Three-Dimensional Retinal Microvasculature Restoration in OCT Angiography
- URL: http://arxiv.org/abs/2606.05375v1
- Date: Wed, 03 Jun 2026 19:23:09 GMT
- Title: Three-Dimensional Retinal Microvasculature Restoration in OCT Angiography
- Abstract summary: We propose a deep learning algorithm for restoring anatomical vasculature from a single OCTA volume.<n>The proposed model significantly improved image quality compared with the original single OCTA volume.
- Score: 4.442929593591647
- License: http://creativecommons.org/licenses/by-nc-nd/4.0/
- Abstract: Optical coherence tomographic angiography (OCTA) is a powerful technique for imaging retinal microvasculature. However, acquiring reliable quantification of retinal blood flow and areas of retinal nonperfusion is challenging because of imaging artifacts. Existing methods primarily focus on noise suppression, projection artifact removal, or signal enhancement to improve the image quality of OCTA in cross-sectional or two-dimensional (2D) en face projections, while neglecting the intrinsic three-dimensional vascular architecture. In this study, we propose a deep learning-based algorithm for restoring capillary anatomical vasculature from a single OCTA volume. The network consists of an EfficientNet-B5 encoder and a decoder incorporating concurrent spatial and channel squeeze-and-excitation modules, connected via skip connections to preserve spatial resolution. Three adjacent B-frames are used as input to predict the restored middle B-frame. We evaluated the performance of the model using the peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) against ground truth generated from averaging multiple scans. The results show that the proposed model significantly (both p < 0.001) improved image quality compared with the original single OCTA volume, with a PSNR of 26.16 +/- 1.26 vs. 22.23 +/- 0.78 and an SSIM of 0.91 +/- 0.02 vs. 0.72 +/- 0.03. The proposed model also significantly (p < 0.001) improved microvascular fidelity, measured by the Dice coefficient overlap between the model output and ground truth, in both 2D and 3D by at least 3.8% and 51.2%, respectively, across several different vascular slabs.
Related papers
- Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts [56.74856091904914]
We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction.<n>ScanCLIP derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features.<n>A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction.
arXiv Detail & Related papers (2026-05-29T02:48:23Z) - Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement [0.0]
We present an image-based harmonization framework for 3D T1-weighted brain MRI.<n>The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features.<n>Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings.
arXiv Detail & Related papers (2025-10-24T23:19:02Z) - An Efficient 3D Latent Diffusion Model for T1-contrast Enhanced MRI Generation [7.487974687364868]
Gadolinium-based contrast agents (GBCAs) are commonly employed with T1w MRI to enhance lesion visualization but are restricted in patients at risk of nephrogenic systemic fibrosis.<n>This study develops a 3D deep-learning framework to generate T1-contrast enhanced images (T1C) from pre-contrast multiparametric MRI.
arXiv Detail & Related papers (2025-09-29T02:22:55Z) - 3D Nephrographic Image Synthesis in CT Urography with the Diffusion Model and Swin Transformer [3.8557197729550485]
The proposed approach effectively synthesizes high-quality 3D nephrographic phase images.<n>It can be used to reduce radiation dose in CTU by 33.3% without compromising image quality.
arXiv Detail & Related papers (2025-02-26T23:22:31Z) - Weakly supervised segmentation of intracranial aneurysms using a novel 3D focal modulation UNet [0.5106162890866905]
We propose FocalSegNet, a novel 3D focal modulation UNet, to detect an aneurysm and offer an initial, coarse segmentation of it from time-of-flight MRA image patches.
We trained and evaluated our model on a public dataset, and in terms of UIA detection, our model showed a low false-positive rate of 0.21 and a high sensitivity of 0.80.
arXiv Detail & Related papers (2023-08-06T03:28:08Z) - Diffusion Models for Counterfactual Generation and Anomaly Detection in Brain Images [39.94162291765236]
We present a weakly supervised method to generate a healthy version of a diseased image and then use it to obtain a pixel-wise anomaly map.
We employ a diffusion model trained on healthy samples and combine Denoising Diffusion Probabilistic Model (DDPM) and Denoising Implicit Model (DDIM) at each step of the sampling process.
arXiv Detail & Related papers (2023-08-03T21:56:50Z) - Deep learning network to correct axial and coronal eye motion in 3D OCT
retinal imaging [65.47834983591957]
We propose deep learning based neural networks to correct axial and coronal motion artifacts in OCT based on a single scan.
The experimental result shows that the proposed method can effectively correct motion artifacts and achieve smaller error than other methods.
arXiv Detail & Related papers (2023-05-27T03:55:19Z) - Acute ischemic stroke lesion segmentation in non-contrast CT images
using 3D convolutional neural networks [0.0]
We propose an automatic algorithm aimed at volumetric segmentation of acute ischemic stroke lesion in non-contrast computed tomography brain 3D images.
Our deep-learning approach is based on the popular 3D U-Net convolutional neural network architecture.
arXiv Detail & Related papers (2023-01-17T10:39:39Z) - Affinity Feature Strengthening for Accurate, Complete and Robust Vessel
Segmentation [48.638327652506284]
Vessel segmentation is crucial in many medical image applications, such as detecting coronary stenoses, retinal vessel diseases and brain aneurysms.
We present a novel approach, the affinity feature strengthening network (AFN), which jointly models geometry and refines pixel-wise segmentation features using a contrast-insensitive, multiscale affinity approach.
arXiv Detail & Related papers (2022-11-12T05:39:17Z) - Negligible effect of brain MRI data preprocessing for tumor segmentation [36.89606202543839]
We conduct experiments on three publicly available datasets and evaluate the effect of different preprocessing steps in deep neural networks.
Our results demonstrate that most popular standardization steps add no value to the network performance.
We suggest that image intensity normalization approaches do not contribute to model accuracy because of the reduction of signal variance with image standardization.
arXiv Detail & Related papers (2022-04-11T17:29:36Z) - Deep Implicit Statistical Shape Models for 3D Medical Image Delineation [47.78425002879612]
3D delineation of anatomical structures is a cardinal goal in medical imaging analysis.
Prior to deep learning, statistical shape models that imposed anatomical constraints and produced high quality surfaces were a core technology.
We present deep implicit statistical shape models (DISSMs), a new approach to delineation that marries the representation power of CNNs with the robustness of SSMs.
arXiv Detail & Related papers (2021-04-07T01:15:06Z) - Revisiting 3D Context Modeling with Supervised Pre-training for
Universal Lesion Detection in CT Slices [48.85784310158493]
We propose a Modified Pseudo-3D Feature Pyramid Network (MP3D FPN) to efficiently extract 3D context enhanced 2D features for universal lesion detection in CT slices.
With the novel pre-training method, the proposed MP3D FPN achieves state-of-the-art detection performance on the DeepLesion dataset.
The proposed 3D pre-trained weights can potentially be used to boost the performance of other 3D medical image analysis tasks.
arXiv Detail & Related papers (2020-12-16T07:11:16Z) - OCT-GAN: Single Step Shadow and Noise Removal from Optical Coherence
Tomography Images of the Human Optic Nerve Head [47.812972855826985]
We developed a single process that successfully removed both noise and retinal shadows from unseen single-frame B-scans within 10.4ms.
The proposed algorithm reduces the necessity for long image acquisition times, minimizes expensive hardware requirements and reduces motion artifacts in OCT images.
arXiv Detail & Related papers (2020-10-06T08:32:32Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.