Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report
- URL: http://arxiv.org/abs/2605.13555v1
- Date: Wed, 13 May 2026 13:59:03 GMT
- Title: Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report
- Abstract summary: Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers.<n>Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability.<n>Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon.
- Score: 5.438928824496922
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE $64.8\pm21.3$ HU, PSNR $\sim$30 dB, MS-SSIM $\sim$0.936, Dice 0.79, photon $γ_{2\%/2\text{mm}}>98\%$, proton $γ\approx85\%$. Task 2 improved: MAE $48.3\pm13.4$ HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon $γ>99\%$, proton $γ\approx89\%$. Strong image--segmentation correlations ($ρ=0.78$--$0.79$) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.
Related papers
- A cross-modal generative model for incomplete and degraded prostate MRI with multicentre clinical validation [48.14053205497089]
MSCNet is a sequence-conditioned cross-modal generative framework for reconstructing unavailable contrasts and restoring degraded acquisitions.<n>Overall image quality met the prespecified non-inferiority criterion for DWI, ADC and T2W completion, but not T1W.
arXiv Detail & Related papers (2026-08-17T08:11:25Z) - Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling [51.330452704464925]
We train a latent diffusion model on 1,046 PCCTs and 405,379 EICTs from 145 hospitals.<n>We construct a large-scale dataset of over 17,316 publicly available EICTs enhanced to PCCT-like quality.<n>Our results suggest emerging imaging advances can be systematically distilled into routine EICT using limited high-quality scans as reference.
arXiv Detail & Related papers (2026-04-08T17:47:35Z) - GANeXt: A Fully ConvNeXt-Enhanced Generative Adversarial Network for MRI- and CBCT-to-CT Synthesis [4.966806084618106]
We propose GANeXt, a 3D patch-based, fully ConvNeXt-powered generative adversarial network for unified CT synthesis.<n>Specifically, GANeXt employs an efficient U-shaped generator constructed from stacked 3D ConvNeXt blocks with compact kernels.<n>To improve synthesis quality, we incorporate a combination of loss functions, including mean absolute error (MAE), perceptual loss, segmentation-based masked MAE, and adversarial loss.
arXiv Detail & Related papers (2025-12-22T12:32:16Z) - Neural Discrete Representation Learning for Sparse-View CBCT Reconstruction: From Algorithm Design to Prospective Multicenter Clinical Evaluation [64.42236775544579]
Cone beam computed tomography (CBCT)-guided puncture has become an established approach for diagnosing and treating thoracic tumours.<n>DeepPriorCBCT is a three-stage deep learning framework that achieves diagnostic-grade reconstruction using only one-sixth of the conventional radiation dose.
arXiv Detail & Related papers (2025-11-30T12:45:02Z) - EqDiff-CT: Equivariant Conditional Diffusion model for CT Image Synthesis from CBCT [43.92108185590778]
Cone-beam computed tomography (CBCT) is widely used for imageguided radiotherapy (IGRT)<n>We propose a novel diffusion-based conditional generative model, coined EqDiff-CT, to synthesize high-quality CT images from CBCT.
arXiv Detail & Related papers (2025-09-26T05:51:59Z) - Analysis of the BraTS 2023 Intracranial Meningioma Segmentation Challenge [44.76736949127792]
We describe the design and results from the BraTS 2023 Intracranial Meningioma Challenge.<n>The BraTS Meningioma Challenge differed from prior BraTS Glioma challenges in that it focused on meningiomas.<n>The top ranked team had a lesion-wise median dice similarity coefficient (DSC) of 0.976, 0.976, and 0.964 for enhancing tumor, tumor core, and whole tumor.
arXiv Detail & Related papers (2024-05-16T03:23:57Z) - Cycle-consistent Generative Adversarial Network Synthetic CT for MR-only
Adaptive Radiation Therapy on MR-Linac [0.0]
Cycle-GAN model was trained with MRI and CT scan slices from MR-LINAC treatments, generating sCT volumes.
Dosimetric evaluations indicated minimal differences between sCTs and dCTs, with sCTs showing better air-bubble reconstruction.
arXiv Detail & Related papers (2023-12-03T04:38:17Z) - Energy-Guided Diffusion Model for CBCT-to-CT Synthesis [8.888473799320593]
Cone Beam CT (CBCT) plays a crucial role in Adaptive Radiation Therapy (ART) by accurately providing radiation treatment when organ anatomy changes occur.
CBCT images suffer from scatter noise and artifacts, making relying solely on CBCT for precise dose calculation and accurate tissue localization challenging.
We propose an energy-guided diffusion model (EGDiff) and conduct experiments on a chest tumor dataset to generate synthetic CT (sCT) from CBCT.
arXiv Detail & Related papers (2023-08-07T07:23:43Z) - Synthetic CT Generation from MRI using 3D Transformer-based Denoising
Diffusion Model [2.232713445482175]
Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning.
We propose an MRI-to-CT transformer-based denoising diffusion probabilistic model (MC-DDPM) to transform MRI into high-quality sCT.
arXiv Detail & Related papers (2023-05-31T00:32:00Z) - Evaluation of Synthetically Generated CT for use in Transcranial Focused
Ultrasound Procedures [5.921808547303054]
Transcranial focused ultrasound (tFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively and often under MRI guidance.
CT imaging is used to estimate the acoustic properties that vary between individual skulls to enable effective focusing during tFUS procedures.
Here, we synthesized CT images from routinely acquired T1-weighted MRI by using a 3D patch-based conditional generative adversarial network (cGAN)
We compared the performance of sCT to real CT (rCT) images for tFUS planning using Kranion and simulations using the acoustic toolbox,
arXiv Detail & Related papers (2022-10-26T15:15:24Z) - A multicenter study on radiomic features from T$_2$-weighted images of a
customized MR pelvic phantom setting the basis for robust radiomic models in
clinics [47.187609203210705]
2D and 3D T$$-weighted images of a pelvic phantom were acquired on three scanners.
repeatability and repositioning of radiomic features were assessed.
arXiv Detail & Related papers (2020-05-14T09:24:48Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.