable of accurately measuring magnetic fields down to $25~\mathrm{μT}$, the need for a bias field beyond Earth's magnetic field is eliminated.
Related papers
- Room-temperature inversionless diamond nitrogen-vacancy electronic spin maser [0.0]
We propose a room-temperature maser operating at approximately 2.9GHz frequency using an ensemble of negatively charged nitrogen-vacancy electronic spins in diamond.<n>Our method considers a DC magnetic field of a few milli-Tesla applied along the perpendicular direction of an ensemble of NV spins aligned along a common axis.<n>We show that the output intensity of an inversionless maser ($1.1times1014$ spins) can be used for magnetic field sensing with a DC sensitivity on the order of a hundred pT/$sqrtmathrmHz$.
arXiv Detail & Related papers (2026-07-08T08:06:30Z) - Using NV centers in diamond to detect DC to very-low frequency magnetic fields [0.0]
We present a compact and portable tabletop magnetometer that utilizes negatively charged nitrogen-vacancy centers in diamond.<n>The experimentally measured magnetic field noise-floor is $approx 2.3textrmnTsqrttextrmHz$ while the calculated shot-noise-limited magnetic field sensitivity is $approx 585textrmpTsqrttextrmHz$ when excited with a continuous wave laser at 0.5W.
arXiv Detail & Related papers (2025-12-30T14:57:37Z) - Robust AC vector sensing at zero magnetic field with pentacene [45.7221176995052]
Quantum sensors based on electronic spins have emerged as powerful probes of microwave-frequency fields.<n>Here, we demonstrate microwave vector magnetometry using the photoexcited spin triplet of pentacene molecules.
arXiv Detail & Related papers (2025-12-06T03:49:12Z) - Optimal and efficient inference tools for field tracking with precessing spins [35.18016233072556]
Spin-precession magnetometer (SPM) observes electron, nucleus, color center, or muon spins as they precess in response to their local magnetic field.<n>We show that it is sufficient to accurately track fluctuating and unknown transient signals.<n>Our methods can be easily adapted to other types of sensors undergoing nonlinear dissipative dynamics.
arXiv Detail & Related papers (2025-10-13T19:44:33Z) - Magnetometry with Broadband Microwave Fields in Nitrogen-Vacancy Centers in Diamond [0.0]
Nitrogen vacancy (NV) centers in diamond are optically addressable and versatile light-matter interfaces.<n>We propose an approach to simultaneously probe all of the magnetically sensitive states using a broadband microwave field.
arXiv Detail & Related papers (2025-09-29T18:18:00Z) - Bias-field-free operation of nitrogen-vacancy ensembles in diamond for accurate vector magnetometry [0.0]
Nitrogen-vacancy center spin ensembles offer a promising solution for high-sensitivity vector magnetometry.<n> bias magnetic field typically used to separate signals from each NV orientation introduces inaccuracy from drifts in permanent magnets or coils.<n>We present a novel bias-field-free approach that labels the NV orientations via the direction of the microwave (MW) field in a variable-pulse-duration Ramsey sequence.
arXiv Detail & Related papers (2025-05-30T13:26:10Z) - Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond [0.0]
Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications.
NV center magnetometry has emerged as an ideal tool, offering $mu$m-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples.
This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields.
arXiv Detail & Related papers (2024-09-25T00:38:13Z) - Vector Magnetometry Using Shallow Implanted NV Centers in Diamond with Waveguide-Assisted Dipole Excitation and Readout [33.221915954445855]
Nitrogen-Vacancy (NV) centers in diamond require scalable integration of 3D waveguides into diamond substrates.<n>We develop a sensing array device with an ensemble of shallow implanted NV centers integrated with arrays of laser-written waveguides for excitation and readout of NV signals.
arXiv Detail & Related papers (2024-07-26T12:55:25Z) - Magnetic-field-independent spin-exchange relaxation-free magnetometer [0.0]
We show that atoms with nuclear spin $I=1/2$ can operate in the Spin-Exchange Relaxation Free regime even at high magnetic field.<n>We analyze the performance of a dual-specie potassium and atomic hydrogen magnetometer, and project a fundamental sensitivity of about $10.
arXiv Detail & Related papers (2022-09-27T00:36:02Z) - Physics-informed compressed sensing for PC-MRI: an inverse Navier-Stokes
problem [78.20667552233989]
We formulate a physics-informed compressed sensing (PICS) method for the reconstruction of velocity fields from noisy and sparse magnetic resonance signals.
We find that the method is capable of reconstructing and segmenting the velocity fields from sparsely-sampled signals.
arXiv Detail & Related papers (2022-07-04T14:51:59Z) - Multi-Center Magnon Excitations Open the Entire Brillouin Zone to
Terahertz Magnetometry of Quantum Magnets [42.72559625804617]
The magnon density of states can be accessed over the entire Brillouin zone through three-center magnon excitations.
The results of THz time-domain experiments agree remarkably well with linear spin-wave theory.
arXiv Detail & Related papers (2022-03-08T19:04:24Z) - Optimal coupling of HoW$_{10}$ molecular magnets to superconducting
circuits near spin clock transitions [85.83811987257297]
We study the coupling of pure and magnetically diluted crystals of HoW$_10$ magnetic clusters to microwave superconducting coplanar waveguides.
Results show that engineering spin-clock states of molecular systems offers a promising strategy to combine sizeable spin-photon interactions with a sufficient isolation from unwanted magnetic noise sources.
arXiv Detail & Related papers (2019-11-18T11:03:06Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.