Early and Prediagnostic Detection of Pancreatic Cancer from Computed Tomography
- URL: http://arxiv.org/abs/2601.22134v1
- Date: Thu, 29 Jan 2026 18:55:23 GMT
- Title: Early and Prediagnostic Detection of Pancreatic Cancer from Computed Tomography
- Authors: Wenxuan Li, Pedro R. A. S. Bassi, Lizhou Wu, Xinze Zhou, Yuxuan Zhao, Qi Chen, Szymon Plotka, Tianyu Lin, Zheren Zhu, Marisa Martin, Justin Caskey, Shanshan Jiang, Xiaoxi Chen, Jaroslaw B. Ćwikla, Artur Sankowski, Yaping Wu, Sergio Decherchi, Andrea Cavalli, Chandana Lall, Cristian Tomasetti, Yaxing Guo, Xuan Yu, Yuqing Cai, Hualin Qiao, Jie Bao, Chenhan Hu, Ximing Wang, Arkadiusz Sitek, Kai Ding, Heng Li, Meiyun Wang, Dexin Yu, Guang Zhang, Yang Yang, Kang Wang, Alan L. Yuille, Zongwei Zhou,
- Abstract summary: Pancreatic ductal adenocarcinoma (PDAC) is often detected at a late and inoperable stage.<n>We developed an automated system named ePAI (early Pancreatic cancer detection with Artificial Intelligence)<n>ePAI successfully detected and localized PDACs in 75 of 159 patients, with a median lead time of 347 days before clinical diagnosis.
- Score: 46.596419554048225
- License: http://creativecommons.org/licenses/by-nc-sa/4.0/
- Abstract: Pancreatic ductal adenocarcinoma (PDAC), one of the deadliest solid malignancies, is often detected at a late and inoperable stage. Retrospective reviews of prediagnostic CT scans, when conducted by expert radiologists aware that the patient later developed PDAC, frequently reveal lesions that were previously overlooked. To help detecting these lesions earlier, we developed an automated system named ePAI (early Pancreatic cancer detection with Artificial Intelligence). It was trained on data from 1,598 patients from a single medical center. In the internal test involving 1,009 patients, ePAI achieved an area under the receiver operating characteristic curve (AUC) of 0.939-0.999, a sensitivity of 95.3%, and a specificity of 98.7% for detecting small PDAC less than 2 cm in diameter, precisely localizing PDAC as small as 2 mm. In an external test involving 7,158 patients across 6 centers, ePAI achieved an AUC of 0.918-0.945, a sensitivity of 91.5%, and a specificity of 88.0%, precisely localizing PDAC as small as 5 mm. Importantly, ePAI detected PDACs on prediagnostic CT scans obtained 3 to 36 months before clinical diagnosis that had originally been overlooked by radiologists. It successfully detected and localized PDACs in 75 of 159 patients, with a median lead time of 347 days before clinical diagnosis. Our multi-reader study showed that ePAI significantly outperformed 30 board-certified radiologists by 50.3% (P < 0.05) in sensitivity while maintaining a comparable specificity of 95.4% in detecting PDACs early and prediagnostic. These findings suggest its potential of ePAI as an assistive tool to improve early detection of pancreatic cancer.
Related papers
- Neural Discrete Representation Learning for Sparse-View CBCT Reconstruction: From Algorithm Design to Prospective Multicenter Clinical Evaluation [64.42236775544579]
Cone beam computed tomography (CBCT)-guided puncture has become an established approach for diagnosing and treating thoracic tumours.<n>DeepPriorCBCT is a three-stage deep learning framework that achieves diagnostic-grade reconstruction using only one-sixth of the conventional radiation dose.
arXiv Detail & Related papers (2025-11-30T12:45:02Z) - Pillar-0: A New Frontier for Radiology Foundation Models [41.640120966890954]
We introduce Pillar-0, a radiology foundation model pretrained on 42,990 abdomen-pelvis CTs, 86,411 chest CTs, 14,348 head CTs, and 11,543 breast MRIs.<n>Pillar-0 achieves mean AUROCs of 86.4, 88.0, 90.1, and 82.9, outperforming MedGemma (Google), MedImageInsight (Microsoft), Lingshu (Alibaba), and Merlin (Stanford) by 7.8-15.8 AUROC points and ranking best in 87.2% (319/366) tasks.
arXiv Detail & Related papers (2025-11-21T21:50:34Z) - Closing the Performance Gap Between AI and Radiologists in Chest X-Ray Reporting [40.40577855417923]
We introduce MAIRA-X, a clinically evaluated multimodal AI model for longitudinal chest X-ray report generation.<n>A novel L&T-specific metrics framework was developed to assess accuracy in reporting attributes such as type, longitudinal change and placement.<n>Our results suggest MAIRA-X can effectively assist radiologists, particularly in high-volume clinical settings.
arXiv Detail & Related papers (2025-11-21T10:53:26Z) - Prostate Cancer Screening with Artificial Intelligence-Enhanced Micro-Ultrasound: A Comparative Study with Traditional Methods [3.57040780961711]
Micro-ultrasound (micro-US) is a novel imaging modality with diagnostic accuracy comparable to MRI for detecting prostate cancer (csPCa)<n>We investigated whether artificial intelligence (AI) interpretation of micro-US can outperform clinical screening methods using PSA and digital rectal examination (DRE)
arXiv Detail & Related papers (2025-05-27T15:47:38Z) - AI-assisted Early Detection of Pancreatic Ductal Adenocarcinoma on Contrast-enhanced CT [7.18570106703978]
Pancreatic ductal adenocarcinoma (PDAC) is one of the most common and aggressive pancreatic cancer.<n>In this work, we develop a coarse-to-fine approach to detect PDAC on contrast-enhanced CT scans.
arXiv Detail & Related papers (2025-03-13T05:31:18Z) - Deep Radiomics Detection of Clinically Significant Prostate Cancer on Multicenter MRI: Initial Comparison to PI-RADS Assessment [0.0]
This study analyzed biparametric (T2W and DW) prostate MRI sequences of 615 patients (mean age, 63.1 +/- 7 years) from four datasets acquired between 2010 and 2020.
Deep radiomics machine learning model achieved comparable performance to PI-RADS assessment in csPCa detection at the patient-level but not at the lesion-level.
arXiv Detail & Related papers (2024-10-21T17:41:58Z) - A Deep Learning System for Rapid and Accurate Warning of Acute Aortic Syndrome on Non-contrast CT in China [34.1445580369382]
Aortic CT angiography (CTA) is the imaging protocol of choice in patients with suspected AAS.<n>Due to economic and workflow constraints in China, the majority of suspected patients initially undergo non-contrast CT as the initial imaging testing.<n>We present an artificial intelligence-based warning system, iAorta, using non-contrast CT for AAS identification.
arXiv Detail & Related papers (2024-06-14T02:15:09Z) - Detection of subclinical atherosclerosis by image-based deep learning on chest x-ray [86.38767955626179]
Deep-learning algorithm to predict coronary artery calcium (CAC) score was developed on 460 chest x-ray.
The diagnostic accuracy of the AICAC model assessed by the area under the curve (AUC) was the primary outcome.
arXiv Detail & Related papers (2024-03-27T16:56:14Z) - Identification of Ischemic Heart Disease by using machine learning
technique based on parameters measuring Heart Rate Variability [50.591267188664666]
In this study, 18 non-invasive features (age, gender, left ventricular ejection fraction and 15 obtained from HRV) of 243 subjects were used to train and validate a series of several ANN.
The best result was obtained using 7 input parameters and 7 hidden nodes with an accuracy of 98.9% and 82% for the training and validation dataset.
arXiv Detail & Related papers (2020-10-29T19:14:41Z) - Integrative Analysis for COVID-19 Patient Outcome Prediction [53.11258640541513]
We combine radiomics of lung opacities and non-imaging features from demographic data, vital signs, and laboratory findings to predict need for intensive care unit admission.
Our methods may also be applied to other lung diseases including but not limited to community acquired pneumonia.
arXiv Detail & Related papers (2020-07-20T19:08:50Z) - Dual-Sampling Attention Network for Diagnosis of COVID-19 from Community
Acquired Pneumonia [46.521323145636906]
We develop a dual-sampling attention network to automatically diagnose COVID-19 from the community acquired pneumonia (CAP) in chest computed tomography (CT)
In particular, we propose a novel online attention module with a 3D convolutional network (CNN) to focus on the infection regions in lungs when making decisions of diagnoses.
Our algorithm can identify the COVID-19 images with the area under the receiver operating characteristic curve (AUC) value of 0.944, accuracy of 87.5%, sensitivity of 86.9%, specificity of 90.1%, and F1-score of 82.0%.
arXiv Detail & Related papers (2020-05-06T09:56:51Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.