Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy diamond
- URL: http://arxiv.org/abs/2511.11561v1
- Date: Fri, 14 Nov 2025 18:54:05 GMT
- Title: Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy diamond
- Authors: Reginald Wilcox, David Phillips, Matthew Steinecker, Erik Eisenach, Corey Hawkins, Linh Pham, Jennifer Schloss, Dirk Englund, Danielle Braje,
- Abstract summary: $4$-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity.<n>MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation.
- Score: 0.13844776505474532
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: We demonstrate $4π$-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/$\sqrt{\mathrm{Hz}}$ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/$\sqrt{\mathrm{Hz}}$.
Related papers
- QDsiM: A Noise-Aware Simulation Toolkit for Quantum Diamond Microscope [10.814244923718405]
The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry.<n>We present a comprehensive simulation framework, for continuous-wave wide-field ODMR in NV-center ensembles.
arXiv Detail & Related papers (2026-01-15T09:13:39Z) - Using NV centers in diamond to detect DC to very-low frequency magnetic fields [0.0]
We present a compact and portable tabletop magnetometer that utilizes negatively charged nitrogen-vacancy centers in diamond.<n>The experimentally measured magnetic field noise-floor is $approx 2.3textrmnTsqrttextrmHz$ while the calculated shot-noise-limited magnetic field sensitivity is $approx 585textrmpTsqrttextrmHz$ when excited with a continuous wave laser at 0.5W.
arXiv Detail & Related papers (2025-12-30T14:57:37Z) - Robust AC vector sensing at zero magnetic field with pentacene [45.7221176995052]
Quantum sensors based on electronic spins have emerged as powerful probes of microwave-frequency fields.<n>Here, we demonstrate microwave vector magnetometry using the photoexcited spin triplet of pentacene molecules.
arXiv Detail & Related papers (2025-12-06T03:49:12Z) - High-Sensitivity NV Ensemble Imaging via AOD-Based Raster Scanning and Photodetection [33.72751145910978]
We present a technique based on an ensemble of nitrogen-vacancy centers in diamond capable of detecting magnetic fields with high resolution.<n>To demonstrate its capabilities we image time-varying magnetic fields from a microelectrode in a quasi-second medium with sub-millisecond temporal resolution.<n>This approach enables flexible spatial sampling and achieves with our diamond nT$cdot$Hz$-1/2$ per pixel sensitivity, making it well suited for detecting weak, dynamic magnetic fields in biological and other complex systems.
arXiv Detail & Related papers (2025-12-01T17:13:37Z) - Optimising germanium hole spin qubits with a room-temperature magnet [33.7054351451505]
Germanium spin qubits exhibit strong spin-orbit interaction, which allow for high-fidelity qubit control.<n>Superconducting vector magnets are often used to minimize dephasing due to hyperfine interactions.<n>We explore whether a permanent magnet outside the cryostat can be used as an alternative.
arXiv Detail & Related papers (2025-07-04T08:48:57Z) - Wideband covariance magnetometry below the diffraction limit [33.83310724797305]
We experimentally demonstrate a method for measuring correlations of wideband magnetic signals with spatial resolution below the optical diffraction limit.<n>Our technique employs two nitrogen-vacancy (NV) centers in diamond as nanoscale magnetometers.
arXiv Detail & Related papers (2025-05-01T03:01:48Z) - Two-media laser threshold magnetometry: A magnetic-field-dependent laser threshold [29.039962620404822]
Nitrogen-vacancy (NV) centers in diamond are a promising platform for high-precision magnetometry.<n>Laser threshold magnetometry (LTM) exploits stimulated emission of NV centers by placing an NV-doped diamond inside an optical cavity.
arXiv Detail & Related papers (2025-04-11T11:56:17Z) - Vector Magnetometry Using Shallow Implanted NV Centers in Diamond with Waveguide-Assisted Dipole Excitation and Readout [33.221915954445855]
Nitrogen-Vacancy (NV) centers in diamond require scalable integration of 3D waveguides into diamond substrates.<n>We develop a sensing array device with an ensemble of shallow implanted NV centers integrated with arrays of laser-written waveguides for excitation and readout of NV signals.
arXiv Detail & Related papers (2024-07-26T12:55:25Z) - Microscale Fiber-Integrated Vector Magnetometer with On-Tip Field Biasing using NV Ensembles in Diamond Microcystals [0.0]
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution.
We present a novel approach that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field.
We demonstrate the measurement of vector magnetic fields in the full solid angle with a shot-noise limited sensitivity of $19.4:textrmnT/Hz1/2$ and microscale spatial resolution.
arXiv Detail & Related papers (2024-04-22T11:20:10Z) - Fiber-coupled Diamond Magnetometry with an Unshielded 30
pT/$\sqrt{\textrm{Hz}}$ Sensitivity [0.0]
We present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $pm$ 10) pT/$sqrttextrmHz$ in a (10 - 500)-Hz frequency range.
This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias field alignment, microwave and lock-in amplifier (LIA) parameter optimisation, as well as a balanced hyperfine excitation scheme.
The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with
arXiv Detail & Related papers (2022-11-16T19:35:51Z) - Measuring the magnon-photon coupling in shaped ferromagnets: tuning of
the resonance frequency [50.591267188664666]
cavity photons and ferromagnetic spins excitations can exchange information coherently in hybrid architectures.
Speed enhancement is usually achieved by optimizing the geometry of the electromagnetic cavity.
We show that the geometry of the ferromagnet plays also an important role, by setting the fundamental frequency of the magnonic resonator.
arXiv Detail & Related papers (2022-07-08T11:28:31Z) - Zero-field magnetometry using hyperfine-biased nitrogen-vacancy centers
near diamond surfaces [5.189354274663932]
We show that a 130 MHz coupling from a first-shell 13C nuclear spin can provide an effective bias field to an NV center spin.
With the charge noises suppressed by the strong hyperfine field, the ac magnetometry under zero field also reaches the limit set by decoherence.
The hyperfine-bias enhanced zero-field magnetometry can be combined with dynamical decoupling to enhance single-molecule magnetic resonance spectroscopy.
arXiv Detail & Related papers (2021-09-12T06:37:52Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.