Personalized 3D Myocardial Infarct Geometry Reconstruction from Cine MRI for Cardiac Digital Twins
- URL: http://arxiv.org/abs/2606.01808v1
- Date: Mon, 01 Jun 2026 07:25:56 GMT
- Title: Personalized 3D Myocardial Infarct Geometry Reconstruction from Cine MRI for Cardiac Digital Twins
- Abstract summary: We propose a novel explicit geometry-motion embedded model to reconstruct 3D MI directly from cine MRIs.<n> Experimental results on 225 cine MRIs demonstrated that the proposed 3D MI reconstruction achieved high performance with an average Dice score of 0.678 $pm$ 0.011.
- Score: 7.407471411133294
- License: http://creativecommons.org/licenses/by-sa/4.0/
- Abstract: Accurate 3D geometric characterization of myocardial infarction (MI) is essential for building cardiac digital twins (CDTs) to precisely simulate infarct-related electrophysiology. Late gadolinium enhancement magnetic resonance imaging (LGE MRI) is the clinical reference for locating MI, yet its reliance on contrast agents restricts use in renally impaired patients and limits longitudinal follow-ups. As an alternative, contrast-free cine MRI visualizes abnormal ventricular wall motion, which is highly indicative of the infarcted area. In this study, we propose a novel explicit geometry-motion embedded model to fully automatically reconstruct personalized, simulation-ready 3D MI geometries directly from multi-view cine MRIs. Specifically, we construct a 4D (3D + t) biventricular mesh to explicitly extract and decouple geometry-aware and motion-aware features. We further design a dual-branch module for adaptive geometry-motion fusion to capture spatiotemporal dependencies for mapping infarcted region. Furthermore, we introduce multi-scale supervision utilizing an AHA-17 segment-guided cross-attention mechanism to steer the prediction, ensuring biophysically consistent reconstruction. Experimental results on 225 cine MRIs demonstrated that the proposed 3D MI reconstruction achieved high performance with an average Dice score of 0.678 $\pm$ 0.011. In the downstream in-silico electrophysiological simulation evaluations, the results were highly consistent with the LGE-derived ground truth, highlighting the great potential of the proposed model for contrast-free scar characterization and seamless integration into CDT modeling. The code will be released publicly upon acceptance of the manuscript for publication.
Related papers
- Personalized 4D Whole-Heart Mesh Reconstruction from Cine MRI via Multi-Scale Temporal Modeling and Differentiable Contour Rendering [7.111748961723236]
We propose a novel end-to-end framework for reconstructing temporally resolved whole-heart meshes from 2D cine MRI sequences.<n>The framework incorporates a differentiable contour inspired by the Beer-Lambert attenuation principle, enabling anatomy-aware supervision of 3D+t mesh deformation.<n>The proposed method achieved a whole-heart mean absolute error of 1.68 $pm$ 0.31 mm and a motion jitter of 0.77 $pm$ 0.17 $mathrmmm/mathrmframe3$, outperforming existing methods with lower reconstruction error and substantially improved motion smoothness.
arXiv Detail & Related papers (2026-07-02T09:42:46Z) - Rendering Novel Views of MRI Using 3D Gaussian Splatting [54.6286495315908]
We adapt 3D Gaussian Splatting to form a reconstruction starting from sparse anisotropic MRIs, and imaging planes aligned with the anatomy relevant for clinical evaluation are then sampled and rendered.<n>The novel view plane is optimal for diagnostic radiological grading of the target anatomy, whereas the original MRI is not.
arXiv Detail & Related papers (2026-06-24T18:00:03Z) - 3D Conditional Image Synthesis of Left Atrial LGE MRI from Composite Semantic Masks [1.452875650827562]
We develop a pipeline to synthesize high-fidelity 3D LGE MRI volumes using 3D conditional generators.<n> SPADE-LDM generates the most realistic and structurally accurate images.<n>When augmented with synthetic LGE images, the Dice score for LA cavity segmentation with a 3D U-Net model improved.
arXiv Detail & Related papers (2026-01-08T04:35:40Z) - Personalized 3D Myocardial Infarct Geometry Reconstruction from Cine MRI with Explicit Cardiac Motion Modeling [7.573784171306414]
We propose a novel framework for automatically reconstructing high-fidelity 3D myocardial infarct geometry from 2D clinically standard cine MRIs.<n>Specifically, we first reconstruct the 4D biventricular mesh from multi-view cine MRIs via an automatic deep shape fitting model, biv-me.<n>Then, we design a infarction reconstruction model, CMotion2Infarct-Net, to explicitly utilize the motion patterns within this dynamic geometry to localize infarct regions.
arXiv Detail & Related papers (2025-07-21T02:43:35Z) - JSover: Joint Spectrum Estimation and Multi-Material Decomposition from Single-Energy CT Projections [45.14515691206885]
Multi-material decomposition (MMD) enables quantitative reconstruction of tissue compositions in the human body.<n>Traditional MMD typically requires spectral CT scanners and pre-measured X-ray energy spectra, significantly limiting clinical applicability.<n>This paper proposes JSover, a fundamentally reformulated one-step SEMMD framework that jointly reconstructs multi-material compositions and estimates the energy spectrum directly from SECT projections.
arXiv Detail & Related papers (2025-05-12T23:32:21Z) - Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI [43.47826598981827]
We introduce HybridVNet, a novel architecture for direct image-to-mesh extraction.<n>We show it can efficiently handle surface and volumetric meshes by encoding them as graph structures.<n>Our model combines traditional convolutional networks with variational graph generative models, deep supervision and mesh-specific regularisation.
arXiv Detail & Related papers (2023-11-22T21:51:29Z) - Volumetric Reconstruction Resolves Off-Resonance Artifacts in Static and
Dynamic PROPELLER MRI [76.60362295758596]
Off-resonance artifacts in magnetic resonance imaging (MRI) are visual distortions that occur when the actual resonant frequencies of spins within the imaging volume differ from the expected frequencies used to encode spatial information.
We propose to resolve these artifacts by lifting the 2D MRI reconstruction problem to 3D, introducing an additional "spectral" dimension to model this off-resonance.
arXiv Detail & Related papers (2023-11-22T05:44:51Z) - Multi-class point cloud completion networks for 3D cardiac anatomy
reconstruction from cine magnetic resonance images [4.1448595037512925]
We propose a novel fully automatic surface reconstruction pipeline capable of reconstructing multi-class 3D cardiac anatomy meshes.
Its key component is a multi-class point cloud completion network (PCCN) capable of correcting both the sparsity and misalignment issues of the 3D reconstruction task.
arXiv Detail & Related papers (2023-07-17T14:52:52Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z) - Enhanced 3D Myocardial Strain Estimation from Multi-View 2D CMR Imaging [0.0]
We propose an enhanced 3D myocardial strain estimation procedure, which combines complementary displacement information from multiple orientations of a single imaging modality (untagged CMR SSFP images)
We register the sets of short-axis, four-chamber and two-chamber views via a 2D non-rigid registration algorithm implemented in a commercial software (Segment, Medviso)
We then create a series of interpolating functions for the three directions of motion and use them to deform a tetrahedral mesh representation of a patient-specific left ventricle.
arXiv Detail & Related papers (2020-09-25T22:47:50Z) - Segmentation of the Myocardium on Late-Gadolinium Enhanced MRI based on
2.5 D Residual Squeeze and Excitation Deep Learning Model [55.09533240649176]
The aim of this work is to develop an accurate automatic segmentation method based on deep learning models for the myocardial borders on LGE-MRI.
A total number of 320 exams (with a mean number of 6 slices per exam) were used for training and 28 exams used for testing.
The performance analysis of the proposed ensemble model in the basal and middle slices was similar as compared to intra-observer study and slightly lower at apical slices.
arXiv Detail & Related papers (2020-05-27T20:44:38Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.