Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact
- URL: http://arxiv.org/abs/2504.02735v2
- Date: Wed, 16 Apr 2025 15:51:41 GMT
- Title: Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact
- Authors: Manh Pham Hung, Matthew Yiwen Ho, Yiming Zhang, Dimitris Spathis, Aaqib Saeed, Dong Ma,
- Abstract summary: Photoplethysmography is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings.<n>While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions can distort waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy.<n>In this work, we propose CP-, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology.
- Score: 14.10775902843149
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.
Related papers
- Recovering Pulse Waves from Video Using Deep Unrolling and Deep Equilibrium Models [45.94962431110573]
Camera-based monitoring of vital signs, also known as imaging photoplethysmography (i), has seen applications in driver-monitoring, affective computing, and more.
We introduce methods that combine signal processing and deep learning methods in an inverse problem.
arXiv Detail & Related papers (2025-03-21T16:11:21Z) - TAU: Modeling Temporal Consistency Through Temporal Attentive U-Net for PPG Peak Detection [1.9518933807303265]
Photoplethysmography ( PPG) sensors have been widely used in consumer wearable devices to monitor heart rates (HR) and heart rate variability (HRV)<n>Despite the prevalence, PPG signals can be contaminated by motion artifacts induced from daily activities.<n>We propose the Temporal Attentive U-Net, i.e., TAU, to accurately detect peaks from PPG signals.
arXiv Detail & Related papers (2025-03-13T14:45:08Z) - Finger-to-Chest Style Transfer-assisted Deep Learning Method For Photoplethysmogram Waveform Restoration with Timing Preservation [1.0470286407954037]
We propose a style transfer-assisted cycle-consistent generative adversarial network, called starGAN, to efficiently restore chest-acquired PPG signals.<n>Two identical devices are adopted, one sensor to collect the PPG signal on the chest considered to feature low quality and undergoing restoration, and another sensor to obtain a high-quality PPG signal measured on the finger.
arXiv Detail & Related papers (2025-03-11T09:38:44Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [53.2981100111204]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - Leveraging Cardiovascular Simulations for In-Vivo Prediction of Cardiac Biomarkers [43.17768785084301]
We train an amortized neural posterior estimator on a newly built large dataset of cardiac simulations.
We incorporate elements modeling effects to better align simulated data with real-world measurements.
The proposed framework can further integrate in-vivo data sources to refine its predictive capabilities on real-world data.
arXiv Detail & Related papers (2024-12-23T13:05:17Z) - Analyzing Participants' Engagement during Online Meetings Using Unsupervised Remote Photoplethysmography with Behavioral Features [50.82725748981231]
Engagement measurement finds application in healthcare, education, services.
Use of physiological and behavioral features is viable, but impracticality of traditional physiological measurement arises due to the need for contact sensors.
We demonstrate the feasibility of the unsupervised photoplethysmography (rmography) as an alternative for contact sensors.
arXiv Detail & Related papers (2024-04-05T20:39:16Z) - PPG-to-ECG Signal Translation for Continuous Atrial Fibrillation Detection via Attention-based Deep State-Space Modeling [11.617950008187366]
Photoplethysmography ( PPG) is a cost-effective and non-invasive technique that utilizes optical methods to measure cardiac physiology.
Here, we propose a subject-independent attention-based deep state-space model (ADSSM) to translate PPG signals to corresponding ECG waveforms.
arXiv Detail & Related papers (2023-09-27T03:07:46Z) - Personalised and Adjustable Interval Type-2 Fuzzy-Based PPG Quality
Assessment for the Edge [0.1433758865948252]
The presented system has the potential to enable ultra-low complexity and real-time PPG quality assessment.
The proposed system obtained up to 93.72% for average accuracy during validation.
arXiv Detail & Related papers (2023-09-23T19:35:00Z) - Quality Assessment of Photoplethysmography Signals For Cardiovascular
Biomarkers Monitoring Using Wearable Devices [0.0]
Photoplethysmography is a non-invasive technology that measures changes in blood volume in the microvascular bed of tissue.
Photoplethysmography allows for the assessment of parameters that can indicate conditions such as vasoconstriction or vasodilation.
arXiv Detail & Related papers (2023-07-17T18:26:57Z) - A Conditional Flow Variational Autoencoder for Controllable Synthesis of
Virtual Populations of Anatomy [76.20367415712867]
We propose a conditional variational autoencoder (cVAE) with normalising flows to boost the flexibility and complexity of the approximate posterior learnt.
We demonstrate the performance of our conditional flow VAE using a data set of cardiac left ventricles acquired from 2360 patients.
arXiv Detail & Related papers (2023-06-26T13:23:52Z) - PhysFormer: Facial Video-based Physiological Measurement with Temporal
Difference Transformer [55.936527926778695]
Recent deep learning approaches focus on mining subtle r clues using convolutional neural networks with limited-temporal receptive fields.
In this paper, we propose the PhysFormer, an end-to-end video transformer based architecture.
arXiv Detail & Related papers (2021-11-23T18:57:11Z) - Lung Cancer Lesion Detection in Histopathology Images Using Graph-Based
Sparse PCA Network [93.22587316229954]
We propose a graph-based sparse principal component analysis (GS-PCA) network, for automated detection of cancerous lesions on histological lung slides stained by hematoxylin and eosin (H&E)
We evaluate the performance of the proposed algorithm on H&E slides obtained from an SVM K-rasG12D lung cancer mouse model using precision/recall rates, F-score, Tanimoto coefficient, and area under the curve (AUC) of the receiver operator characteristic (ROC)
arXiv Detail & Related papers (2021-10-27T19:28:36Z) - Motion Artifact Reduction In Photoplethysmography For Reliable Signal
Selection [5.264561559435017]
Photoplethysmography ( PPG) is a non-invasive and economical technique to extract vital signs of the human body.
It is sensitive to motion which can corrupt the signal's quality.
It is valuable to collect realistic PPG signals while performing Activities of Daily Living (ADL) to develop practical signal denoising and analysis methods.
arXiv Detail & Related papers (2021-09-06T21:53:56Z) - Video-based Remote Physiological Measurement via Cross-verified Feature
Disentangling [121.50704279659253]
We propose a cross-verified feature disentangling strategy to disentangle the physiological features with non-physiological representations.
We then use the distilled physiological features for robust multi-task physiological measurements.
The disentangled features are finally used for the joint prediction of multiple physiological signals like average HR values and r signals.
arXiv Detail & Related papers (2020-07-16T09:39:17Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.