What neurosurgeons need to see: synthetic intra-operative MRI from ultrasound for brain-shift compensation in brain tumour surgery
- URL: http://arxiv.org/abs/2606.07658v1
- Date: Wed, 03 Jun 2026 11:17:47 GMT
- Title: What neurosurgeons need to see: synthetic intra-operative MRI from ultrasound for brain-shift compensation in brain tumour surgery
- Abstract summary: We propose an end-to-end pipeline that generates a new whole-brain MRI volume in the preoperative imaging space.<n>In 14 subjects with 215 expert landmarks, the synthesis-anchored registration reduced the mean target registration error.<n>This provides an MRI-like update of the operative field with potential for integration into surgical-navigation.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Maximal safe resection is the primary objective in glioma surgery. Neuronavigation guidance is progressively degraded by brain shift after dural opening. Intraoperative MRI can compensate but needs dedicated infrastructure and is rarely available, whereas intraoperative ultrasound (ioUS) is inexpensive, repeatable, and compatible with routine workflows. Navigation systems combining ioUS with preoperative MRI usually rely on rigid registration; even deformable multimodal registration is limited by ultrasound speckle contrast, a narrow field of view, and the inability to represent structures absent from the preoperative scan, most critically the resection cavity and residual tumor. We propose an end-to-end pipeline that generates a new whole-brain MRI volume in the preoperative imaging space by merging the preoperative MRI, a synthetic MRI generated from the ioUS, and a deformable registration anchored on that synthetic image. It integrates a 2.5D residual-transformer synthesis backbone (ResViT-2.5D) and a two-stage registration coupling NiftyReg with a synthesis-anchored SynthMorph stage, operating directly on raw scanner inputs. On a post-resection ReMIND cohort, ResViT-2.5D produced synthetic images closely matching the intraoperative T2 across structural, intensity, and perceptual metrics. In 14 subjects with 215 expert landmarks, the synthesis-anchored registration reduced the mean target registration error from 6.27 to 5.86 mm, matching a strong classical NiftyReg baseline (5.85 mm) while yielding a diffeomorphic deformation field in every subject. The contribution is not a gain in registration accuracy but the integrated volume itself, which inside the ultrasound field of view it reflects the intraoperative post-resection state. This provides the surgeon with an MRI-like update of the operative field with potential for integration into surgical-navigation workflows.
Related papers
- A Systematic Benchmark of Intraoperative Ultrasound-to-MR Synthesis for Brain Tumour Surgery [0.0]
Intraoperative ultrasound (ioUS) is a versatile, cost-effective modality in brain tumour surgery.<n>Most prior work evaluates a single architecture in isolation.<n>No benchmark has spanned architectural paradigms, inference regimes and downstream-task endpoints.
arXiv Detail & Related papers (2026-05-30T09:05:24Z) - AI Approach for MRI-only Full-Spine Vertebral Segmentation and 3D Reconstruction in Paediatric Scoliosis [0.0]
MRI is preferred over CT in paediatric imaging because it avoids ionising radiation.<n>Its use in spine deformity assessment is largely limited by the lack of automated, high-resolution 3D bony reconstruction.<n>This study introduces an AI framework that enables fully automated thoracolumbar spine (T1-L5) segmentation and 3D reconstruction from MRI alone.
arXiv Detail & Related papers (2026-04-20T05:57:06Z) - The Brain Resection Multimodal Image Registration (ReMIND2Reg) 2025 Challenge [42.51640997446028]
The ReMIND2Reg 2025 Challenge provides the largest public benchmark for this task, built upon the ReMIND dataset.<n>It offers 99 training cases, 5 validation cases, and 10 private test cases comprising paired 3D ceT1 MRI, T2 MRI, and post-resection 3D iUS volumes.<n>Data are provided without annotations for training, while validation and test performance are evaluated on manually annotated anatomical landmarks.
arXiv Detail & Related papers (2025-08-13T09:31:06Z) - Landmark-Free Preoperative-to-Intraoperative Registration in Laparoscopic Liver Resection [50.388465935739376]
Liver registration by overlaying preoperative 3D models onto intraoperative 2D frames can assist surgeons in perceiving the spatial anatomy of the liver clearly for a higher surgical success rate.<n>Existing registration methods rely heavily on anatomical landmark-based, which encounter two major limitations.<n>We propose a landmark-free preoperative-to-intraoperative registration framework utilizing effective self-supervised learning.
arXiv Detail & Related papers (2025-04-21T14:55:57Z) - Intraoperative Glioma Segmentation with YOLO + SAM for Improved Accuracy in Tumor Resection [1.9461727843485295]
Gliomas present significant surgical challenges due to similarity to healthy tissue.
MRI images are often ineffective during surgery due to factors such as brain shift.
This paper presents a deep learning pipeline combining You Only Look Once Version 8 (Yv8) and Segment Anything Model Vision Transformer-base.
arXiv Detail & Related papers (2024-08-27T07:58:08Z) - Epicardium Prompt-guided Real-time Cardiac Ultrasound Frame-to-volume Registration [50.602074919305636]
This paper introduces a lightweight end-to-end Cardiac Ultrasound frame-to-volume Registration network, termed CU-Reg.<n>We use epicardium prompt-guided anatomical clues to reinforce the interaction of 2D sparse and 3D dense features, followed by a voxel-wise local-global aggregation of enhanced features.
arXiv Detail & Related papers (2024-06-20T17:47:30Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - Learning-Based Keypoint Registration for Fetoscopic Mosaicking [65.02392513942533]
In Twin-to-Twin Transfusion Syndrome (TTTS), abnormal vascular anastomoses in the monochorionic placenta can produce uneven blood flow between the two fetuses.
We propose a learning-based framework for in-vivo fetoscopy frame registration for field-of-view expansion.
arXiv Detail & Related papers (2022-07-26T21:21:12Z) - Weakly-supervised Biomechanically-constrained CT/MRI Registration of the
Spine [72.85011943179894]
We propose a weakly-supervised deep learning framework that preserves the rigidity and the volume of each vertebra while maximizing the accuracy of the registration.
We specifically design these losses to depend only on the CT label maps since automatic vertebra segmentation in CT gives more accurate results contrary to MRI.
Our results show that adding the anatomy-aware losses increases the plausibility of the inferred transformation while keeping the accuracy untouched.
arXiv Detail & Related papers (2022-05-16T10:59:55Z) - A Long Short-term Memory Based Recurrent Neural Network for
Interventional MRI Reconstruction [50.1787181309337]
We propose a convolutional long short-term memory (Conv-LSTM) based recurrent neural network (RNN), or ConvLR, to reconstruct interventional images with golden-angle radial sampling.
The proposed algorithm has the potential to achieve real-time i-MRI for DBS and can be used for general purpose MR-guided intervention.
arXiv Detail & Related papers (2022-03-28T14:03:45Z) - Unsupervised-learning-based method for chest MRI-CT transformation using
structure constrained unsupervised generative attention networks [0.0]
The integrated positron emission tomography/magnetic resonance imaging (PET/MRI) scanner facilitates the simultaneous acquisition of metabolic information via PET and morphological information using MRI.
PET/MRI requires the generation of attenuation-correction maps from MRI owing to no direct relationship between the gamma-ray attenuation information and MRIs.
This paper presents a means to minimise the anatomical structural changes without human annotation by adding structural constraints using a modality-independent neighbourhood descriptor (MIND) to a generative adversarial network (GAN) that can transform unpaired images.
arXiv Detail & Related papers (2021-06-16T05:22:27Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.