Luminosity-Adaptive Contrast Enhancement Using CLAHE for Retinal Fundus Images with Quantitative Validation and Comparative Analysis
- URL: http://arxiv.org/abs/2607.17691v1
- Date: Mon, 20 Jul 2026 08:39:13 GMT
- Title: Luminosity-Adaptive Contrast Enhancement Using CLAHE for Retinal Fundus Images with Quantitative Validation and Comparative Analysis
- Abstract summary: Clinical utility of fundus images is routinely compromised by non-uniform illumination, motion blur, and low contrast.<n>This study proposes a two-stage image enhancement pipeline combining luminosity correction via HSV colour space decomposition with Contrast Limited Adaptive Histogram Equalization.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Background: Retinal fundus imaging is central to the early diagnosis of sight-threatening conditions including diabetic retinopathy, glaucoma, and retinal vein occlusion. Clinical utility of fundus images is routinely compromised by non-uniform illumination, motion blur, and low contrast - artefacts that increase the risk of diagnostic error. Effective image enhancement is therefore a prerequisite for reliable computer-aided ophthalmic diagnosis. Methods: This study proposes a two-stage image enhancement pipeline combining luminosity correction via HSV colour space decomposition with Contrast Limited Adaptive Histogram Equalization (CLAHE) applied exclusively to the Value (V) channel. Experiments are conducted on the publicly available DRIVE dataset (40 retinal fundus images, 584 x 565 pixels, Canon CR5 camera, ophthalmologist-annotated ground truth). Quantitative evaluation employs Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM), and Contrast-to-Noise Ratio (CNR). Baseline comparisons include standard Histogram Equalization (HE) and Adaptive Histogram Equalization (AHE). A binary masking step is subsequently applied to isolate hyper-reflective regions consistent with vascular pathology. Results: The proposed method achieves PSNR = 29.3 dB, SSIM = 0.91, and CNR = 3.12 - outperforming HE (PSNR = 21.4 dB, SSIM = 0.74) and AHE (PSNR = 23.1 dB, SSIM = 0.79) across all metrics, with an average processing time of 0.14 seconds per image. Conclusions: The combined luminosity-CLAHE pipeline yields measurably superior contrast and structural fidelity compared to established baseline methods, with processing speed compatible with clinical screening workflows. Limitations and directions for deep-learning-based comparison are discussed.
Related papers
- Three-Dimensional Retinal Microvasculature Restoration in OCT Angiography [4.442929593591647]
We propose a deep learning algorithm for restoring anatomical vasculature from a single OCTA volume.<n>The proposed model significantly improved image quality compared with the original single OCTA volume.
arXiv Detail & Related papers (2026-06-03T19:23:09Z) - Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts [56.74856091904914]
We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction.<n>ScanCLIP derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features.<n>A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction.
arXiv Detail & Related papers (2026-05-29T02:48:23Z) - A Novel Retinal Image Contrast Enhancement -- Fuzzy-Based Method [0.0]
This paper proposes a novel model that utilizes the linear blending of Fuzzy Contrast Enhancement (FCE) and Contrast Limited Adaptive Histogram Equalization (CLAHE) to enhance the retinal image for retinal vascular structure segmentation.<n>It was evident in this paper that the combination of FCE and CLAHE methods showed major improvement.
arXiv Detail & Related papers (2025-02-25T04:54:24Z) - Cycle-Constrained Adversarial Denoising Convolutional Network for PET Image Denoising: Multi-Dimensional Validation on Large Datasets with Reader Study and Real Low-Dose Data [9.160782425067712]
We propose a Cycle-versa Adrial Denoising Convolutional Network (Cycle-DCN) to reconstruct full-dose-quality images from low-dose scans.
Experiments were conducted on a large dataset consisting of raw PET brain data from 1,224 patients.
Cycle-DCN significantly improves average Peak Signal-to-Noise Ratio (PSNR), SSIM, and Normalized Root Mean Square Error (NRMSE) across three dose levels.
arXiv Detail & Related papers (2024-10-31T04:34:28Z) - Enhanced Denoising of Optical Coherence Tomography Images Using Residual U-Net [0.0]
We propose an enhanced denoising model using a Residual U-Net architecture that effectively diminishes noise and improves image clarity.
Peak Signal Noise Ratio (PSNR) was 34.343 $pm$ 1.113 for PS OCT images, and Structural Similarity Index Measure (SSIM) values were 0.885 $pm$ 0.030.
arXiv Detail & Related papers (2024-07-18T01:35:03Z) - Gadolinium dose reduction for brain MRI using conditional deep learning [66.99830668082234]
Two main challenges for these approaches are the accurate prediction of contrast enhancement and the synthesis of realistic images.
We address both challenges by utilizing the contrast signal encoded in the subtraction images of pre-contrast and post-contrast image pairs.
We demonstrate the effectiveness of our approach on synthetic and real datasets using various scanners, field strengths, and contrast agents.
arXiv Detail & Related papers (2024-03-06T08:35:29Z) - Deep-Learning-based Vasculature Extraction for Single-Scan Optical
Coherence Tomography Angiography [9.77526300425824]
We propose a vasculature extraction pipeline that uses only one-repeated OCT scan to generate OCTA images.
The pipeline is based on the proposed Vasculature Extraction Transformer (VET), which leverages convolutional projection to better learn the spatial relationships between image patches.
arXiv Detail & Related papers (2023-04-17T13:55:26Z) - OADAT: Experimental and Synthetic Clinical Optoacoustic Data for
Standardized Image Processing [62.993663757843464]
Optoacoustic (OA) imaging is based on excitation of biological tissues with nanosecond-duration laser pulses followed by detection of ultrasound waves generated via light-absorption-mediated thermoelastic expansion.
OA imaging features a powerful combination between rich optical contrast and high resolution in deep tissues.
No standardized datasets generated with different types of experimental set-up and associated processing methods are available to facilitate advances in broader applications of OA in clinical settings.
arXiv Detail & Related papers (2022-06-17T08:11:26Z) - Harmonizing Pathological and Normal Pixels for Pseudo-healthy Synthesis [68.5287824124996]
We present a new type of discriminator, the segmentor, to accurately locate the lesions and improve the visual quality of pseudo-healthy images.
We apply the generated images into medical image enhancement and utilize the enhanced results to cope with the low contrast problem.
Comprehensive experiments on the T2 modality of BraTS demonstrate that the proposed method substantially outperforms the state-of-the-art methods.
arXiv Detail & Related papers (2022-03-29T08:41:17Z) - CyTran: A Cycle-Consistent Transformer with Multi-Level Consistency for
Non-Contrast to Contrast CT Translation [56.622832383316215]
We propose a novel approach to translate unpaired contrast computed tomography (CT) scans to non-contrast CT scans.
Our approach is based on cycle-consistent generative adversarial convolutional transformers, for short, CyTran.
Our empirical results show that CyTran outperforms all competing methods.
arXiv Detail & Related papers (2021-10-12T23:25:03Z) - OCT-GAN: Single Step Shadow and Noise Removal from Optical Coherence
Tomography Images of the Human Optic Nerve Head [47.812972855826985]
We developed a single process that successfully removed both noise and retinal shadows from unseen single-frame B-scans within 10.4ms.
The proposed algorithm reduces the necessity for long image acquisition times, minimizes expensive hardware requirements and reduces motion artifacts in OCT images.
arXiv Detail & Related papers (2020-10-06T08:32:32Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.