A Lightweight Fiducial-Based Pipeline for 3D Hyperspectral Mapping of ex-vivo Lumpectomy Specimens
- URL: http://arxiv.org/abs/2606.14534v1
- Date: Fri, 12 Jun 2026 15:11:50 GMT
- Title: A Lightweight Fiducial-Based Pipeline for 3D Hyperspectral Mapping of ex-vivo Lumpectomy Specimens
- Abstract summary: We present a fully automated, calibration-free pipeline that produces a 3D hyperspectral point cloud of an ex-vivo lumpectomy specimen.<n>The pipeline achieves a median 3D registration error below 1mm and a 2D reprojection error below 0.02 mm, with a total per-specimen processing time under 4 minutes on accelerated hardware.
- Score: 5.019796206315394
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Hyperspectral Imaging (HSI) is a promising modality for intraoperative assessment of resection margins in Breast-Conserving Surgery (BCS), but its clinical translation requires aligning the inherently 2D spectral information onto the 3D shape of the excised tissue so that suspicious regions can be precisely localized for targeted follow-up. We present a fully automated, calibration-free pipeline that produces a 3D hyperspectral point cloud of an ex-vivo lumpectomy specimen from a set of consumer-camera RGB images and a single top-down HSI acquisition. The 3D geometry is reconstructed with a deep-learning Structure-from-Motion backbone, stabilized in a metric reference frame by a custom bundle adjustment that enforces consistency on the corners of four ArUco markers placed around the specimen. The HSI cube is then registered to the reconstruction without recovering the HSI camera pose: the markers, visible in both modalities, define 16 corner correspondences that drive a planar homography, and 3D coordinates are recovered by lookup on an orthographically rendered depth map. Evaluated on two ex-vivo lumpectomy specimens, the pipeline achieves a median 3D registration error below 1~mm and a 2D reprojection error below 0.02 mm, with a total per-specimen processing time under 4 minutes on accelerated hardware. These results support the feasibility of integrating HSI-guided spatial localization into intraoperative margin assessment workflows for breast-conserving surgery.
Related papers
- Toward surface-based registration of a virtual preoperative cutting guide onto the mandible for reconstruction surgery [8.636647142945273]
Patient-specific cutting guides transfer a computed tomography (CT)-based plan to the operating room.<n> printed guides add cost and lead time, cannot adapt after fabrication, and may interrupt surgery if sterility is lost.<n>We investigate a markerless augmented reality (AR) alternative that registers a virtual cutting guide to the exposed mandible from surface geometry.
arXiv Detail & Related papers (2026-08-06T21:15:59Z) - Echo-POSED: Geometric Self-Distillation for Echocardiography Guidance [0.7588863588485085]
We introduce Echo-POSED, a self-supervised framework for real-time transthoracic echocardiography (TTE) guidance.<n>It recommends probe adjustments directly from 2D ultrasound images, without the need for expert-labelled views or tracked probe trajectories.
arXiv Detail & Related papers (2026-05-30T20:37:43Z) - Preoperative-to-intraoperative Liver Registration for Laparoscopic Surgery via Latent-Grounded Correspondence Constraints [51.7011449975586]
Land-Reg is a deformable registration framework that learns latent-grounded 2D-3D landmark correspondences.<n>For rigid registration, Land-Reg embraces a Cross-modal Latent Alignment module.<n>An Uncertainty-enhanced Overlap Landmark Detector with similarity matching is proposed to robustly estimate explicit 2D-3D landmark correspondences.
arXiv Detail & Related papers (2026-03-02T10:44:03Z) - Diff2DGS: Reliable Reconstruction of Occluded Surgical Scenes via 2D Gaussian Splatting [10.70948053935438]
We propose Diff2DGS, a novel two-stage framework for reliable 3D reconstruction of occluded surgical scenes.<n>In the first stage, a diffusion-based video module with temporal priors inpaints tissue occluded by instruments with high spatial-temporal consistency.<n>In the second stage, we adapt 2D Gaussian Splatting (2DGS) with a Learnable Deformation Model (LDM) to capture dynamic tissue deformation and anatomical geometry.<n>D Diff2DGS outperforms state-of-the-art approaches in both appearance and geometry, reaching 38.02 dB PSNR on
arXiv Detail & Related papers (2026-02-20T16:14:21Z) - Landmark-Free Preoperative-to-Intraoperative Registration in Laparoscopic Liver Resection [50.388465935739376]
Liver registration by overlaying preoperative 3D models onto intraoperative 2D frames can assist surgeons in perceiving the spatial anatomy of the liver clearly for a higher surgical success rate.<n>Existing registration methods rely heavily on anatomical landmark-based, which encounter two major limitations.<n>We propose a landmark-free preoperative-to-intraoperative registration framework utilizing effective self-supervised learning.
arXiv Detail & Related papers (2025-04-21T14:55:57Z) - Submillimeter-Accurate 3D Lumbar Spine Reconstruction from Biplanar X-Ray Images: Incorporating a Multi-Task Network and Landmark-Weighted Loss [5.514961917579977]
This study presents a novel, fully automatic framework for high-precision 3D reconstruction from biplanar X-ray images.<n>The core of this method involves a novel multi-task deep learning network that simultaneously performs lumbar decomposition and landmark detection.<n>It sets a new benchmark by achieving sub-millimeter accuracy and completes the full reconstruction and measurement workflow in under 20 seconds.
arXiv Detail & Related papers (2025-03-18T15:00:39Z) - Epicardium Prompt-guided Real-time Cardiac Ultrasound Frame-to-volume Registration [50.602074919305636]
This paper introduces a lightweight end-to-end Cardiac Ultrasound frame-to-volume Registration network, termed CU-Reg.<n>We use epicardium prompt-guided anatomical clues to reinforce the interaction of 2D sparse and 3D dense features, followed by a voxel-wise local-global aggregation of enhanced features.
arXiv Detail & Related papers (2024-06-20T17:47:30Z) - On the Localization of Ultrasound Image Slices within Point Distribution
Models [84.27083443424408]
Thyroid disorders are most commonly diagnosed using high-resolution Ultrasound (US)
Longitudinal tracking is a pivotal diagnostic protocol for monitoring changes in pathological thyroid morphology.
We present a framework for automated US image slice localization within a 3D shape representation.
arXiv Detail & Related papers (2023-09-01T10:10:46Z) - Revisiting 3D Context Modeling with Supervised Pre-training for
Universal Lesion Detection in CT Slices [48.85784310158493]
We propose a Modified Pseudo-3D Feature Pyramid Network (MP3D FPN) to efficiently extract 3D context enhanced 2D features for universal lesion detection in CT slices.
With the novel pre-training method, the proposed MP3D FPN achieves state-of-the-art detection performance on the DeepLesion dataset.
The proposed 3D pre-trained weights can potentially be used to boost the performance of other 3D medical image analysis tasks.
arXiv Detail & Related papers (2020-12-16T07:11:16Z) - Tattoo tomography: Freehand 3D photoacoustic image reconstruction with
an optical pattern [49.240017254888336]
Photoacoustic tomography (PAT) is a novel imaging technique that can resolve both morphological and functional tissue properties.
A current drawback is the limited field-of-view provided by the conventionally applied 2D probes.
We present a novel approach to 3D reconstruction of PAT data that does not require an external tracking system.
arXiv Detail & Related papers (2020-11-10T09:27:56Z) - Enhanced 3D Myocardial Strain Estimation from Multi-View 2D CMR Imaging [0.0]
We propose an enhanced 3D myocardial strain estimation procedure, which combines complementary displacement information from multiple orientations of a single imaging modality (untagged CMR SSFP images)
We register the sets of short-axis, four-chamber and two-chamber views via a 2D non-rigid registration algorithm implemented in a commercial software (Segment, Medviso)
We then create a series of interpolating functions for the three directions of motion and use them to deform a tetrahedral mesh representation of a patient-specific left ventricle.
arXiv Detail & Related papers (2020-09-25T22:47:50Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.