Attention-ResUNet for Automated Fetal Head Segmentation
- URL: http://arxiv.org/abs/2604.18148v1
- Date: Mon, 20 Apr 2026 12:11:21 GMT
- Title: Attention-ResUNet for Automated Fetal Head Segmentation
- Abstract summary: Attention-ResUNet is a novel architecture that combines residual learning with multi-scale attention mechanisms.<n>Our approach integrates attention gates at four decoder levels to focus selectively on anatomically relevant regions while suppressing the background noise.<n>It significantly outperforms five baseline architectures including ResUNet (99.26%), Attention U-Net (98.79%), Swin U-Net (98.60%), Standard U-Net (98.58%), and U-Net++ (97.46%)
- Score: 22.643964229988267
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Automated fetal head segmentation in ultrasound images is critical for accurate biometric measurements in prenatal care. While existing deep learning approaches have achieved a reasonable performance, they struggle with issues like low contrast, noise, and complex anatomical boundaries which are inherent to ultrasound imaging. This paper presents Attention-ResUNet. It is a novel architecture that synergistically combines residual learning with multi-scale attention mechanisms in order to achieve enhanced fetal head segmentation. Our approach integrates attention gates at four decoder levels to focus selectively on anatomically relevant regions while suppressing the background noise, and complemented by residual connections which facilitates gradient flow and feature reuse. Extensive evaluation on the HC18 Challenge dataset where n = 200 demonstrates that Attention ResUNet achieves a superior performance with a mean Dice score of 99.30 +/- 0.14% against similar architectures. It significantly outperforms five baseline architectures including ResUNet (99.26%), Attention U-Net (98.79%), Swin U-Net (98.60%), Standard U-Net (98.58%), and U-Net++ (97.46%). Through statistical analysis we confirm highly significant improvements (p < 0.001) with effect sizes that range from 0.230 to 13.159 (Cohen's d). Using Saliency map analysis, we reveal that our architecture produces highly concentrated, anatomically consistent activation patterns, which demonstrate an enhanced interpretability which is crucial for clinical deployment. The proposed method establishes a new state of the art performance for automated fetal head segmentation whilst maintaining computational efficiency with 14.7M parameters and a 45 GFLOPs inference cost. Code repository: https://github.com/Ammar-ss
Related papers
- Adapting Foundation Models for Annotation-Efficient Adnexal Mass Segmentation in Cine Images [4.42778347374376]
Adnexal mass evaluation via ultrasound is a challenging clinical task, often hindered by subjective interpretation and significant inter-observer variability.<n>We propose a label-efficient segmentation framework that leverages the robust semantic priors of a pretrained DINOv3 foundational vision transformer backbone.<n>Our method achieves state-of-the-art performance compared to established fully supervised baselines, including U-Net, U-Net++, DeepLabV3, and MAnet.
arXiv Detail & Related papers (2026-04-09T09:48:50Z) - Automated Classification of First-Trimester Fetal Heart Views Using Ultrasound-Specific Self-Supervised Learning [0.205246094017924]
We evaluate a self-supervised ultrasound foundation model, USF-MAE, for first-trimester fetal heart view classification.<n> USF-MAE is pretrained using masked autoencoding modelling on more than 370,000 unlabelled ultrasound images.<n>It achieved the highest performance across all evaluation metrics, with 90.57% accuracy, 91.15% precision, 90.57% recall, and 90.71% F1-score.
arXiv Detail & Related papers (2025-12-30T22:24:26Z) - Diagnostic Performance of Universal-Learning Ultrasound AI Across Multiple Organs and Tasks: the UUSIC25 Challenge [34.86849736082012]
Current ultrasound AI remains fragmented into single-task tools.<n>General-purpose AI models achieve high accuracy and efficiency across multiple tasks using a single architecture.
arXiv Detail & Related papers (2025-12-19T06:54:30Z) - Cancer-Net PCa-MultiSeg: Multimodal Enhancement of Prostate Cancer Lesion Segmentation Using Synthetic Correlated Diffusion Imaging [55.62977326180104]
Current deep learning approaches for prostate cancer lesion segmentation achieve limited performance.<n>We investigate synthetic correlated diffusion imaging (CDI$s$) as an enhancement to standard diffusion-based protocols.<n>Our results establish validated integration pathways for CDI$s$ as a practical drop-in enhancement for PCa lesion segmentation tasks.
arXiv Detail & Related papers (2025-11-11T04:16:12Z) - Longitudinal Vestibular Schwannoma Dataset with Consensus-based Human-in-the-loop Annotations [3.1898695141875772]
This dataset includes 190 patients, with tumour annotations available for 534 longitudinal contrast-enhanced T1-weighted (T1CE) scans from 184 patients, and non-annotated T2-weighted scans from 6 patients.<n>We show that our approach enables effective and resource-efficient generalisation of automated segmentation models to a target data distribution.<n>It is estimated to enhance efficiency by approximately 37.4% compared to the conventional manual annotation process.
arXiv Detail & Related papers (2025-11-01T09:53:28Z) - Towards the Automatic Segmentation, Modeling and Meshing of the Aortic Vessel Tree from Multicenter Acquisitions: An Overview of the SEG.A. 2023 Segmentation of the Aorta Challenge [44.01488489205175]
We introduce the SEG.A. challenge to catalyze progress in this field.<n>The challenge benchmarked automated algorithms on a hidden test set.<n>A key result was that an ensemble of the highest-ranking algorithms significantly outperformed individual models.
arXiv Detail & Related papers (2025-10-28T02:33:45Z) - Efficient Feature Extraction Using Light-Weight CNN Attention-Based Deep Learning Architectures for Ultrasound Fetal Plane Classification [3.998431476275487]
We propose a lightweight artificial intelligence architecture to classify the largest benchmark ultrasound dataset.
The approach fine-tunes from lightweight EfficientNet feature extraction backbones pre-trained on the ImageNet1k.
Our methodology incorporates the attention mechanism to refine features and 3-layer perceptrons for classification, achieving superior performance with the highest Top-1 accuracy of 96.25%, Top-2 accuracy of 99.80% and F1-Score of 0.9576.
arXiv Detail & Related papers (2024-10-22T20:02:38Z) - An Approach Towards Physics Informed Lung Ultrasound Image Scoring
Neural Network for Diagnostic Assistance in COVID-19 [0.0]
A novel approach is presented to extract acoustic propagation-based features to highlight the region below pleura in lung ultrasound (LUS)
A neural network, referred to as LUSNet, is trained to classify the LUS images into five classes of varying severity of lung infection to track the progression of COVID-19.
A detailed analysis of the proposed approach on LUS images over the infection to full recovery period of ten confirmed COVID-19 subjects shows an average five-fold cross-validation accuracy, sensitivity, and specificity of 97%, 93%, and 98% respectively over 5000 frames of COVID-19 videos.
arXiv Detail & Related papers (2021-06-13T13:01:53Z) - Hybrid Attention for Automatic Segmentation of Whole Fetal Head in
Prenatal Ultrasound Volumes [52.53375964591765]
We propose the first fully-automated solution to segment the whole fetal head in US volumes.
The segmentation task is firstly formulated as an end-to-end volumetric mapping under an encoder-decoder deep architecture.
We then combine the segmentor with a proposed hybrid attention scheme (HAS) to select discriminative features and suppress the non-informative volumetric features.
arXiv Detail & Related papers (2020-04-28T14:43:05Z) - A Global Benchmark of Algorithms for Segmenting Late Gadolinium-Enhanced
Cardiac Magnetic Resonance Imaging [90.29017019187282]
" 2018 Left Atrium Challenge" using 154 3D LGE-MRIs, currently the world's largest cardiac LGE-MRI dataset.
Analyse of the submitted algorithms using technical and biological metrics was performed.
Results show the top method achieved a dice score of 93.2% and a mean surface to a surface distance of 0.7 mm.
arXiv Detail & Related papers (2020-04-26T08:49:17Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.