PET-Adapter: Test-Time Domain Adaptation for Full and Limited-Angle PET Image Reconstruction
- URL: http://arxiv.org/abs/2605.08030v1
- Date: Fri, 08 May 2026 17:15:33 GMT
- Title: PET-Adapter: Test-Time Domain Adaptation for Full and Limited-Angle PET Image Reconstruction
- Abstract summary: We propose PET-Adapter, a test-time domain adaptation framework for generative PET reconstruction models pretrained solely on phantom data.<n>Our method enables adaptation to clinical datasets with varying anatomies, tracers, and scanner configurations without requiring paired ground truth.<n>Experiments across multiple clinical datasets demonstrate superior 3D reconstruction performance in both full-angle and limited-angle settings.
- Score: 3.0104188217541563
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods demonstrate promising performance, their generalization to unseen clinical data distributions remains limited without extensive retraining. We propose PET-Adapter, a test-time domain adaptation framework for generative PET reconstruction models pretrained solely on phantom data. Our method enables adaptation to clinical datasets with varying anatomies, tracers, and scanner configurations without requiring paired ground truth. PET-Adapter introduces layer-wise low-rank anatomical conditioning during adaptation and Ordered Subset Expectation Maximization-based warm-starting that initializes the generation from physics-informed reconstructions, reducing diffusion steps from 50 to 2 without compromising quality. Experiments across multiple clinical datasets demonstrate superior 3D reconstruction performance in both full-angle and limited-angle settings, highlighting the clinical feasibility and computational efficiency of the proposed approach.
Related papers
- PETA:Parameter-Efficient Test-Time Adaptation for Virtual Screening [49.976632553053285]
We propose PETA, a parameter-efficient framework that directly adapts pretrained model at test time.<n>PETA constructs pocket-specific negatives through molecular diffusion and chemical validity filtering.<n>A ranking objective places greater emphasis on suppressing high-scoring invalid candidates that could contaminate the top-ranked screening results.
arXiv Detail & Related papers (2026-08-20T11:17:27Z) - CT-Conditioned Diffusion Prior with Physics-Constrained Sampling for PET Super-Resolution [25.790321547743066]
We formulate PET super-resolution as posterior inference under heterogeneous system configurations.<n>We propose a CT-conditioned diffusion framework with physics-constrained sampling.<n>Under both standard and OOD settings, the proposed method consistently improves experimental metrics and lesion-level clinical relevance indicators.
arXiv Detail & Related papers (2026-03-14T11:28:23Z) - Accelerating 3D Photoacoustic Computed Tomography with End-to-End Physics-Aware Neural Operators [74.65171736966131]
Photoacoustic computed tomography (PACT) combines optical contrast with ultrasonic resolution, achieving deep-tissue imaging beyond the optical diffusion limit.<n>Current implementations require dense transducer arrays and prolonged acquisition times, limiting clinical translation.<n>We introduce Pano, an end-to-end physics-aware model that directly learns the inverse acoustic mapping from sensor measurements to volumetric reconstructions.
arXiv Detail & Related papers (2025-09-11T23:12:55Z) - Physics-Constrained Diffusion Reconstruction with Posterior Correction for Quantitative and Fast PET Imaging [17.255010452905502]
Conditional diffusion model with posterior physical correction (PET-DPC) for PET image reconstruction.<n>PET-DPC produced reconstructions closely aligned with fully corrected OSEM images, outperforming end-to-end deep learning models in quantitative metrics.
arXiv Detail & Related papers (2025-08-20T02:39:55Z) - PET Image Reconstruction Using Deep Diffusion Image Prior [3.1878756384085936]
We propose an anatomical prior-guided PET image reconstruction method based on diffusion models.<n>The proposed method alternated between diffusion sampling and model fine-tuning guided by the PET sinogram.<n>Experiment results show that the proposed PET reconstruction method can generalize robustly across tracer distributions and scanner types.
arXiv Detail & Related papers (2025-07-20T18:25:29Z) - Supervised Diffusion-Model-Based PET Image Reconstruction [44.89560992517543]
Diffusion models (DMs) have been introduced as a regularizing prior for PET image reconstruction.<n>We propose a supervised DM-based algorithm for PET reconstruction.<n>Our method enforces the non-negativity of PET's Poisson likelihood model and accommodates the wide intensity range of PET images.
arXiv Detail & Related papers (2025-06-30T16:39:50Z) - Personalized MR-Informed Diffusion Models for 3D PET Image Reconstruction [40.722159771726375]
We propose a simple method for generating subject-specific PET images from a dataset of PET-MR scans.<n>The images we synthesize retain information from the subject's MR scan, leading to higher resolution and the retention of anatomical features.<n>With simulated and real [$18$F]FDG datasets, we show that pre-training a personalized diffusion model with subject-specific "pseudo-PET" images improves reconstruction accuracy with low-count data.
arXiv Detail & Related papers (2025-06-04T10:24:14Z) - Synthetic CT Generation from Time-of-Flight Non-Attenutaion-Corrected PET for Whole-Body PET Attenuation Correction [6.062988223565465]
This study presents a deep learning approach to generate synthetic CT (sCT) images directly from Time-of-Flight non-attenuation corrected (NAC) PET images.<n>We first evaluated models pre-trained on large-scale natural image datasets for a CT-to-CT reconstruction task.<n>Visual assessments demonstrated improved reconstruction of both bone and soft tissue structures from TOF NAC PET images.
arXiv Detail & Related papers (2025-04-10T04:49:41Z) - Two-stage deep learning framework for the restoration of incomplete-ring PET images [0.6478690173421426]
We present a two-stage deep-learning framework that restores high-quality images from data with about 50% missing coincidences.<n>We also achieve higher inference speed, thus providing an effective solution for incomplete-ring PET imaging.
arXiv Detail & Related papers (2025-04-01T14:05:32Z) - HiDe-PET: Continual Learning via Hierarchical Decomposition of Parameter-Efficient Tuning [55.88910947643436]
We propose a unified framework for continual learning (CL) with pre-trained models (PTMs) and parameter-efficient tuning (PET)<n>We present Hierarchical Decomposition PET (HiDe-PET), an innovative approach that explicitly optimize the objective through incorporating task-specific and task-shared knowledge.<n>Our approach demonstrates remarkably superior performance over a broad spectrum of recent strong baselines.
arXiv Detail & Related papers (2024-07-07T01:50:25Z) - Diffusion Transformer Model With Compact Prior for Low-dose PET Reconstruction [7.320877150436869]
We propose a diffusion transformer model (DTM) guided by joint compact prior (JCP) to enhance the reconstruction quality of low-dose PET imaging.
DTM combines the powerful distribution mapping abilities of diffusion models with the capacity of transformers to capture long-range dependencies.
Our approach not only reduces radiation exposure risks but also provides a more reliable PET imaging tool for early disease detection and patient management.
arXiv Detail & Related papers (2024-07-01T03:54:43Z) - Image2Points:A 3D Point-based Context Clusters GAN for High-Quality PET
Image Reconstruction [47.398304117228584]
We propose a 3D point-based context clusters GAN, namely PCC-GAN, to reconstruct high-quality SPET images from LPET.
Experiments on both clinical and phantom datasets demonstrate that our PCC-GAN outperforms the state-of-the-art reconstruction methods.
arXiv Detail & Related papers (2024-02-01T06:47:56Z) - Contrastive Diffusion Model with Auxiliary Guidance for Coarse-to-Fine
PET Reconstruction [62.29541106695824]
This paper presents a coarse-to-fine PET reconstruction framework that consists of a coarse prediction module (CPM) and an iterative refinement module (IRM)
By delegating most of the computational overhead to the CPM, the overall sampling speed of our method can be significantly improved.
Two additional strategies, i.e., an auxiliary guidance strategy and a contrastive diffusion strategy, are proposed and integrated into the reconstruction process.
arXiv Detail & Related papers (2023-08-20T04:10:36Z) - A Unified Continual Learning Framework with General Parameter-Efficient
Tuning [56.250772378174446]
"Pre-training $rightarrow$ downstream adaptation" presents both new opportunities and challenges for Continual Learning.
We position prompting as one instantiation of PET, and propose a unified CL framework, dubbed as Learning-Accumulation-Ensemble (LAE)
PET, e.g., using Adapter, LoRA, or Prefix, can adapt a pre-trained model to downstream tasks with fewer parameters and resources.
arXiv Detail & Related papers (2023-03-17T15:52:45Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.