Efficient Transformer-Based Localized Patch Sampling for Choroid Plexus Segmentation in Multiple Sclerosis
- URL: http://arxiv.org/abs/2606.03566v1
- Date: Tue, 02 Jun 2026 12:32:43 GMT
- Title: Efficient Transformer-Based Localized Patch Sampling for Choroid Plexus Segmentation in Multiple Sclerosis
- Abstract summary: The lateral ventricle choroid plexus (LVCP) is gaining recognition as a key imaging biomarker for multiple sclerosis (MS) related to physical disability and neuroinflammation.<n>This research aims to develop a SwinUNETR-driven pipeline that automatically segment the LVCP in MS from both standalone and multi-modal MRI inputs.
- Score: 26.831715552066694
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Background: The lateral ventricle choroid plexus (LVCP) is gaining recognition as a key imaging biomarker for multiple sclerosis (MS) related to physical disability and neuroinflammation. Yet, manual segmentation of the LVCP is highly tedious, restricting its use in broad clinical trials and longitudinal assessments. This research aims to develop a SwinUNETR-driven pipeline that leverages targeted intra- and peri-ventricular small patch sampling to automatically segment the LVCP in MS from both standalone and multi-modal MRI inputs. Methods: We retrospectively assessed 3T MRI scans across three sets of data stemming from two separate MS-dominant cohorts (Dataset 1: n=177; Dataset 2: n=177; expanded test set: n=388). Our method employed a SwinUNETR architecture trained on 32x32x32 voxel patches, benchmarking it against the 3D UXNET model. The primary metric for evaluation was the Dice Similarity Coefficient (DSC), supplemented by computational demand (GFLOPs) and the 95th percentile Hausdorff Distance (HD95). Results: On the extended test set, the SwinUNETR model secured a mean DSC of 0.868 (95% CI: 0.863-0.872) with MPRAGE and FLAIR combined, showing a statistically significant gain over UXNET (DSC: 0.858 [95% CI: 0.853-0.862], p<0.0001). When restricted to standalone FLAIR inputs, the transformer-based approach sustained a high DSC of 0.863, while the spatial localization of UXNET worsened considerably (HD95: 1.86 vs. 3.00 mm). Importantly, the proposed framework lowered computational load by 99% (91.8 vs. 22,080 GFLOPs). By integrating localized patch sampling with a SwinUNETR architecture, this methodology offers an accurate, robust, and statistically superior alternative to current leading models for LVCP segmentation. Its vast reduction in computational cost makes it ideal for widespread implementation in clinical and research environments.
Related papers
- A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery [5.486895610501164]
Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.<n>We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context.<n>A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy.
arXiv Detail & Related papers (2026-08-12T17:13:59Z) - Post-Operative Glioma Segmentation via Loss Stabilization, Normalization and Subspace Attention [46.03321798937855]
We show that the standard Generalized Dice Loss (GDL) is unstable under domain shift.<n>We propose a Subspace-Aware Class Attention (SACA) module that re-calibrates the bottleneck features and raises Enhancing Tumor (ET) sensitivity by 8%.
arXiv Detail & Related papers (2026-07-23T09:59:30Z) - Beyond Anatomy: Explainable ASD Classification from rs-fMRI via Functional Parcellation and Graph Attention Networks [6.923757075165361]
Anatomical brain parcellations dominate rs-fMRI-based Autism Spectrum Disorder (ASD) classification.<n>We present a graph-based deep learning framework comparing anatomical (AAL) and functionally-derived (MSDL) parcellation strategies on the ABIDE I dataset.
arXiv Detail & Related papers (2026-03-03T02:05:20Z) - Fluence Map Prediction with Deep Learning: A Transformer-based Approach [4.362977319915193]
This study presents a deep learning framework that accelerates fluence map generation while maintaining clinical quality.<n>An end-to-end 3D Swin-UNETR network was trained to predict nine-beam fluence maps directly from volumetric CT images and anatomical contours.<n>The proposed model achieved an average R2 of 0.95 +/- 0.02, MAE of 0.035 +/- 0.008, and gamma passing rate of 85 +/- 10 percent (3 percent / 3 mm) on the test set.
arXiv Detail & Related papers (2025-11-10T19:24:14Z) - A Novel Attention-Augmented Wavelet YOLO System for Real-time Brain Vessel Segmentation on Transcranial Color-coded Doppler [49.03919553747297]
We propose an AI-powered, real-time CoW auto-segmentation system capable of efficiently capturing cerebral arteries.<n>No prior studies have explored AI-driven cerebrovascular segmentation using Transcranial Color-coded Doppler (TCCD)<n>The proposed AAW-YOLO demonstrated strong performance in segmenting both ipsilateral and contralateral CoW vessels.
arXiv Detail & Related papers (2025-08-19T14:41:22Z) - Explainable Anatomy-Guided AI for Prostate MRI: Foundation Models and In Silico Clinical Trials for Virtual Biopsy-based Risk Assessment [3.5408411348831232]
We present a fully automated, anatomically guided deep learning pipeline for prostate cancer (PCa) risk stratification using routine MRI.<n>The pipeline integrates three key components: an nnU-Net module for segmenting the prostate gland and its zones on axial T2-weighted MRI; a classification module based on the DiceedPT Swin Transformer foundation model, fine-tuned on 3D patches with optional anatomical priors and clinical data; and a VAE-GAN framework for generating counterfactual heatmaps that localize decision-driving image regions.
arXiv Detail & Related papers (2025-05-23T14:40:09Z) - A weakly-supervised deep learning model for fast localisation and delineation of the skeleton, internal organs, and spinal canal on Whole-Body Diffusion-Weighted MRI (WB-DWI) [0.0]
We developed an automated deep-learning pipeline based on a 3D patch-based Residual U-Net architecture.<n>We employed a multi-centre WB-DWI dataset comprising 532 scans from patients with Advanced Prostate Cancer (APC) or Multiple Myeloma (MM)<n>Relative median ADC differences between automated and manual full-body delineations were below 10%.<n>The model was 12x faster than the atlas-based registration algorithm.
arXiv Detail & Related papers (2025-03-26T17:03:46Z) - CIMIL-CRC: a clinically-informed multiple instance learning framework for patient-level colorectal cancer molecular subtypes classification from H\&E stained images [42.771819949806655]
We introduce CIMIL-CRC', a framework that solves the MSI/MSS MIL problem by efficiently combining a pre-trained feature extraction model with principal component analysis (PCA) to aggregate information from all patches.
We assessed our CIMIL-CRC method using the average area under the curve (AUC) from a 5-fold cross-validation experimental setup for model development on the TCGA-CRC-DX cohort.
arXiv Detail & Related papers (2024-01-29T12:56:11Z) - Weakly supervised segmentation of intracranial aneurysms using a novel 3D focal modulation UNet [0.5106162890866905]
We propose FocalSegNet, a novel 3D focal modulation UNet, to detect an aneurysm and offer an initial, coarse segmentation of it from time-of-flight MRA image patches.
We trained and evaluated our model on a public dataset, and in terms of UIA detection, our model showed a low false-positive rate of 0.21 and a high sensitivity of 0.80.
arXiv Detail & Related papers (2023-08-06T03:28:08Z) - Attention-based Saliency Maps Improve Interpretability of Pneumothorax
Classification [52.77024349608834]
To investigate chest radiograph (CXR) classification performance of vision transformers (ViT) and interpretability of attention-based saliency.
ViTs were fine-tuned for lung disease classification using four public data sets: CheXpert, Chest X-Ray 14, MIMIC CXR, and VinBigData.
ViTs had comparable CXR classification AUCs compared with state-of-the-art CNNs.
arXiv Detail & Related papers (2023-03-03T12:05:41Z) - COVID-MTL: Multitask Learning with Shift3D and Random-weighted Loss for
Automated Diagnosis and Severity Assessment of COVID-19 [39.57518533765393]
There is an urgent need for automated methods to assist accurate and effective assessment of COVID-19.
We present an end-to-end multitask learning framework (COVID-MTL) that is capable of automated and simultaneous detection (against both radiology and NAT) and severity assessment of COVID-19.
arXiv Detail & Related papers (2020-12-10T08:30:46Z) - CovidDeep: SARS-CoV-2/COVID-19 Test Based on Wearable Medical Sensors
and Efficient Neural Networks [51.589769497681175]
The novel coronavirus (SARS-CoV-2) has led to a pandemic.
The current testing regime based on Reverse Transcription-Polymerase Chain Reaction for SARS-CoV-2 has been unable to keep up with testing demands.
We propose a framework called CovidDeep that combines efficient DNNs with commercially available WMSs for pervasive testing of the virus.
arXiv Detail & Related papers (2020-07-20T21:47:28Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.