- Abstract summary: Manual craniotomy is a high-risk, skill-dependent procedure associated with surgeon fatigue and potential dural injury.<n>We propose a human-inspired closed-loop robotic craniotomy framework that intelligently integrates preoperative planning with intraoperative execution.<n>Experiments on bovine ribs show a breakthrough prediction accuracy of 97%, a detection latency of 0.048 +/- 0.097 s, and a maximum overshoot of 0.29 mm.
- Score: 11.44210370034241
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Manual craniotomy is a high-risk, skill-dependent procedure associated with surgeon fatigue and potential dural injury. While robotic approaches have improved safety, existing open-loop systems rely solely on preoperative images and cannot compensate for intraoperative registration errors or tissue deformation. To address this, we propose a human-inspired closed-loop robotic craniotomy framework that intelligently integrates preoperative planning with intraoperative execution. An adaptive dual-contour fusion algorithm is employed to generate trajectories that conform to complex cranial geometries while maintaining a consistent tool-bone relative pose. For intraoperative perception, a multimodal two-stage cross-modal attention block (CMA)-temporal convolutional network (TCN)-Transformer network combined with an adaptive Bayesian filter fuses force and acoustic signals to achieve robust breakthrough detection under varying bone conditions. Upon detection, an in-situ projection-based trajectory adjustment strategy dynamically compensates for depth deviations, enabling safe residual bone isolation. Experiments on bovine ribs show a breakthrough prediction accuracy of 97%, a detection latency of 0.048 +/- 0.097 s, and a maximum overshoot of 0.29 mm. All four ex vivo cranial experiments were successfully completed without dural injury. These results demonstrate that the proposed cybernetic framework enables safe and autonomous craniotomy with highly effective closed-loop control.
Related papers
- Brain-WM: Brain Glioblastoma World Model [56.45393372490125]
We present Brain-WM, a pioneering GBM world model that unifies next-step treatment prediction and future MRI generation.<n>Brain-WM encodes latent dynamics into a shared latent space for joint autoregressive treatment prediction and flow-based future MRI generation.<n>Ultimately, Brain-WM offers a robust clinical sandbox for optimizing patient healthcare.
arXiv Detail & Related papers (2026-03-08T09:54:08Z) - Modeling and Control of a Pneumatic Soft Robotic Catheter Using Neural Koopman Operators [3.2642164905437503]
We propose a neural network-enhanced Koopman operator framework for advancing soft robotic catheter systems.<n>Motivated by the need to minimize radiation exposure during X-ray fluoroscopy in cardiac ablation, we investigate open-loop control strategies.<n>Our approach achieves average errors of 2.1 +- 0.4 mm in position and 4.9 +- 0.6 degrees in orientation.
arXiv Detail & Related papers (2026-03-04T14:36:22Z) - DRBD-Mamba for Robust and Efficient Brain Tumor Segmentation with Analytical Insights [54.87947751720332]
Accurate brain tumor segmentation is significant for clinical diagnosis and treatment.<n>Mamba-based State Space Models have demonstrated promising performance.<n>We propose a dual-resolution bi-directional Mamba that captures multi-scale long-range dependencies with minimal computational overhead.
arXiv Detail & Related papers (2025-10-16T07:31:21Z) - Robotic Ultrasound-Guided Femoral Artery Reconstruction of Anatomically-Representative Phantoms [2.1113382954657594]
Femoral artery access is essential for numerous clinical procedures, including diagnostic angiography, therapeutic catheterization, and emergency interventions.<n>Despite its critical role, successful vascular access remains challenging due to anatomical variability, overlying adipose tissue, and the need for precise ultrasound guidance.<n>We present a method for autonomous robotic US scanning of bifurcated femoral arteries, and validate it on five vascular phantoms created from real patient computed tomography (CT) data.
arXiv Detail & Related papers (2025-03-09T22:20:25Z) - Autonomous Vision-Guided Resection of Central Airway Obstruction [0.0]
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance.<n>We present a vision-guided, autonomous approach for palliative resection of tracheal tumors.
arXiv Detail & Related papers (2025-02-25T19:11:11Z) - Automatic registration with continuous pose updates for marker-less
surgical navigation in spine surgery [52.63271687382495]
We present an approach that automatically solves the registration problem for lumbar spinal fusion surgery in a radiation-free manner.
A deep neural network was trained to segment the lumbar spine and simultaneously predict its orientation, yielding an initial pose for preoperative models.
An intuitive surgical guidance is provided thanks to the integration into an augmented reality based navigation system.
arXiv Detail & Related papers (2023-08-05T16:26:41Z) - Safe Deep RL for Intraoperative Planning of Pedicle Screw Placement [61.28459114068828]
We propose an intraoperative planning approach for robotic spine surgery that leverages real-time observation for drill path planning based on Safe Deep Reinforcement Learning (DRL)
Our approach was capable of achieving 90% bone penetration with respect to the gold standard (GS) drill planning.
arXiv Detail & Related papers (2023-05-09T11:42:53Z) - Automatic Detection and Segmentation of Postoperative Cerebellar Damage
Based on Normalization [1.1470070927586016]
A reliable localization and measure of cerebellar damage is fundamental to study the relationship between the damaged cerebellar regions and postoperative neurological outcomes.
Existing cerebellum normalization methods are not reliable on postoperative scans, therefore current approaches to measure surgical damage rely on manual labelling.
We develop a robust algorithm to automatically detect and measure cerebellum damage due to surgery using postoperative 3D T1 magnetic resonance imaging.
arXiv Detail & Related papers (2022-03-03T22:26:59Z) - Multiple Time Series Fusion Based on LSTM An Application to CAP A Phase
Classification Using EEG [56.155331323304]
Deep learning based electroencephalogram channels' feature level fusion is carried out in this work.
Channel selection, fusion, and classification procedures were optimized by two optimization algorithms.
arXiv Detail & Related papers (2021-12-18T14:17:49Z) - Real-time landmark detection for precise endoscopic submucosal
dissection via shape-aware relation network [51.44506007844284]
We propose a shape-aware relation network for accurate and real-time landmark detection in endoscopic submucosal dissection surgery.
We first devise an algorithm to automatically generate relation keypoint heatmaps, which intuitively represent the prior knowledge of spatial relations among landmarks.
We then develop two complementary regularization schemes to progressively incorporate the prior knowledge into the training process.
arXiv Detail & Related papers (2021-11-08T07:57:30Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.