Diffusion MRI preprocessing affects ADC estimation and automatic PI-RADS v2.1 classification in bi-parametric prostate MRI
- URL: http://arxiv.org/abs/2607.11385v1
- Date: Mon, 13 Jul 2026 10:45:13 GMT
- Title: Diffusion MRI preprocessing affects ADC estimation and automatic PI-RADS v2.1 classification in bi-parametric prostate MRI
- Abstract summary: Diffusion-weighted imaging (DWI) is acquired as part of bi-parametric prostate MRI.<n>While DWI preprocessing is standard in brain imaging, its adoption in prostate imaging remains limited and lacks standardized pipelines.<n>This study investigated the effect of different DWI preprocessing strategies on apparent diffusion coefficient estimation and automatic Prostate Imaging Reporting and Data System (PI-RADS) classification.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Diffusion-weighted imaging (DWI) is acquired as part of bi-parametric prostate MRI, but suffers from artifacts that degrade downstream quantitative and diagnostic performance. While DWI preprocessing is standard in brain imaging, its adoption in prostate imaging remains limited and lacks standardized pipelines. This study investigated the effect of different DWI preprocessing strategies on apparent diffusion coefficient (ADC) estimation and automatic Prostate Imaging Reporting and Data System (PI-RADS) classification. 268 cases were derived from the fastMRI prostate cohort by sequentially applying denoising, Gibbs-ringing correction, and diffeomorphic registration for susceptibility distortion correction. ADC maps were compared using linear least squares (LLS) and iteratively-weighted LLS (IWLLS). A 3-class DenseNet classifier was trained to predict PI-RADS scores from multi-channel MRI inputs. ADC analysis revealed statistically significant differences across preprocessing pipelines, with LLS and IWLLS producing numerically equivalent maps. Linear relationships between ADC values were preserved across most datasets (PCC ~0.99), while distortion correction realigned DWI to T2w anatomy and altered ADC values accordingly (PCC ~0.90). Classification showed the best AUROC and sensitivity for high-risk PI-RADS classes in the fully processed dataset. False-negative analysis revealed this dataset produced the least overconfident incorrect predictions on high-risk classes, which is a desirable property for clinical triage. DWI preprocessing, particularly distortion correction, enhances both ADC map quality and the predictive power of deep learning models for PI-RADS classification, supporting the need for optimized preprocessing pipelines in prostate MRI.
Related papers
- Bridging Single Distortion Artifacts and Multifactorial Clinical Quality: Few-shot Biparametric MRI Quality Assessment via Distortion-trained Prototypical Networks [37.46263264161563]
We propose a few-shot prototypical network for automated image quality assessment (IQA)<n>Our framework utilizes a dual-branch 3D ResNet to fuse T2-weighted and DWI features, providing anatomical context to distinguish true morphology from distortion.<n>We demonstrate that a model meta-trained solely on comparatively objective, readily obtainable distortion labels can effectively adapt to predicting complex, multifactorial clinical quality scores.
arXiv Detail & Related papers (2026-06-17T09:50:45Z) - Maximizing T2-Only Prostate Cancer Localization from Expected Diffusion Weighted Imaging [68.57480103120561]
Multiparametric MRI is increasingly recommended as a first-line noninvasive approach to detect and localize prostate cancer.<n>Early machine learning attempts using only T2w images have shown promising diagnostic performance in segmenting radiologist-annotated lesions.<n>This work investigates an arguably more challenging application using only T2w at inference, but to localize individual cancers based on independent histopathology labels.
arXiv Detail & Related papers (2026-04-01T14:50:18Z) - ODySSeI: An Open-Source End-to-End Framework for Automated Detection, Segmentation, and Severity Estimation of Lesions in Invasive Coronary Angiography Images [23.05175906366438]
Invasive Coronary Angiography (ICA) is the clinical gold standard for the assessment of coronary artery disease.<n>In this work, we introduce ODySSeI: an Open-source framework for automated Detection, lesions, and Severity estimation in ICA images.<n> ODySSeI integrates deep learning-based lesion detection and lesion segmentation models trained using a novel Pyramidal Augmentation Scheme (PAS)<n>Our LSE technique achieves high accuracy, with predicted MLD values differing by only $pm$ 2-3 pixels from the corresponding ground truths.
arXiv Detail & Related papers (2026-03-20T15:07:15Z) - Dual-Encoder Transformer-Based Multimodal Learning for Ischemic Stroke Lesion Segmentation Using Diffusion MRI [5.332404648315838]
We study ischemic stroke lesion segmentation using multimodal diffusion MRI from the ISLES 2022 dataset.<n>Several state-of-the-art convolutional and transformer-based architectures, including U-Net variants, Swin-UNet, and TransUNet, are benchmarked.<n>Results show that transformer-based models outperform convolutional baselines, and the proposed dual-encoder TransUNet achieves the best performance, reaching a Dice score of 85.4% on the test set.
arXiv Detail & Related papers (2025-12-23T15:24:31Z) - Mitigating Multi-Sequence 3D Prostate MRI Data Scarcity through Domain Adaptation using Locally-Trained Latent Diffusion Models for Prostate Cancer Detection [1.6508709227918446]
Latent diffusion models (LDMs) could mitigate data scarcity challenges affecting machine learning development for medical image interpretation.<n>We propose CCELLA++ to address these limitations and improve clinical utility.
arXiv Detail & Related papers (2025-07-08T20:38:10Z) - Enhancing Angular Resolution via Directionality Encoding and Geometric Constraints in Brain Diffusion Tensor Imaging [70.66500060987312]
Diffusion-weighted imaging (DWI) is a type of Magnetic Resonance Imaging (MRI) technique sensitised to the diffusivity of water molecules.
This work proposes DirGeo-DTI, a deep learning-based method to estimate reliable DTI metrics even from a set of DWIs acquired with the minimum theoretical number (6) of gradient directions.
arXiv Detail & Related papers (2024-09-11T11:12:26Z) - UDCR: Unsupervised Aortic DSA/CTA Rigid Registration Using Deep
Reinforcement Learning and Overlap Degree Calculation [12.201553863670155]
We propose an unsupervised method, UDCR, for aortic DSA/CTA rigid registration based on deep reinforcement learning.
We manually annotated 61 pairs of aortic DSA/CTA for algorithm evaluation. The results indicate that the proposed UDCR achieved a Mean Absolute Error (MAE) of 2.85 mm in translation and 4.35deg in rotation.
arXiv Detail & Related papers (2024-03-09T01:18:32Z) - Domain Transfer Through Image-to-Image Translation for Uncertainty-Aware Prostate Cancer Classification [42.75911994044675]
We present a novel approach for unpaired image-to-image translation of prostate MRIs and an uncertainty-aware training approach for classifying clinically significant PCa.
Our approach involves a novel pipeline for translating unpaired 3.0T multi-parametric prostate MRIs to 1.5T, thereby augmenting the available training data.
Our experiments demonstrate that the proposed method significantly improves the Area Under ROC Curve (AUC) by over 20% compared to the previous work.
arXiv Detail & Related papers (2023-07-02T05:26:54Z) - Negligible effect of brain MRI data preprocessing for tumor segmentation [36.89606202543839]
We conduct experiments on three publicly available datasets and evaluate the effect of different preprocessing steps in deep neural networks.
Our results demonstrate that most popular standardization steps add no value to the network performance.
We suggest that image intensity normalization approaches do not contribute to model accuracy because of the reduction of signal variance with image standardization.
arXiv Detail & Related papers (2022-04-11T17:29:36Z) - Improving Classification Model Performance on Chest X-Rays through Lung
Segmentation [63.45024974079371]
We propose a deep learning approach to enhance abnormal chest x-ray (CXR) identification performance through segmentations.
Our approach is designed in a cascaded manner and incorporates two modules: a deep neural network with criss-cross attention modules (XLSor) for localizing lung region in CXR images and a CXR classification model with a backbone of a self-supervised momentum contrast (MoCo) model pre-trained on large-scale CXR data sets.
arXiv Detail & Related papers (2022-02-22T15:24:06Z) - Multiple Time Series Fusion Based on LSTM An Application to CAP A Phase
Classification Using EEG [56.155331323304]
Deep learning based electroencephalogram channels' feature level fusion is carried out in this work.
Channel selection, fusion, and classification procedures were optimized by two optimization algorithms.
arXiv Detail & Related papers (2021-12-18T14:17:49Z) - Generalizing electrocardiogram delineation: training convolutional
neural networks with synthetic data augmentation [63.51064808536065]
Existing databases for ECG delineation are small, being insufficient in size and in the array of pathological conditions they represent.
This article delves has two main contributions. First, a pseudo-synthetic data generation algorithm was developed, based in probabilistically composing ECG traces given "pools" of fundamental segments, as cropped from the original databases, and a set of rules for their arrangement into coherent synthetic traces.
Second, two novel segmentation-based loss functions have been developed, which attempt at enforcing the prediction of an exact number of independent structures and at producing closer segmentation boundaries by focusing on a reduced number of samples.
arXiv Detail & Related papers (2021-11-25T10:11:41Z) - Controlling False Positive/Negative Rates for Deep-Learning-Based
Prostate Cancer Detection on Multiparametric MR images [58.85481248101611]
We propose a novel PCa detection network that incorporates a lesion-level cost-sensitive loss and an additional slice-level loss based on a lesion-to-slice mapping function.
Our experiments based on 290 clinical patients concludes that 1) The lesion-level FNR was effectively reduced from 0.19 to 0.10 and the lesion-level FPR was reduced from 1.03 to 0.66 by changing the lesion-level cost.
arXiv Detail & Related papers (2021-06-04T09:51:27Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.