Feasibility of Embedded Photoplethysmography Sensing in Short-Duration Tactile Interactions With Pocket-Sized Robots Using IMU- and Confidence-Based Filtering
- URL: http://arxiv.org/abs/2608.04242v1
- Date: Tue, 04 Aug 2026 21:51:12 GMT
- Title: Feasibility of Embedded Photoplethysmography Sensing in Short-Duration Tactile Interactions With Pocket-Sized Robots Using IMU- and Confidence-Based Filtering
- Abstract summary: This paper investigates the integration of an embedded photoplethys (Pocket) sensor directly into a pocket-sized companion robot, Affectathy.<n>We address the significant challenge of motion artifacts inherent in handheld usage by implementing a two-stage filtering pipeline.<n>Our results demonstrate that the filtering strategy significantly reduced the Mean Absolute Percentage Error and achieved statistical equivalence to the ground truth measurements.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Ubiquitous companion robots offer a promising avenue for immediate anxiety relief in children, yet their effectiveness relies on the ability to monitor physiological states continuously and unobtrusively. Current solutions often depend on external wearables, which impose usability barriers and limit the robot's autonomy. This paper investigates the integration of an embedded photoplethysmography (PPG) sensor directly into a pocket-sized companion robot, AffectaPocket, to enable self-contained heart rate monitoring during tactile interaction. We address the significant challenge of motion artifacts inherent in handheld usage by implementing a two-stage filtering pipeline that utilizes an onboard Inertial Measurement Unit (IMU) to reject high-variance segments and a confidence-based smoothing algorithm for recovery periods. We evaluated the system against a commonly used wrist worn sensor in a Within-Subjects Study with 26 participants. Our results demonstrate that the filtering strategy significantly reduced the Mean Absolute Percentage Error and achieved statistical equivalence to the ground truth measurements (p<0.05). Analysis of short-duration interactions shows that the sensor requires stability over longer periods to converge.
Related papers
- Freezing of Gait Prediction Under Spatial Occlusion: An IMU-Supervised Cross-Modal Distillation Approach [0.0]
Parkinson's disease is a progressive neurodegenerative disorder characterised by gradual deterioration of movement control.<n> automated freezing-of-gait (FOG) detection supports the objective assessment of gait-related motor impairment.<n>Two common approaches are used for FOG prediction: (i) analysing video recordings of the patient's movements and (ii) analysing data collected using inertial measurement unit (IMU) wearable sensors attached to the patient's lower limbs.<n>Video-based approaches may suffer detection errors during continuous turning-in-place tasks because the lower limbs undergo substantial geometric self-occlusion, degrading pose-estimation accuracy.
arXiv Detail & Related papers (2026-09-09T07:29:13Z) - Seeing Through Occlusion: Deterministic Arm Kinematic Correction for Robot Teleoperation [6.979012378888037]
This paper presents an Arm Kinematic Correction (AKC) method that improves depth estimation by enforcing geometric constraints based on constant arm lengths.<n> Experimental validation against a Vicon reference system demonstrates reliable performance for both static and dynamic joint motions.<n>The results show that AKC enhances robustness and preserves anatomical consistency under long-duration, severe self-occlusion, even when paired with less reliable temporal filters.
arXiv Detail & Related papers (2026-06-17T16:20:10Z) - Design and Validation of a Lightweight 1D CNN for Affective Touch Classification in Soft Plush Companions [59.49967357689445]
Soft, sensorized companions offer a physically safe and emotionally intuitive interface for socially assistive technologies.<n>This study presents a complete open-source dilated real-based framework for the development and validation of deep learning models for affective touch recognition in soft interactive companions.
arXiv Detail & Related papers (2026-04-16T10:20:05Z) - Learning-based Force Sensing and Impedance Matching for Safe Haptic Feedback in Robot-assisted Laparoscopic Surgery [0.0]
Impedance Matching Approach (NIMA) incorporates nonlinear dynamics to accurately model and render complex tool-tissue interactions in real-time.<n>NIMA achieves a mean absolute error of 0.01 (std 0.02 N), representing a 95% reduction compared to previous approaches.<n>NIMA significantly improves force fidelity, responsiveness, and precision across various surgical conditions.
arXiv Detail & Related papers (2026-01-20T19:57:50Z) - The power of dynamic causality in observer-based design for soft sensor applications [0.7965327033045845]
This paper introduces a novel framework for optimizing observer-based soft sensors through dynamic causality analysis.<n>Traditional approaches to sensor selection often rely on linearized observability indices or statistical correlations that fail to capture the temporal evolution of complex systems.
arXiv Detail & Related papers (2025-09-14T16:27:58Z) - Sensor Response-Time Reduction using Long-Short Term Memory Network Forecasting [0.0]
Response time of a biosensor is a crucial metric in safety-critical applications such as medical diagnostics.
We show that ensembles of long short-term memory (LSTM) networks can accurately predict equilibrium biosensor response.
arXiv Detail & Related papers (2024-04-26T04:21:14Z) - Analyzing Participants' Engagement during Online Meetings Using Unsupervised Remote Photoplethysmography with Behavioral Features [50.82725748981231]
Engagement measurement finds application in healthcare, education, services.
Use of physiological and behavioral features is viable, but impracticality of traditional physiological measurement arises due to the need for contact sensors.
We demonstrate the feasibility of the unsupervised photoplethysmography (rmography) as an alternative for contact sensors.
arXiv Detail & Related papers (2024-04-05T20:39:16Z) - Efficient Real-time Smoke Filtration with 3D LiDAR for Search and Rescue
with Autonomous Heterogeneous Robotic Systems [56.838297900091426]
Smoke and dust affect the performance of any mobile robotic platform due to their reliance on onboard perception systems.
This paper proposes a novel modular computation filtration pipeline based on intensity and spatial information.
arXiv Detail & Related papers (2023-08-14T16:48:57Z) - Online Body Schema Adaptation through Cost-Sensitive Active Learning [63.84207660737483]
The work was implemented in a simulation environment, using the 7DoF arm of the iCub robot simulator.
A cost-sensitive active learning approach is used to select optimal joint configurations.
The results show cost-sensitive active learning has similar accuracy to the standard active learning approach, while reducing in about half the executed movement.
arXiv Detail & Related papers (2021-01-26T16:01:02Z) - Video-based Remote Physiological Measurement via Cross-verified Feature
Disentangling [121.50704279659253]
We propose a cross-verified feature disentangling strategy to disentangle the physiological features with non-physiological representations.
We then use the distilled physiological features for robust multi-task physiological measurements.
The disentangled features are finally used for the joint prediction of multiple physiological signals like average HR values and r signals.
arXiv Detail & Related papers (2020-07-16T09:39:17Z) - MIMC-VINS: A Versatile and Resilient Multi-IMU Multi-Camera
Visual-Inertial Navigation System [44.76768683036822]
We propose a real-time consistent multi-IMU multi-camera (CMU)-VINS estimator for visual-inertial navigation systems.
Within an efficient multi-state constraint filter, the proposed MIMC-VINS algorithm optimally fuses asynchronous measurements from all sensors.
The proposed MIMC-VINS is validated in both Monte-Carlo simulations and real-world experiments.
arXiv Detail & Related papers (2020-06-28T20:16:08Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.