DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising
- URL: http://arxiv.org/abs/2603.07759v1
- Date: Sun, 08 Mar 2026 18:31:22 GMT
- Title: DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising
- Abstract summary: Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD)<n>Short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging.<n>We propose DECADE, an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames.
- Score: 10.409009612596714
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.
Related papers
- Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy [9.330524424029553]
We propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising.<n>Our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines.
arXiv Detail & Related papers (2026-09-15T06:13:59Z) - DeVAR: Low-Dose CT Denoising via Visual Autoregressive Modeling [14.938419722549575]
Low-dose CT (LDCT) protocols reduce radiation risks but inevitably suffer from severe noise and artifacts that compromise diagnostic accuracy.<n>We propose a novel generative framework that applies visual autore modeling to LDCT denoising for the first time.<n>Our hybrid NDCT decoder seamlessly integrates continuous and discrete latents to reconstruct high-fidelity, detail-preserved images.
arXiv Detail & Related papers (2026-06-26T09:55:37Z) - An Attention-Based Denoising Model for Diffusion Weighted Imaging [0.9772661758518332]
When the scan time is reduced, the image quality often suffers, leading to increased noise in the scans.<n>We propose a noise-aware attention-driven denoising framework that integrates hierarchical Swin Transformer window attention with transformer-based multi-dimensional gated refinement for DWI restoration.<n>Our model achieves a mean PSNR of 33.69dB and SSIM of 0.8539 across noise levels from 1% to 15%, while maintaining stable behavior under severe noise conditions.
arXiv Detail & Related papers (2026-06-02T16:59:09Z) - Enhancing ECG Classification Robustness with Lightweight Unsupervised Anomaly Detection Filters [39.9470953186283]
Continuous electrocardiogram (ECG) monitoring via wearables offers significant potential for early cardiovascular disease (CVD) detection.<n> deploying deep learning models for automated analysis in resource-constrained environments faces reliability challenges due to Out-of-Distribution data.<n>This paper explores Unsupervised Anomaly Detection (UAD) as an independent, upstream filtering mechanism to improve robustness.
arXiv Detail & Related papers (2025-10-30T13:54:37Z) - Conditional Denoising Diffusion Model-Based Robust MR Image Reconstruction from Highly Undersampled Data [11.174208209806073]
Undersampling strategies can accelerate image acquisition, but they often result in image artifacts and degraded quality.<n>Recent diffusion models have shown promise for reconstructing high-fidelity images from undersampled data by learning powerful image priors.<n>We introduce a conditional denoising diffusion framework with iterative data-consistency correction.
arXiv Detail & Related papers (2025-10-07T18:01:08Z) - MAN: Latent Diffusion Enhanced Multistage Anti-Noise Network for Efficient and High-Quality Low-Dose CT Image Denoising [8.912550844312177]
We introduce MAN, a Latent Diffusion Enhanced Multistage Anti-Noise Network for Efficient and High-Quality Low-Dose CT Image Denoising task.<n>Our method operates in a compressed latent space via a perceptually-optimized autoencoder.<n>Our work demonstrates a practical path forward for advanced generative models in medical imaging.
arXiv Detail & Related papers (2025-09-28T03:13:39Z) - EqDiff-CT: Equivariant Conditional Diffusion model for CT Image Synthesis from CBCT [43.92108185590778]
Cone-beam computed tomography (CBCT) is widely used for imageguided radiotherapy (IGRT)<n>We propose a novel diffusion-based conditional generative model, coined EqDiff-CT, to synthesize high-quality CT images from CBCT.
arXiv Detail & Related papers (2025-09-26T05:51:59Z) - Noise-Inspired Diffusion Model for Generalizable Low-Dose CT Reconstruction [37.71732274622662]
We propose a noise-inspired diffusion model for generalizable low-dose CT reconstruction, termed NEED, which tailors diffusion models for noise characteristics of each domain.<n>By cascading these two diffusion models for dual-domain reconstruction, our NEED requires only normal-dose data for training and can be effectively extended to various unseen dose levels during testing.
arXiv Detail & Related papers (2025-06-27T08:24:55Z) - RELD: Regularization by Latent Diffusion Models for Image Restoration [41.602636013364574]
We introduce an approach that integrates a Latent Diffusion Model, trained for the denoising task, into a variational framework using Half-Quadratic Splitting.<n>The proposed strategy, called Regularization by Latent Denoising (RELD), is then tested on a dataset of natural images.
arXiv Detail & Related papers (2025-03-28T16:04:21Z) - Fed-NDIF: A Noise-Embedded Federated Diffusion Model For Low-Count Whole-Body PET Denoising [16.937074760667745]
Low-count positron emission tomography (LCPET) imaging can reduce patients' exposure to radiation but often suffers from increased image noise and reduced lesion detectability.<n> Diffusion models have shown promise in LCPET denoising for recovering degraded image quality.<n>We propose a novel noise-embedded federated learning diffusion model (Fed-NDIF) to address these challenges.
arXiv Detail & Related papers (2025-03-20T18:37:46Z) - Cycle-Constrained Adversarial Denoising Convolutional Network for PET Image Denoising: Multi-Dimensional Validation on Large Datasets with Reader Study and Real Low-Dose Data [9.160782425067712]
We propose a Cycle-versa Adrial Denoising Convolutional Network (Cycle-DCN) to reconstruct full-dose-quality images from low-dose scans.
Experiments were conducted on a large dataset consisting of raw PET brain data from 1,224 patients.
Cycle-DCN significantly improves average Peak Signal-to-Noise Ratio (PSNR), SSIM, and Normalized Root Mean Square Error (NRMSE) across three dose levels.
arXiv Detail & Related papers (2024-10-31T04:34:28Z) - Unsupervised Training of a Dynamic Context-Aware Deep Denoising Framework for Low-Dose Fluoroscopic Imaging [6.130738760059542]
Fluoroscopy is critical for real-time X-ray visualization in medical imaging.
Low-dose images are compromised by noise, potentially affecting diagnostic accuracy.
We propose an unsupervised training framework for dynamic context-aware denoising of fluoroscopy image sequences.
arXiv Detail & Related papers (2024-10-29T13:39:31Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - CoreDiff: Contextual Error-Modulated Generalized Diffusion Model for
Low-Dose CT Denoising and Generalization [41.64072751889151]
Low-dose computed tomography (LDCT) images suffer from noise and artifacts due to photon starvation and electronic noise.
This paper presents a novel COntextual eRror-modulated gEneralized Diffusion model for low-dose CT (LDCT) denoising, termed CoreDiff.
arXiv Detail & Related papers (2023-04-04T14:13:13Z) - The role of noise in denoising models for anomaly detection in medical
images [62.0532151156057]
Pathological brain lesions exhibit diverse appearance in brain images.
Unsupervised anomaly detection approaches have been proposed using only normal data for training.
We show that optimization of the spatial resolution and magnitude of the noise improves the performance of different model training regimes.
arXiv Detail & Related papers (2023-01-19T21:39:38Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.