ProSAC-CT: Progressive Spectral-Anatomical Co-Guided Multi-Stage Diffusion Model for Low-Dose CT Denoising
- URL: http://arxiv.org/abs/2607.01756v1
- Date: Thu, 02 Jul 2026 06:13:43 GMT
- Title: ProSAC-CT: Progressive Spectral-Anatomical Co-Guided Multi-Stage Diffusion Model for Low-Dose CT Denoising
- Abstract summary: We propose ProSAC-CT, a spectral-anatomical co-guided diffusion model for image-domain LDCT denoising.<n>ProSAC-CT integrates an anatomical-prior-guided conditioning module, a residual frequency-domain decoupling stage, and a time-step-decoupling denoising decoder.<n> Experiments show that ProSAC-CT improves image fidelity, structural similarity, perceptual quality, and information preservation over representative methods.
- Score: 4.802209002705593
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Low-dose computed tomography (LDCT) reduces radiation exposure but introduces stronger quantum noise, streak artifacts, and local texture degradation, which can obscure anatomical boundaries and weaken low-contrast structures. Diffusion models are promising for LDCT denoising by progressively recovering normal-dose CT (NDCT) images from degraded LDCT inputs, but existing methods often suffer from insufficient anatomical guidance, uncertain frequency-dependent recovery, and uniform reverse-process modeling. We propose ProSAC-CT, a progressive spectral-anatomical co-guided multi-stage diffusion model for image-domain LDCT denoising. ProSAC-CT integrates an anatomical-prior-guided conditioning (APGC) module, a residual frequency-domain decoupling stage (RFDDS), and a time-step-decoupling denoising decoder (TD3). APGC extracts LDCT-derived structural guidance, RFDDS enhances frequency-aware representations, and TD3 assigns them to different reverse-diffusion stages for anatomical stabilization, boundary refinement, and fine-detail recovery. Experiments on four LDCT degradation benchmarks show that ProSAC-CT improves image fidelity, structural similarity, perceptual quality, and information preservation over representative methods while better preserving boundary-sensitive anatomical details. Downstream anatomical-region classification on Mayo-2020 further indicates that ProSAC-CT retains task-relevant anatomical information, supporting its practical use for low-dose CT denoising.
Related papers
- A deep dictionary network-based foundation model for ultra-low-dose CT denoising [49.70293041079032]
Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality.<n>Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios.<n>We propose an architecture?able foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising.
arXiv Detail & Related papers (2026-09-11T05:14:08Z) - DeVAR: Low-Dose CT Denoising via Visual Autoregressive Modeling [14.938419722549575]
Low-dose CT (LDCT) protocols reduce radiation risks but inevitably suffer from severe noise and artifacts that compromise diagnostic accuracy.<n>We propose a novel generative framework that applies visual autore modeling to LDCT denoising for the first time.<n>Our hybrid NDCT decoder seamlessly integrates continuous and discrete latents to reconstruct high-fidelity, detail-preserved images.
arXiv Detail & Related papers (2026-06-26T09:55:37Z) - PHASOR: Anatomy- and Phase-Consistent Volumetric Diffusion for CT Virtual Contrast Enhancement [60.81732730684265]
This paper introduces PHASOR, a volumetric diffusion framework for high-fidelity virtual contrast enhancement (VCE)<n>By treating CT volumes as coherent sequences, we leverage a video diffusion model to enhance structural coherence and volumetric accuracy.<n>To ensure anatomy-phase consistent synthesis, we introduce two complementary modules. First, anatomy-routed mixture-of-experts (AR-MoE) anchors distinct enhancement patterns to anatomical semantics, with organ-specific memory to capture salient details.<n>Second, intensity-phase aware representation alignment (IP-REPA) highlights intricate contrast signals while mitigating the impact of imperfect spatial alignment.
arXiv Detail & Related papers (2026-04-01T15:57:18Z) - Structure-constrained Language-informed Diffusion Model for Unpaired Low-dose Computed Tomography Angiography Reconstruction [72.80209358480424]
overdose of iodinated contrast media (ICM) can cause kidney damage and life-threatening allergic reactions.<n>Deep learning methods can generate CT images of normal-dose ICM from low-dose ICM, reducing the required dose.<n>We propose a Structure-constrained Language-informed Diffusion Model (SLDM) that integrates structural synergy and spatial intelligence.
arXiv Detail & Related papers (2026-01-28T06:54:06Z) - EqDiff-CT: Equivariant Conditional Diffusion model for CT Image Synthesis from CBCT [43.92108185590778]
Cone-beam computed tomography (CBCT) is widely used for imageguided radiotherapy (IGRT)<n>We propose a novel diffusion-based conditional generative model, coined EqDiff-CT, to synthesize high-quality CT images from CBCT.
arXiv Detail & Related papers (2025-09-26T05:51:59Z) - FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT Denoising [55.04342933312839]
We propose FoundDiff, a foundational diffusion model for unified and generalizable low-dose computed tomography (CT) denoising.<n>FoundDiff employs a two-stage strategy: (i) dose-anatomy perception and (ii) adaptive denoising.<n>First, we develop a dose- and anatomy-aware contrastive language image pre-training model (DA-CLIP) to achieve robust dose and anatomy perception.<n>Second, we design a dose- and anatomy-aware diffusion model (DA-Diff) to perform adaptive and generalizable denoising.
arXiv Detail & Related papers (2025-08-24T11:03:56Z) - Prior Frequency Guided Diffusion Model for Limited Angle (LA)-CBCT Reconstruction [2.960150120524893]
Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy.
LA-CBCT reconstruction suffers from severe under-sampling artifacts, making it a highly ill-posed inverse problem.
We developed a diffusion model-based framework, prior frequency-guided diffusion model (PFGDM) for robust and structure-preserving LA-CBCT reconstruction.
arXiv Detail & Related papers (2024-04-01T19:41:33Z) - WIA-LD2ND: Wavelet-based Image Alignment for Self-supervised Low-Dose CT Denoising [74.14134385961775]
We introduce a novel self-supervised CT image denoising method called WIA-LD2ND, only using NDCT data.
WIA-LD2ND comprises two modules: Wavelet-based Image Alignment (WIA) and Frequency-Aware Multi-scale Loss (FAM)
arXiv Detail & Related papers (2024-03-18T11:20:11Z) - Rotational Augmented Noise2Inverse for Low-dose Computed Tomography
Reconstruction [83.73429628413773]
Supervised deep learning methods have shown the ability to remove noise in images but require accurate ground truth.
We propose a novel self-supervised framework for LDCT, in which ground truth is not required for training the convolutional neural network (CNN)
Numerical and experimental results show that the reconstruction accuracy of N2I with sparse views is degrading while the proposed rotational augmented Noise2Inverse (RAN2I) method keeps better image quality over a different range of sampling angles.
arXiv Detail & Related papers (2023-12-19T22:40:51Z) - Feature-oriented Deep Learning Framework for Pulmonary Cone-beam CT
(CBCT) Enhancement with Multi-task Customized Perceptual Loss [9.59233136691378]
Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy.
Recent deep learning-based CBCT enhancement methods have shown promising results in suppressing artifacts.
We propose a novel feature-oriented deep learning framework that translates low-quality CBCT images into high-quality CT-like imaging.
arXiv Detail & Related papers (2023-11-01T10:09:01Z) - Cross-domain Denoising for Low-dose Multi-frame Spiral Computed Tomography [20.463308418655526]
X-ray exposure raises concerns about potential health risks such as cancer.
The desire for lower radiation doses has driven researchers to improve reconstruction quality.
This paper proposes a two-stage method for the commercially available multi-slice spiral CT scanners.
arXiv Detail & Related papers (2023-04-21T09:30:22Z) - Anatomically constrained CT image translation for heterogeneous blood
vessel segmentation [3.88838725116957]
Anatomical structures in contrast-enhanced CT (ceCT) images can be challenging to segment due to variability in contrast medium diffusion.
To limit the radiation dose, generative models could be used to synthesize one modality, instead of acquiring it.
CycleGAN has attracted particular attention because it alleviates the need for paired data.
We present an extension of CycleGAN to generate high fidelity images, with good structural consistency.
arXiv Detail & Related papers (2022-10-04T16:14:49Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.