Exploiting ionization dynamics in the nitrogen vacancy center for rapid, high-contrast spin and charge state initialization
- URL: http://arxiv.org/abs/2605.13480v1
- Date: Wed, 13 May 2026 13:05:57 GMT
- Title: Exploiting ionization dynamics in the nitrogen vacancy center for rapid, high-contrast spin and charge state initialization
- Abstract summary: We propose and experimentally demonstrate a method to strongly increase the sensitivity of spin measurements on nitrogen-vacancy (NV) centers in diamond.<n>We show here that these can be used to significantly increase the NV center's spin contrast, a key quantity for high sensitivity magnetometry and high fidelity state readout.<n>Our findings give detailed insight into the charge and spin polarization dynamics of the NV center, and provide actionable insights for direct optical, spin-to-charge, and electrical readout of solid-state spin centres.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: We propose and experimentally demonstrate a method to strongly increase the sensitivity of spin measurements on nitrogen-vacancy (NV) centers in diamond, which can be readily implemented in existing quantum sensing experiments. While charge state transitions of this defect are generally considered a parasitic effect to be avoided, we show here that these can be used to significantly increase the NV center's spin contrast, a key quantity for high sensitivity magnetometry and high fidelity state readout. The protocol consists of a two-step procedure, in which the charge state of the defect is first purified by a strong laser pulse, followed by weak illumination to obtain high spin polarization. We observe a relative improvement of the readout contrast by 17 %, and infer a reduction of the initialization error of more than 50 %. The contrast enhancement is accompanied by a beneficial increase of the readout signal. For long sequence durations, typically encountered in high-resolution magnetometry, a measurement speedup by a factor of >1.5 is extracted, and we find that the technique is beneficial for sequences of any duration. Additionally, our findings give detailed insight into the charge and spin polarization dynamics of the NV center, and provide actionable insights for direct optical, spin-to-charge, and electrical readout of solid-state spin centres.
Related papers
- Dispersive readout of cavity-coupled solid-state sensor with near-unity readout fidelity [4.936475003630715]
We introduce a dispersive cQED readout technique to overcome fundamental limitations in NV ensemble sensing.<n>Results indicate near-unity inverse readout fidelity and femtotesla-level sensitivity using a commercially available diamond NV ensemble.
arXiv Detail & Related papers (2026-05-24T16:15:37Z) - Photoswitchable radicals as reporter spins for quantum sensing with spin defects in diamond [0.0]
rapid decay of target signal strength with distance from the sensor presents a key challenge in nanoscale magnetic sensing.<n>We introduce a strategy to overcome this limitation by using radical anions formed from rhodamine-derived dyes as reporter spins localized to the diamond surface.<n>We experimentally demonstrate their coherent manipulation and detection using single, shallow NV centers for readout.
arXiv Detail & Related papers (2025-10-06T21:55:05Z) - Intermediate Excited State Relaxation Dynamics of Boron-Vacancy Spin Defects in Hexagonal Boron Nitride [0.0]
We investigate the dynamics of the excited and intermediate states in the optical cycle under pulsed laser excitation in a broad temperature range.<n>Experiments show a relaxation time of 24 ns from the metastable state back to the ground state at room temperature.<n>We optimize pulsed optically detected magnetic resonance sequences to account for the relaxation of the intermediate state.
arXiv Detail & Related papers (2025-03-28T18:23:07Z) - First Sub-MeV Dark Matter Search with the QROCODILE Experiment Using Superconducting Nanowire Single-Photon Detectors [51.550188330599525]
We present the first results from the Quantum Resolution-d Cryogenic Observatory for Dark matter Incident at Low Energy (QROCODILE)<n>The QROCODILE experiment uses a microwire-based superconducting nanowire single-photon detector (SNSPD) as a target and sensor for dark matter scattering and absorption.<n>We report new world-leading constraints on the interactions of sub-MeV dark matter particles with masses as low as 30 keV.
arXiv Detail & Related papers (2024-12-20T19:00:00Z) - Resonant versus non-resonant spin readout of a nitrogen-vacancy center
in diamond under cryogenic conditions [0.0]
We examine the impact of spin-selective, narrow-band laser excitation on nitrogen-vacancy readout.
We demonstrate a more than four-fold improvement in sensitivity compared to that possible with non-resonant illumination.
These results open opportunities in the application of NV sensing to the investigation of condensed matter systems.
arXiv Detail & Related papers (2023-12-05T17:27:08Z) - Control of an environmental spin defect beyond the coherence limit of a central spin [79.16635054977068]
We present a scalable approach to increase the size of electronic-spin registers.
We experimentally realize this approach to demonstrate the detection and coherent control of an unknown electronic spin outside the coherence limit of a central NV.
Our work paves the way for engineering larger quantum spin registers with the potential to advance nanoscale sensing, enable correlated noise spectroscopy for error correction, and facilitate the realization of spin-chain quantum wires for quantum communication.
arXiv Detail & Related papers (2023-06-29T17:55:16Z) - All-Optical Nuclear Quantum Sensing using Nitrogen-Vacancy Centers in
Diamond [52.77024349608834]
Microwave or radio-frequency driving poses a significant limitation for miniaturization, energy-efficiency and non-invasiveness of quantum sensors.
We overcome this limitation by demonstrating a purely optical approach to coherent quantum sensing.
Our results pave the way for highly compact quantum sensors to be employed for magnetometry or gyroscopy applications.
arXiv Detail & Related papers (2022-12-14T08:34:11Z) - Enhancement of spin-to-charge conversion of diamond NV centers at
ambient conditions using surface electrodes [0.0]
We present a new mechanism for high contrast readout using the spin-to-charge conversion mechanism.
The technique opens up a range of alternative research pathways for the nitrogen-vacancy center in diamond.
arXiv Detail & Related papers (2022-09-28T11:40:21Z) - Rapidly enhanced spin polarization injection in an optically pumped spin
ratchet [49.1301457567913]
We report on a strategy to boost the spin injection rate by exploiting electrons that can be rapidly polarized.
We demonstrate this in a model system of Nitrogen Vacancy center electrons injecting polarization into a bath of 13C nuclei in diamond.
Through a spin-ratchet polarization transfer mechanism, we show boosts in spin injection rates by over two orders of magnitude.
arXiv Detail & Related papers (2021-12-14T08:23:10Z) - Five-second coherence of a single spin with single-shot readout in
silicon carbide [84.97423065534817]
We demonstrate single-shot readout of single defects in silicon carbide (SiC)
We achieve over 80% readout fidelity without pre- or post-selection.
We report single spin T2 > 5s, over two orders of magnitude greater than previously reported in this system.
arXiv Detail & Related papers (2021-10-04T17:35:02Z) - Laser threshold magnetometry using green light absorption by diamond
nitrogen vacancies in an external cavity laser [52.77024349608834]
Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing.
We show theoretical sensitivity to magnetic field on the pT/sqrt(Hz) level is possible using a diamond with an optimal density of NV centers.
arXiv Detail & Related papers (2021-01-22T18:58:05Z) - Cavity quantum electrodynamic readout of a solid-state spin sensor [0.0]
Solid-state spin sensors still lack a universal, high-fidelity readout technique.
We demonstrate high-fidelity, room-temperature readout of an ensemble of nitrogen-vacancy (NV) centers via strong coupling to a dielectric microwave cavity.
Our results pave a clear path to achieve unity readout fidelity of solid-state spin sensors through increased ensemble size, reduced spin-resonance linewidth, or improved cavity quality factor.
arXiv Detail & Related papers (2020-03-02T18:57:40Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.