Earth's field diamond vector magnetometry with isotropic magnetic flux concentrators
- URL: http://arxiv.org/abs/2507.00215v1
- Date: Mon, 30 Jun 2025 19:35:06 GMT
- Title: Earth's field diamond vector magnetometry with isotropic magnetic flux concentrators
- Authors: Maziar Saleh Ziabari, Nazanin Mosavian, Ilja Fescenko, Yaser Silani, Bryan A. Richards, Andris Berzins, Maxwell D. Aiello, Keith A. Lidke, Andrey Jarmola, Janis Smits, Victor M. Acosta,
- Abstract summary: Vector magnetometers based on the optically detected magnetic resonance (ODMR) of nitrogen-vacancy centers in diamond are being developed for applications such as navigation and geomagnetism.<n>Here, we experimentally investigate a potential solution of using an isotropic, three-dimensional magnetic flux concentrator to amplify Earth's field without altering its direction.<n>We track the stability of the magnetometer over six hours and observe variations less than or approximately 40 nT/hour, limited by temperature drift.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Vector magnetometers based on the optically detected magnetic resonance (ODMR) of nitrogen-vacancy centers in diamond are being developed for applications such as navigation and geomagnetism. However, at low magnetic fields, such as that on Earth (~50 {\mu}T), diamond magnetometers suffer from spectral congestion whereby ODMR peaks are not easily resolved. Here, we experimentally investigate a potential solution of using an isotropic, three-dimensional magnetic flux concentrator to amplify Earth's field without altering its direction. The concentrator consists of six ferrite cones, in a face-centered cubic arrangement, centered about a diamond. We vary the direction of a 50 {\mu}T applied field and record and fit the resulting ODMR spectra. By comparing the fitted fields to those of a reference fluxgate magnetometer, we characterize the angular response of the diamond magnetometer and quantify absolute errors in the field magnitude and angle. We find that the enhancement factor is nearly isotropic, with a mean of 19.05 and a standard deviation of 0.16, when weighted by solid angle coverage. Gradient broadening of the ODMR lines is sufficiently small that the spectra are well resolved for nearly all field directions, alleviating spectral congestion. For ~98% of the total 4{\pi} solid angle, Cram\'er-Rao lower bounds for magnetic field estimation uncertainty are within a factor of 2 of those of the fully-resolved case, indicating minimal deadzones. We track the stability of the magnetometer over six hours and observe variations less than or approximately 40 nT/hour, limited by temperature drift. Our study presents a new route for diamond vector magnetometry at Earth's field, with potential applications in geomagnetic surveys, anomaly detection, and navigation.
Related papers
- Bias-field-free operation of nitrogen-vacancy ensembles in diamond for accurate vector magnetometry [0.0]
Nitrogen-vacancy (NV) center spin ensembles offer a promising solution for high-sensitivity vector magnetometry.<n> bias magnetic field typically used to separate signals from each NV orientation introduces inaccuracy from drifts in permanent magnets or coils.<n>We present a novel bias-field-free approach that labels the NV orientations via the direction of the microwave (MW) field in a variable-pulse-duration Ramsey sequence.
arXiv Detail & Related papers (2025-05-30T13:26:10Z) - Wideband covariance magnetometry below the diffraction limit [33.83310724797305]
We experimentally demonstrate a method for measuring correlations of wideband magnetic signals with spatial resolution below the optical diffraction limit.<n>Our technique employs two nitrogen-vacancy (NV) centers in diamond as nanoscale magnetometers.
arXiv Detail & Related papers (2025-05-01T03:01:48Z) - Chemically resolved nuclear magnetic resonance spectroscopy by longitudinal magnetization detection with a diamond magnetometer [0.0]
Non-inductive magnetometers based on solid-state spins offer a promising solution for small-volume nuclear magnetic resonance (NMR) detection.<n>We demonstrate a Ramsey-M_z protocol that uses Ramsey interferometry to convert an analyte's transverse spin precession into a longitudinal magnetization (M_z)<n>We perform NMR spectroscopy on a 1 nL detection volume of ethanol and resolve the chemical shift structure with negligible distortion.
arXiv Detail & Related papers (2025-03-04T00:16:05Z) - Discovery of ST2 centers in natural and CVD diamond [34.82692226532414]
The ST2 center is an optically addressable point defect in diamond.<n>We map out its basic optical characteristics, reveal its electronic level structure, and quantify the intrinsic transition rates.<n>This finding establishes the ST2 center as a highly promising candidate for nanoscale quantum sensing.
arXiv Detail & Related papers (2024-12-31T17:54:29Z) - Vector Magnetometry Using Shallow Implanted NV Centers in Diamond with Waveguide-Assisted Dipole Excitation and Readout [33.221915954445855]
Nitrogen-Vacancy (NV) centers in diamond require scalable integration of 3D waveguides into diamond substrates.<n>We develop a sensing array device with an ensemble of shallow implanted NV centers integrated with arrays of laser-written waveguides for excitation and readout of NV signals.
arXiv Detail & Related papers (2024-07-26T12:55:25Z) - Microscale Fiber-Integrated Vector Magnetometer with On-Tip Field Biasing using NV Ensembles in Diamond Microcystals [0.0]
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution.
We present a novel approach that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field.
We demonstrate the measurement of vector magnetic fields in the full solid angle with a shot-noise limited sensitivity of $19.4:textrmnT/Hz1/2$ and microscale spatial resolution.
arXiv Detail & Related papers (2024-04-22T11:20:10Z) - Imaging magnetism evolution of magnetite to megabar pressure range with
quantum sensors in diamond anvil cell [57.91882523720623]
We develop an in-situ magnetic detection technique at megabar pressures with high sensitivity and sub-microscale spatial resolution.
We observe the macroscopic magnetic transition of Fe3O4 in the megabar pressure range from strong ferromagnetism (alpha-Fe3O4) to weak ferromagnetism (beta-Fe3O4) and finally to non-magnetism (gamma-Fe3O4)
The presented method can potentially investigate the spin-orbital coupling and magnetism-superconductivity competition in magnetic systems.
arXiv Detail & Related papers (2023-06-13T15:19:22Z) - Pulsed Vector Atomic Magnetometer Using an Alternating Fast-Rotating Field [3.3973386812990904]
We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed $87$Rb scalar atomic magnetometer.<n> operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 $mathrmfT/sqrtHz$ (0.7 parts per billion) and angular resolutions of 6 $mathrmnrad/sqrtHz$ at a 50 $mu$T Earth field strength.
arXiv Detail & Related papers (2023-04-01T03:25:22Z) - High-resolution spectroscopy of a single nitrogen-vacancy defect at zero
magnetic field [0.3848364262836075]
We report a study of high-resolution microwave spectroscopy of nitrogen-vacancy centers in diamond crystals at and around zero magnetic field.
We observe characteristic splitting and transition imbalance of the hyperfine transitions, which originate from level anti-crossings in the presence of a transverse effective field.
Our results are of importance for the optimization of the experimental conditions for the polarization-selective microwave excitation of spin-1 systems in zero or weak magnetic fields.
arXiv Detail & Related papers (2022-06-30T02:49:49Z) - DC Quantum Magnetometry Below the Ramsey Limit [68.8204255655161]
We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional $Tast$-limited dc magnetometry by more than an order of magnitude.
We used nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed.
arXiv Detail & Related papers (2022-03-27T07:32:53Z) - Multi-Center Magnon Excitations Open the Entire Brillouin Zone to
Terahertz Magnetometry of Quantum Magnets [42.72559625804617]
The magnon density of states can be accessed over the entire Brillouin zone through three-center magnon excitations.
The results of THz time-domain experiments agree remarkably well with linear spin-wave theory.
arXiv Detail & Related papers (2022-03-08T19:04:24Z) - Surpassing the Energy Resolution Limit with ferromagnetic torque sensors [55.41644538483948]
We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit.
We find that the Energy Resolution Limit (ERL), pointed out in recent literature, can be surpassed by many orders of magnitude.
arXiv Detail & Related papers (2021-04-29T15:44:12Z) - Ferromagnetic Gyroscopes for Tests of Fundamental Physics [49.853792068336034]
A ferromagnetic gyroscope (FG) is a ferromagnet whose angular momentum is dominated by electron spin polarization and that will precess under the action of an external torque.
We model and analyze FG dynamics and sensitivity, focusing on practical schemes for experimental realization.
arXiv Detail & Related papers (2020-10-17T07:13:50Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.