Sampling Matters: The Effect of ECG Frequency on Deep Learning-Based Atrial Fibrillation Detection
- URL: http://arxiv.org/abs/2604.16437v1
- Date: Mon, 06 Apr 2026 20:34:42 GMT
- Title: Sampling Matters: The Effect of ECG Frequency on Deep Learning-Based Atrial Fibrillation Detection
- Abstract summary: We evaluate a standard 1-D Convolutional Neural Network (CNN) and a hybrid CNN-Long Short-Term Memory (LSTM) architecture under a rigorous patient-safe cross-validation framework.<n>Our analysis reveals that sampling frequency significantly impacts detection metrics in an architecture-dependent manner.<n>We conclude that ECG sampling frequency is a critical, underappreciated factor in arrhythmia detection.
- Score: 0.5618963890305396
- License: http://creativecommons.org/licenses/by-nc-sa/4.0/
- Abstract: Deep learning models for atrial fibrillation (AF) detection are increasingly trained on heterogeneous electrocardiogram (ECG) datasets with varying sampling frequencies, yet the specific consequences of these discrepancies on model performance, calibration, and robustness remain insufficiently characterized. To address this, we conducted a systematic benchmark using 12-lead, 10-second recordings from the PTB-XL dataset, resampled to target frequencies of 62, 100, 250, and 500 Hz, to evaluate a standard 1-D Convolutional Neural Network (CNN) and a hybrid CNN-Long Short-Term Memory (LSTM) architecture under a rigorous patient-safe cross-validation framework. Our analysis reveals that sampling frequency significantly impacts detection metrics in an architecture-dependent manner; the hybrid CNN-LSTM model demonstrated optimal performance and consistent calibration at intermediate frequencies (100-250 Hz), whereas the 1-D CNN baseline exhibited marked degradation in accuracy and sensitivity at 500 Hz, suggesting increased susceptibility to high-frequency noise. We conclude that ECG sampling frequency is a critical, underappreciated factor in arrhythmia detection, and future foundation models must explicitly control for temporal resolution to ensure clinical reliability and reproducibility.
Related papers
- TimeLAVA: Learning-Agnostic Data Valuation for Time Series [48.76711740818533]
TimeLAVA is a learning-agnostic framework that values temporal segments by their marginal contribution to minimize distributional discrepancy between evaluated and reference data.<n>We provide theoretical guarantees linking valuation to model-agnostic generalization and prove bounded sensitivity to contamination.
arXiv Detail & Related papers (2026-06-17T06:16:16Z) - Demographic-Aware Self-Supervised Anomaly Detection Pretraining for Equitable Rare Cardiac Diagnosis [45.00216485193071]
Rare cardiac anomalies are difficult to detect from electrocardiograms due to their long-tailed distribution.<n>We developed an AI-assisted two-stage ECG framework integrating self-supervised anomaly detection and demographic-aware representation learning.<n>Our method achieves an AUROC of 94.7% for rare anomalies and reduces the common-rare performance gap by 73%.
arXiv Detail & Related papers (2026-03-20T07:04:00Z) - Atrial Fibrillation Detection Using Machine Learning [3.5522386235856582]
Atrial fibrillation (AF) is a common cardiac arrhythmia and a major risk factor for ischemic stroke.<n>We present a 10-fold machine learning framework for AF detection from simultaneous photoplethysmogram (ECG) and ECG signals.
arXiv Detail & Related papers (2026-02-20T07:30:08Z) - H-Infinity Filter Enhanced CNN-LSTM for Arrhythmia Detection from Heart Sound Recordings [0.7394388288509157]
Early detection of heart arrhythmia can prevent severe future complications in cardiac patients.<n>Deep learning has emerged as a powerful tool to automate arrhythmia detection.<n>A novel CNN-H-Infinity-LSTM architecture is proposed to identify arrhythmic heart signals from heart sound recordings.
arXiv Detail & Related papers (2025-11-04T09:00:17Z) - TF-TransUNet1D: Time-Frequency Guided Transformer U-Net for Robust ECG Denoising in Digital Twin [16.693268731997996]
We propose TF-TransUNet1D, a novel one-dimensional deep neural network that integrates a U-Net-based encoder-decoder architecture with a Transformer encoder.<n>The model is designed to simultaneously capture local morphological features and long-range temporal dependencies.<n>By delivering high-precision denoising, this work bridges a critical gap in pre-processing pipelines for cardiac digital twins.
arXiv Detail & Related papers (2025-08-28T03:51:19Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - Consistency Trajectory Models: Learning Probability Flow ODE Trajectory of Diffusion [56.38386580040991]
Consistency Trajectory Model (CTM) is a generalization of Consistency Models (CM)
CTM enables the efficient combination of adversarial training and denoising score matching loss to enhance performance.
Unlike CM, CTM's access to the score function can streamline the adoption of established controllable/conditional generation methods.
arXiv Detail & Related papers (2023-10-01T05:07:17Z) - Continuous time recurrent neural networks: overview and application to
forecasting blood glucose in the intensive care unit [56.801856519460465]
Continuous time autoregressive recurrent neural networks (CTRNNs) are a deep learning model that account for irregular observations.
We demonstrate the application of these models to probabilistic forecasting of blood glucose in a critical care setting.
arXiv Detail & Related papers (2023-04-14T09:39:06Z) - Classification of ECG based on Hybrid Features using CNNs for Wearable
Applications [2.0999222360659604]
We demonstrate improved performance for ECG classification using hybrid features and three different models.
An RR interval features based model proposed in this work achieved an accuracy of 98.98%, which is an improvement over the baseline model.
Another model combining the frequency features and the RR interval features was developed, which achieved a high accuracy of 99% with good sustained performance in noisy environments.
arXiv Detail & Related papers (2022-06-14T12:14:40Z) - Generalizing electrocardiogram delineation: training convolutional
neural networks with synthetic data augmentation [63.51064808536065]
Existing databases for ECG delineation are small, being insufficient in size and in the array of pathological conditions they represent.
This article delves has two main contributions. First, a pseudo-synthetic data generation algorithm was developed, based in probabilistically composing ECG traces given "pools" of fundamental segments, as cropped from the original databases, and a set of rules for their arrangement into coherent synthetic traces.
Second, two novel segmentation-based loss functions have been developed, which attempt at enforcing the prediction of an exact number of independent structures and at producing closer segmentation boundaries by focusing on a reduced number of samples.
arXiv Detail & Related papers (2021-11-25T10:11:41Z) - DENS-ECG: A Deep Learning Approach for ECG Signal Delineation [15.648061765081264]
This paper proposes a deep learning model for real-time segmentation of heartbeats.
The proposed algorithm, named as the DENS-ECG algorithm, combines convolutional neural network (CNN) and long short-term memory (LSTM) model.
arXiv Detail & Related papers (2020-05-18T13:13:41Z) - ECG-DelNet: Delineation of Ambulatory Electrocardiograms with Mixed
Quality Labeling Using Neural Networks [69.25956542388653]
Deep learning (DL) algorithms are gaining weight in academic and industrial settings.
We demonstrate DL can be successfully applied to low interpretative tasks by embedding ECG detection and delineation onto a segmentation framework.
The model was trained using PhysioNet's QT database, comprised of 105 ambulatory ECG recordings.
arXiv Detail & Related papers (2020-05-11T16:29:12Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.