Quantum Magnetometers for Infrastructure Inspection and Monitoring
- URL: http://arxiv.org/abs/2604.03288v1
- Date: Wed, 25 Mar 2026 22:50:36 GMT
- Title: Quantum Magnetometers for Infrastructure Inspection and Monitoring
- Abstract summary: Damage in infrastructure is often hidden until it becomes costly or dangerous. Common examples include corrosion under insulation, early fatigue damage in steel, corrosion of embedded reinforcement, and abnormal current flow in batteries and power equipment.<n>Magnetic methods are attractive because they can sense through coatings, insulation, and concrete cover without couplants.<n>This review examines two room-temperature quantum receiver platforms: optically pumped atomic magnetometers (OPMs) and nitrogen-vacancy diamond magnetometers.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Damage in infrastructure is often hidden until it becomes costly or dangerous. Common examples include corrosion under insulation, early fatigue damage in steel, corrosion of embedded reinforcement, and abnormal current flow in batteries and power equipment. Magnetic methods are attractive because they can sense through coatings, insulation, and concrete cover without couplants, but field performance is often limited by lift-off, low-frequency drift, background magnetic noise, and the weak low-frequency response of pickup coils. This review examines two room-temperature quantum receiver platforms: optically pumped atomic magnetometers (OPMs) and nitrogen-vacancy (NV) diamond magnetometers. Rather than treating them as stand-alone sensors, we compare them as parts of a full measurement chain that includes source physics, geometry, readout, calibration, and interpretation. The literature is organized into four magnetic signal classes: driven induction responses, leakage fields in magnetic flux leakage inspection, passive self-fields linked to stress or corrosion, and fields produced by operational currents. OPMs are strongest for low-frequency, phase-referenced induction measurements, while NV sensors are strongest for near-surface field mapping, vector or gradient measurements, and differential current sensing in compact solid-state heads. Across all applications, deployment depends less on best-case sensitivity than on usable bandwidth, dynamic range, background rejection, geometry control, calibration, and validation. The clearest path to field use is therefore robust instrument engineering tied to qualification methods that reflect real inspection conditions.
Related papers
- AC magnetometry in the strong drive regime with NV centers in diamond [0.0]
Nitrogen-vacancy (NV) centers in diamond are a commonly-used platform for such studies.<n>We introduce a phase modulation protocol that cancels MW pulse detuning to leading order, and extends NV AC magnetometry into the strong drive field regime.
arXiv Detail & Related papers (2025-10-07T00:17:08Z) - Bias-field-free operation of nitrogen-vacancy ensembles in diamond for accurate vector magnetometry [0.0]
Nitrogen-vacancy center spin ensembles offer a promising solution for high-sensitivity vector magnetometry.<n> bias magnetic field typically used to separate signals from each NV orientation introduces inaccuracy from drifts in permanent magnets or coils.<n>We present a novel bias-field-free approach that labels the NV orientations via the direction of the microwave (MW) field in a variable-pulse-duration Ramsey sequence.
arXiv Detail & Related papers (2025-05-30T13:26:10Z) - Ferrimagnetic Oscillator Magnetometer [0.0]
The device exhibits a fixed, calibration-free response governed by the electronmagnetic gyro ratio.
The device achieves a minimum sensitivity of 100 fT/$sqrttextHz$ to AC magnetic fields of unknown phase.
arXiv Detail & Related papers (2023-05-31T15:21:57Z) - Engineering field-insensitive molecular clock transitions for symmetry
violation searches [2.5943586090617377]
We show that sensitivity to both external magnetic and electric fields can be simultaneously suppressed using engineered radio frequency, microwave, or two-photon transitions.
The method is compatible with traditional Ramsey measurements, offers internal co-magnetometry, and is useful for systems with large angular momentum.
arXiv Detail & Related papers (2023-04-26T20:38:00Z) - All-Optical Nuclear Quantum Sensing using Nitrogen-Vacancy Centers in
Diamond [52.77024349608834]
Microwave or radio-frequency driving poses a significant limitation for miniaturization, energy-efficiency and non-invasiveness of quantum sensors.
We overcome this limitation by demonstrating a purely optical approach to coherent quantum sensing.
Our results pave the way for highly compact quantum sensors to be employed for magnetometry or gyroscopy applications.
arXiv Detail & Related papers (2022-12-14T08:34:11Z) - A hybrid ferromagnetic transmon qubit: circuit design, feasibility and
detection protocols for magnetic fluctuations [45.82374977939355]
We show that the characteristic hysteretic behavior of the ferromagnetic barrier provides an alternative and intrinsically digital tuning of the qubit frequency by means of magnetic field pulses.
The possibility to use the qubit as a noise detector and its relevance to investigate the subtle interplay of magnetism and superconductivity is envisaged.
arXiv Detail & Related papers (2022-06-01T18:50:26Z) - DC Quantum Magnetometry Below the Ramsey Limit [68.8204255655161]
We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional $Tast$-limited dc magnetometry by more than an order of magnitude.
We used nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed.
arXiv Detail & Related papers (2022-03-27T07:32:53Z) - Probing quantum devices with radio-frequency reflectometry [68.48453061559003]
Radio-frequency reflectometry can measure changes in impedance even when their duration is extremely short, down to a microsecond or less.
Examples of reflectometry experiments include projective measurements of qubits and Majorana devices for quantum computing.
This book aims to introduce the readers to the technique, to review the advances to date and to motivate new experiments in fast quantum device dynamics.
arXiv Detail & Related papers (2022-02-21T20:14:21Z) - A background-free optically levitated charge sensor [50.591267188664666]
We introduce a new technique to model and eliminate dipole moment interactions limiting the performance of sensors employing levitated objects.
As a demonstration, this is applied to the search for unknown charges of a magnitude much below that of an electron.
As a by-product of the technique, the electromagnetic properties of the levitated objects can also be measured on an individual basis.
arXiv Detail & Related papers (2021-12-20T08:16:28Z) - Surpassing the Energy Resolution Limit with ferromagnetic torque sensors [55.41644538483948]
We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit.
We find that the Energy Resolution Limit (ERL), pointed out in recent literature, can be surpassed by many orders of magnitude.
arXiv Detail & Related papers (2021-04-29T15:44:12Z) - Cavity quantum electrodynamic readout of a solid-state spin sensor [0.0]
Solid-state spin sensors still lack a universal, high-fidelity readout technique.
We demonstrate high-fidelity, room-temperature readout of an ensemble of nitrogen-vacancy (NV) centers via strong coupling to a dielectric microwave cavity.
Our results pave a clear path to achieve unity readout fidelity of solid-state spin sensors through increased ensemble size, reduced spin-resonance linewidth, or improved cavity quality factor.
arXiv Detail & Related papers (2020-03-02T18:57:40Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.