Cross-Modality Structural Guidance in 3D Latent Diffusion for Robust FLAIR Super-Resolution
- URL: http://arxiv.org/abs/2606.25255v1
- Date: Wed, 24 Jun 2026 00:26:01 GMT
- Title: Cross-Modality Structural Guidance in 3D Latent Diffusion for Robust FLAIR Super-Resolution
- Abstract summary: High-resolution (HR) MRI acquisition is often hampered by scan time constraints.<n>Deep learning-based super-resolution methods often hallucinate anatomical details, which can compromise brain structural integrity.<n>We introduce MR-DiffuSR, a Multi-Resolution Diffusion-based Super-Resolution framework that incorporates HR T1w structural image priors to guide the restoration of thick-slice FLAIR scans.
- Score: 0.2959600957981674
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: High-resolution (HR) MRI acquisition is often hampered by scan time constraints, resulting in anisotropic or low-resolution scans (e.g., thick-slice FLAIR) that limit diagnostic accuracy. While deep learning-based super-resolution (SR) methods show promise, they often hallucinate anatomical details, which can compromise brain structural integrity. To mitigate this limitation, we introduce MR-DiffuSR, a Multi-Resolution Diffusion-based Super-Resolution framework that incorporates HR T1w structural image priors to guide the restoration of thick-slice FLAIR scans and operates in the 3D latent space. Our architecture introduces cross-modality structural swin-attention, which derives structural attention maps from the HR T1w and applies them to the low-resolution FLAIR latent features. This design disentangles anatomical structure from modality-specific contrast, effectively preventing hallucinations. Furthermore, we employ a mixed-scale degradation strategy, training the model on a continuum of downsampling factors to ensure robustness to varying slice thicknesses, while optimizing with a DINOv3-based perceptual loss to preserve high-frequency semantic details. Evaluated on the ADNI-4 dataset, MR-DiffuSR surpasses both CNN and 2D diffusion approaches, achieving an average PSNR of 32.46dB, SSIM of 0.97, and LPIPS of 0.07 across all downsampling factors. In downstream white matter hyperintensity segmentation, our model demonstrates exceptional robustness. While baseline performance collapses at 10x down-sampling (Dice: 0.51), MR-DiffuSR maintains a Dice score of 0.63, preserving utility even at 7mm equivalent slice thickness.
Related papers
- Shape Over Intensity: Directional Topological Encoding for False Positive Reduction in Intracranial Aneurysm Detection [0.0]
Automated detection of intracranial aneurysms (IAs) from CT angiography is severely hindered by high false-positive rates.<n>We propose a plug-and-play, topology-aware false-positive reduction framework evaluating the Smooth Euler Characteristic Transform (SECT)<n>SECT achieves an AUC of 0.943, substantially outperforming direction-agnostic methods (AUC 0.68), and exhibits a clinical performance inversion.
arXiv Detail & Related papers (2026-07-06T16:56:17Z) - Parameter-Efficient Adaptation of SAM 3 for Automated ITV Generation from 4DCT Images [0.0]
Four-dimensional computed tomography (4DCT) captures the full respiratory cycle of thoracic anatomy.<n>Current Internal Target Volume contouring process each phase in isolation, discarding temporal coherence and leaving vulnerable to phase-specific artifacts.<n>We present a framework that applies parameter-efficient fine-tuning to the Segment Anything Model 3 (SAM 3) via low-rank adaptation (LoRA)<n>With only seven annotated volumes, the framework retains over 95% of full-data accuracy, and the entire pipeline is trainable on a single consumer-grade GPU.
arXiv Detail & Related papers (2026-06-14T05:12:57Z) - Three-Dimensional Retinal Microvasculature Restoration in OCT Angiography [4.442929593591647]
We propose a deep learning algorithm for restoring anatomical vasculature from a single OCTA volume.<n>The proposed model significantly improved image quality compared with the original single OCTA volume.
arXiv Detail & Related papers (2026-06-03T19:23:09Z) - D3Seg: Dependency-Aware Diffusion for Brain Tumor Segmentation with Missing Modalities [54.87947751720332]
We propose a novel segmentation model D3Seg to maintain stable performance under missing-modality settings.<n>The proposed model achieves approximately 1.5-2.0% Dice improvement on enhancing tumor (ET) and around 1.0% on tumor core (TC) across multiple missing modality configurations.
arXiv Detail & Related papers (2026-05-21T09:55:42Z) - CAHAL: Clinically Applicable resolution enHAncement for Low-resolution MRI scans [29.281962308908195]
Large-scale automated morphometric analysis of brain MRI is limited by the thick-slice.<n>Existing generative super-resolution methods produce visually compelling isotropic volumes but often introduce anatomical hallucinations.<n>We propose CAHAL (Clinically Applicable resolution enHAncement for Low-resolution MRI scans), a hallucination-robust, physics-informed resolution enhancement framework.
arXiv Detail & Related papers (2026-04-20T19:45:11Z) - DSA-SRGS: Super-Resolution Gaussian Splatting for Dynamic Sparse-View DSA Reconstruction [67.42242016220122]
Digital subtraction angiography is a key imaging technique for the auxiliary diagnosis and treatment of cerebrovascular diseases.<n>Recent advancements in gaussian splatting and dynamic neural representations have enabled robust 3D vessel reconstruction from sparse dynamic inputs.<n>This paper proposes DSA-SRGS, the first super-resolution gaussian splatting framework for dynamic sparse-view DSA reconstruction.
arXiv Detail & Related papers (2026-03-05T03:41:08Z) - Multimodal Visual Surrogate Compression for Alzheimer's Disease Classification [69.87877580725768]
Multimodal Visual Surrogate Compression (MVSC) learns to compress and adapt large 3D sMRI volumes into compact 2D features.<n>MVSC has two key components: a Volume Context that captures global cross-slice context under textual guidance, and an Adaptive Slice Fusion module that aggregates slice-level information in a text-enhanced, patch-wise manner.
arXiv Detail & Related papers (2026-01-29T13:05:46Z) - Rethinking Diffusion Model-Based Video Super-Resolution: Leveraging Dense Guidance from Aligned Features [51.5076190312734]
Video Super-Resolution approaches suffer from error accumulation, spatial artifacts, and a trade-off between perceptual quality and fidelity.<n>We propose a novelly Guided diffusion model with Aligned Features for Video Super-Resolution (DGAF-VSR)<n>Experiments on synthetic and real-world datasets demonstrate that DGAF-VSR surpasses state-of-the-art methods in key aspects of VSR.
arXiv Detail & Related papers (2025-11-21T03:40:45Z) - Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement [0.0]
We present an image-based harmonization framework for 3D T1-weighted brain MRI.<n>The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features.<n>Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings.
arXiv Detail & Related papers (2025-10-24T23:19:02Z) - PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurement [63.007237197267834]
Existing deep learning methods are mostly physiological monitoring and lack theoretical robustness.<n>We propose a physics-informed r paradigm derived from the Navier-Stokes equations of hemodynamics, showing that the pulse signal follows a second-order system.<n>This provides a theoretical justification for using a Temporal Conal Network (TCN)<n>Phase-Net achieves state-of-the-art performance with strong efficiency, offering a theoretically grounded and deployment-ready r solution.
arXiv Detail & Related papers (2025-09-29T14:36:45Z) - Weakly supervised segmentation of intracranial aneurysms using a novel 3D focal modulation UNet [0.5106162890866905]
We propose FocalSegNet, a novel 3D focal modulation UNet, to detect an aneurysm and offer an initial, coarse segmentation of it from time-of-flight MRA image patches.
We trained and evaluated our model on a public dataset, and in terms of UIA detection, our model showed a low false-positive rate of 0.21 and a high sensitivity of 0.80.
arXiv Detail & Related papers (2023-08-06T03:28:08Z) - Orthogonal Matrix Retrieval with Spatial Consensus for 3D Unknown-View
Tomography [58.60249163402822]
Unknown-view tomography (UVT) reconstructs a 3D density map from its 2D projections at unknown, random orientations.
The proposed OMR is more robust and performs significantly better than the previous state-of-the-art OMR approach.
arXiv Detail & Related papers (2022-07-06T21:40:59Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.