Projection-Domain Sensitivity Analysis of Vertebral DRRs Under Intrinsic Calibration Perturbation
- URL: http://arxiv.org/abs/2607.10551v1
- Date: Sun, 12 Jul 2026 03:34:29 GMT
- Title: Projection-Domain Sensitivity Analysis of Vertebral DRRs Under Intrinsic Calibration Perturbation
- Abstract summary: This study presents a synthetic framework for evaluating how intrinsic calibration perturbations affect vertebral fluoroscopic projections and downstream registration performance.<n>Results show that even small intrinsic calibration perturbations produce measurable changes in vertebral projection geometry, contour morphology, landmark localization, and DRR appearance.<n>This approach may improve the reliability of DRR generation and fluoroscopy-guided vertebral registration in image-guided spinal applications.
- Score: 4.1669009168926365
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Accurate geometric calibration is essential for fluoroscopy-guided spinal imaging, digitally reconstructed radiograph (DRR) generation, and 2D--3D vertebral registration. Although calibration quality is typically evaluated using reconstruction-based metrics such as reprojection error, its influence on projection-domain consistency remains poorly understood. This study presents a synthetic framework for evaluating how intrinsic calibration perturbations affect vertebral fluoroscopic projections and downstream registration performance. CT-derived vertebral models and controlled cone-beam imaging geometry were used to generate DRRs with both ground-truth and perturbed intrinsic calibration parameters while maintaining identical anatomy and acquisition pose. Projection-domain changes were quantified using anatomical landmark displacement, contour distance, silhouette overlap, image similarity, and landmark-based 2D--3D registration accuracy in anterior--posterior (AP) and lateral (LAT) views. Results show that even small intrinsic calibration perturbations produce measurable changes in vertebral projection geometry, contour morphology, landmark localization, and DRR appearance. Sensitivity is strongly view dependent, with LAT projections exhibiting substantially greater deformation and anatomical displacement than AP projections. These projection inconsistencies also degrade downstream 2D--3D registration, particularly rotational alignment accuracy. The findings demonstrate that projection-domain consistency complements conventional reconstruction-based calibration metrics and provides a practical framework for assessing calibration robustness. This approach may improve the reliability of DRR generation and fluoroscopy-guided vertebral registration in image-guided spinal applications.
Related papers
- Accurate Reconstruction of Gas Turbine Blade Geometry Using 3D/2D Rigid Registration and CT View Optimization [0.0]
Non-destructive X-ray and computed tomography (CT) testing are essential for ensuring the dimensional accuracy of manufactured components.<n>This study presents a multipart 3D-2D rigid registration approach for aligning CAD models with X-ray projections.
arXiv Detail & Related papers (2026-09-01T15:06:11Z) - Revisiting Pose Sensitivity in Splat-based Computed Tomography under Sparse-view Reconstruction [12.315488379543773]
Recent splat-based tomography has demonstrated both high reconstruction quality and fast convergence in cone-beam sparse-view CT.<n>We observe distinctive streak and strip artifacts that are far more pronounced than in conventional reconstruction methods.<n>We derive a stable gradient-based framework that jointly refines geometric parameters during reconstruction.
arXiv Detail & Related papers (2026-08-05T12:20:53Z) - DOC-GS: Dual-Domain Observation and Calibration for Reliable Sparse-View Gaussian Splatting [80.43237927269575]
In this paper, we revisit sparse-view 3DGS reconstruction from a new perspective.<n>We identify the core challenge as the unobservability of Gaussian primitive reliability.<n>Motivated by this observation, we propose a unified Dual-domain Observation and geometrics in rendered images framework.
arXiv Detail & Related papers (2026-04-08T07:01:24Z) - Preoperative-to-intraoperative Liver Registration for Laparoscopic Surgery via Latent-Grounded Correspondence Constraints [51.7011449975586]
Land-Reg is a deformable registration framework that learns latent-grounded 2D-3D landmark correspondences.<n>For rigid registration, Land-Reg embraces a Cross-modal Latent Alignment module.<n>An Uncertainty-enhanced Overlap Landmark Detector with similarity matching is proposed to robustly estimate explicit 2D-3D landmark correspondences.
arXiv Detail & Related papers (2026-03-02T10:44:03Z) - Geometry OR Tracker: Universal Geometric Operating Room Tracking [61.399734016038614]
In operating rooms (OR), world-scale multi-view 3D tracking supports downstream applications such as surgeon behavior recognition.<n>Camera calibration and RGB-D registration are always unreliable, leading to cross-view geometric inconsistency.<n>We introduce Geometry OR Tracker, a two-stage pipeline that rectifies imprecise calibration into a scaleconsistent and geometrically consistent camera setup.
arXiv Detail & Related papers (2026-02-28T09:21:21Z) - Silhouette-to-Contour Registration: Aligning Intraoral Scan Models with Cephalometric Radiographs [10.70146635420186]
We propose DentalSCR, a pose-stable, contour-guided framework for accurate and interpretable silhouette-to-contour registration.<n>We evaluate DentalSCR on 34 expert-annotated clinical cases.
arXiv Detail & Related papers (2025-11-18T10:50:04Z) - Registration is a Powerful Rotation-Invariance Learner for 3D Anomaly Detection [64.0168648353038]
3D anomaly detection in point-cloud data is critical for industrial quality control, aiming to identify structural defects with high reliability.<n>Current memory bank-based methods often suffer from inconsistent feature transformations and limited discriminative capacity.<n>We propose a registration-induced, rotation-invariant feature extraction framework that integrates the objectives of point-cloud registration and memory-based anomaly detection.
arXiv Detail & Related papers (2025-10-19T14:56:38Z) - Marker-Based Extrinsic Calibration Method for Accurate Multi-Camera 3D Reconstruction [0.23749905164931198]
In this paper, we introduce an iterative extrinsic calibration method that leverages the geometric constraints provided by a three-dimensional marker.<n>We validate our method comprehensively in both controlled environments and practical real-world settings within the Tech4Diet project.<n> Experimental results demonstrate substantial reductions in alignment errors, facilitating accurate and reliable 3D reconstructions.
arXiv Detail & Related papers (2025-05-05T10:21:41Z) - 2D/3D Registration of Acetabular Hip Implants Under Perspective Projection and Fully Differentiable Ellipse Fitting [1.8352113484137624]
This paper presents a novel method for estimating the orientation and position of acetabular hip implants in total hip using full anterior-posterior hip fluoroscopy images.<n> Experimental results from both numerically simulated and digitally reconstructed radiograph environments demonstrate high accuracy with minimal computational demands.
arXiv Detail & Related papers (2025-03-10T18:34:41Z) - CoCPF: Coordinate-based Continuous Projection Field for Ill-Posed Inverse Problem in Imaging [78.734927709231]
Sparse-view computed tomography (SVCT) reconstruction aims to acquire CT images based on sparsely-sampled measurements.
Due to ill-posedness, implicit neural representation (INR) techniques may leave considerable holes'' (i.e., unmodeled spaces) in their fields, leading to sub-optimal results.
We propose the Coordinate-based Continuous Projection Field (CoCPF), which aims to build hole-free representation fields for SVCT reconstruction.
arXiv Detail & Related papers (2024-06-21T08:38:30Z) - Tattoo tomography: Freehand 3D photoacoustic image reconstruction with
an optical pattern [49.240017254888336]
Photoacoustic tomography (PAT) is a novel imaging technique that can resolve both morphological and functional tissue properties.
A current drawback is the limited field-of-view provided by the conventionally applied 2D probes.
We present a novel approach to 3D reconstruction of PAT data that does not require an external tracking system.
arXiv Detail & Related papers (2020-11-10T09:27:56Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.