Multimodal Shared Latent Representation of Narration, Microscope and iOCT Images for Phase Recognition in Vitreoretinal Surgery
- URL: http://arxiv.org/abs/2608.31065v1
- Date: Mon, 31 Aug 2026 16:41:07 GMT
- Title: Multimodal Shared Latent Representation of Narration, Microscope and iOCT Images for Phase Recognition in Vitreoretinal Surgery
- Abstract summary: Surgical phase recognition is key to context-aware computer-assisted feedback in vitreoretinal procedures.<n>We introduce a framework that uses microscope views as a shared anchor to bridge surgical narrations and intraoperative OCT.<n>This is the first work to unify microscope view, i OCT B-scans, and surgical narrations in a shared latent space for surgical phase recognition.
- Score: 37.94518682851121
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Surgical phase recognition is key to context-aware computer-assisted feedback in vitreoretinal procedures, yet the scarcity of synchronized multimodal intraoperative data, particularly microscope views and intraoperative OCT, limits approaches that aim to replicate the multimodal integration surgeons perform naturally. Surgical narration, by contrast, is abundantly available online and offers rich semantic supervision. Prior work has mainly explored pairwise contrastive learning (e.g., intraoperative OCT-microscope or microscope-narration), leaving the joint modeling of all three modalities largely unexplored. We introduce a framework that uses microscope views as a shared anchor to bridge surgical narrations and intraoperative OCT (iOCT) without requiring a fully synchronized tri-modal dataset, leveraging real microscope-narration videos and a synthetic dataset of synchronized microscope video and tool-aligned iOCT pairs. Contrastive alignment transfers structural priors from the synthetic domain to real videos lacking iOCT, and a dual-head MS-TCN++ integrates the resulting embeddings for joint macro- and micro-phase prediction. Evaluated on real vitreoretinal surgeries, our framework improves macro-phase recognition over a zero-shot baseline (mean F1 0.38 to 0.53) and provides an exploratory route to estimating fine-grained instrument-tissue measurements that are not directly observable in real microscope video alone; these micro-phase estimates are validated quantitatively on synthetic data and shown only qualitatively on real surgery. To our knowledge, this is the first work to unify microscope view, iOCT B-scans, and surgical narrations in a shared latent space for surgical phase recognition.
Related papers
- MMBU: A Massive Multi-modal Biomedical Understanding Benchmark to Probe the Perception Capabilities of Vision-Language Models [83.50100003741628]
Vision and language models (VLMs) hold immense promise to transform biomedical imaging.<n>We introduce the Massive Multimodal Biomedical Understanding (MMBU) benchmark.<n>It is the largest vision and language benchmark to date, covering 35 submodalities with rich structured metadata.
arXiv Detail & Related papers (2026-06-04T20:24:47Z) - Monocular Marker-free Patient-to-Image Intraoperative Registration for Cochlear Implant Surgery [4.250558597144547]
Our framework seamlessly integrates with monocular surgical microscopes, making it highly practical for clinical use without additional hardware dependencies and requirements.<n>Our results suggest that our approach achieves clinically relevant accuracy in predicting 6D camera poses for registering 3D preoperative CT scans to 2D surgical scenes with an angular error within 10 degrees in most cases.
arXiv Detail & Related papers (2025-05-23T21:15:00Z) - Post-mastoidectomy Surface Multi-View Synthesis from a Single Microscopy Image [4.777201894011511]
We introduce a novel pipeline that is capable of generating synthetic multi-view videos from a single CI microscope image.<n>We use a patient's pre-operative CT scan to predict the post-mastoidectomy surface using a method designed for this purpose.
arXiv Detail & Related papers (2024-08-31T16:45:24Z) - The Quest for Early Detection of Retinal Disease: 3D CycleGAN-based Translation of Optical Coherence Tomography into Confocal Microscopy [11.321411104729002]
We propose a novel framework based on unsupervised 3D CycleGAN for translating unpaired in vivo OCT to ex vivo confocal microscopy images.
This marks the first attempt to exploit the inherent 3D information of OCT and translate it into the rich, detailed color domain of confocal microscopy.
arXiv Detail & Related papers (2024-08-07T21:13:49Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - Monocular Microscope to CT Registration using Pose Estimation of the
Incus for Augmented Reality Cochlear Implant Surgery [3.8909273404657556]
We develop a method that permits direct 2D-to-3D registration of the view microscope video to the pre-operative Computed Tomography (CT) scan without the need for external tracking equipment.
Our results demonstrate the accuracy with an average rotation error of less than 25 degrees and a translation error of less than 2 mm, 3 mm, and 0.55% for the x, y, and z axes, respectively.
arXiv Detail & Related papers (2024-03-12T00:26:08Z) - Style transfer between Microscopy and Magnetic Resonance Imaging via Generative Adversarial Network in small sample size settings [45.62331048595689]
Cross-modal augmentation of Magnetic Resonance Imaging (MRI) and microscopic imaging based on the same tissue samples is promising.<n>We tested a method for generating microscopic histological images from MRI scans of the human corpus callosum using conditional generative adversarial network (cGAN) architecture.
arXiv Detail & Related papers (2023-10-16T13:58:53Z) - Phase-Specific Augmented Reality Guidance for Microscopic Cataract
Surgery Using Long-Short Spatiotemporal Aggregation Transformer [14.568834378003707]
Phaemulsification cataract surgery (PCS) is a routine procedure using a surgical microscope.
PCS guidance systems extract valuable information from surgical microscopic videos to enhance proficiency.
Existing PCS guidance systems suffer from non-phasespecific guidance, leading to redundant visual information.
We propose a novel phase-specific augmented reality (AR) guidance system, which offers tailored AR information corresponding to the recognized surgical phase.
arXiv Detail & Related papers (2023-09-11T02:56:56Z) - CholecTriplet2021: A benchmark challenge for surgical action triplet
recognition [66.51610049869393]
This paper presents CholecTriplet 2021: an endoscopic vision challenge organized at MICCAI 2021 for the recognition of surgical action triplets in laparoscopic videos.
We present the challenge setup and assessment of the state-of-the-art deep learning methods proposed by the participants during the challenge.
A total of 4 baseline methods and 19 new deep learning algorithms are presented to recognize surgical action triplets directly from surgical videos, achieving mean average precision (mAP) ranging from 4.2% to 38.1%.
arXiv Detail & Related papers (2022-04-10T18:51:55Z) - Multimodal Semantic Scene Graphs for Holistic Modeling of Surgical
Procedures [70.69948035469467]
We take advantage of the latest computer vision methodologies for generating 3D graphs from camera views.
We then introduce the Multimodal Semantic Graph Scene (MSSG) which aims at providing unified symbolic and semantic representation of surgical procedures.
arXiv Detail & Related papers (2021-06-09T14:35:44Z) - Relational Graph Learning on Visual and Kinematics Embeddings for
Accurate Gesture Recognition in Robotic Surgery [84.73764603474413]
We propose a novel online approach of multi-modal graph network (i.e., MRG-Net) to dynamically integrate visual and kinematics information.
The effectiveness of our method is demonstrated with state-of-the-art results on the public JIGSAWS dataset.
arXiv Detail & Related papers (2020-11-03T11:00:10Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.