The Calibration Channel Determines the Bayes-Error Proxy: An Exact Law for Temperature-Induced Distortion
- URL: http://arxiv.org/abs/2607.18162v1
- Date: Mon, 20 Jul 2026 17:07:26 GMT
- Title: The Calibration Channel Determines the Bayes-Error Proxy: An Exact Law for Temperature-Induced Distortion
- Abstract summary: Bayes-error estimator beta(z) = E[min(z, 1-z)] of Ishida et al. estimates the irreducible error of a binary task directly from probability-valued labels.<n>Recent work by Ushio et al. showed that this estimator is fragile when the probabilities are not the true posterior.<n>We characterize exactly how the most widely used post-hoc calibration map -- temperature scaling -- distorts the proxy.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: The soft-label Bayes-error estimator beta(z) = E[min(z, 1-z)] of Ishida et al. estimates the irreducible error of a binary task directly from probability-valued labels. Recent work by Ushio et al. showed that this estimator is fragile when the probabilities are not the true posterior: even perfectly calibrated soft labels can yield a substantially inaccurate estimate, and they propose isotonic calibration as a consistent remedy. We complement that line of work by characterizing exactly how the most widely used post-hoc calibration map -- temperature scaling -- distorts the proxy. We prove an exact, model-free identity reducing the temperature-scaled proxy to the classifier's margin distribution, from which we obtain (i) strict monotonicity in the temperature and (ii) a continuous bijection from the temperature axis onto the open interval (0, 1/2), so that a fixed classifier -- with fixed decisions and fixed 0-1 error -- can be made to report any proxy value whatsoever. Under a Gaussian model of the logits we further derive a two-parameter closed form for the entire proxy-versus-temperature curve. Across CIFAR-10, Fashion-MNIST, and SVHN (eight binary tasks), the proxy varies by 56x to 980x at constant test error, the closed form reproduces the empirical curve to within 0.018, and the calibration temperature that minimizes the expected calibration error does not coincide with any stable proxy value. Our results give a precise, predictive account of the distortion whose existence motivates calibration-based remedies, and they reinforce the practical recommendation that a proxy value is meaningful only together with the mechanism that produced its probabilities.
Related papers
- EDGE: a closed-form directed test for the calibration of probabilistic binary classifiers [0.0]
We propose EDGE, a calibration test for the canonical probabilistic classifier, logistic regression.<n> EDGE reads the same binned predicted-observed table a reliability diagram plots, and projects its standardized bin residuals onto a small pre-specified basis of smooth calibration-distortion.<n>Across link and feature misspecification the pre-specified default led or tied every rival binned test on the fitted index in 19 of 22 detectable scenarios, and stayed computable where the refit-based Stukel score test separates in 20% to 28% of samples.
arXiv Detail & Related papers (2026-08-20T19:06:05Z) - The Minimax Rate of Second-Order Calibration [8.791341107339637]
We characterize the minimax rate of estimating the second-order calibration error for binary classification.<n>As a corollary, we give the first finite-sample guarantee for second-order Platt scaling.
arXiv Detail & Related papers (2026-05-08T14:41:56Z) - Geometric Calibration and Neutral Zones for Uncertainty-Aware Multi-Class Classification [0.0]
This work bridges information geometry and statistical learning, offering formal guarantees for uncertainty-aware classification in applications requiring rigorous validation.<n> Empirical validation on Adeno-Associated Virus classification demonstrates that the two-stage framework captures 72.5% of errors while deferring 34.5% of samples, reducing automated decision error rates from 16.8% to 6.9%.
arXiv Detail & Related papers (2025-11-26T01:29:49Z) - On the good reliability of an interval-based metric to validate prediction uncertainty for machine learning regression tasks [0.0]
This study presents an opportunistic approach to a (more) reliable validation method for prediction uncertainty average calibration.
Considering that variance-based calibration metrics are quite sensitive to the presence of heavy tails in the uncertainty and error distributions, a shift is proposed to an interval-based metric, the Prediction Interval Coverage Probability (PICP)
The resulting PICPs are more quickly and reliably tested than variance-based calibration metrics.
arXiv Detail & Related papers (2024-08-23T14:16:10Z) - Orthogonal Causal Calibration [55.28164682911196]
We develop general algorithms for reducing the task of causal calibration to that of calibrating a standard (non-causal) predictive model.<n>Our results are exceedingly general, showing that essentially any existing calibration algorithm can be used in causal settings.
arXiv Detail & Related papers (2024-06-04T03:35:25Z) - Calibrated Uncertainty Quantification for Operator Learning via
Conformal Prediction [95.75771195913046]
We propose a risk-controlling quantile neural operator, a distribution-free, finite-sample functional calibration conformal prediction method.
We provide a theoretical calibration guarantee on the coverage rate, defined as the expected percentage of points on the function domain.
Empirical results on a 2D Darcy flow and a 3D car surface pressure prediction task validate our theoretical results.
arXiv Detail & Related papers (2024-02-02T23:43:28Z) - The Lipschitz-Variance-Margin Tradeoff for Enhanced Randomized Smoothing [85.85160896547698]
Real-life applications of deep neural networks are hindered by their unsteady predictions when faced with noisy inputs and adversarial attacks.
We show how to design an efficient classifier with a certified radius by relying on noise injection into the inputs.
Our novel certification procedure allows us to use pre-trained models with randomized smoothing, effectively improving the current certification radius in a zero-shot manner.
arXiv Detail & Related papers (2023-09-28T22:41:47Z) - A Consistent and Differentiable Lp Canonical Calibration Error Estimator [21.67616079217758]
Deep neural networks are poorly calibrated and tend to output overconfident predictions.
We propose a low-bias, trainable calibration error estimator based on Dirichlet kernel density estimates.
Our method has a natural choice of kernel, and can be used to generate consistent estimates of other quantities.
arXiv Detail & Related papers (2022-10-13T15:11:11Z) - Sample-dependent Adaptive Temperature Scaling for Improved Calibration [95.7477042886242]
Post-hoc approach to compensate for neural networks being wrong is to perform temperature scaling.
We propose to predict a different temperature value for each input, allowing us to adjust the mismatch between confidence and accuracy.
We test our method on the ResNet50 and WideResNet28-10 architectures using the CIFAR10/100 and Tiny-ImageNet datasets.
arXiv Detail & Related papers (2022-07-13T14:13:49Z) - T-Cal: An optimal test for the calibration of predictive models [49.11538724574202]
We consider detecting mis-calibration of predictive models using a finite validation dataset as a hypothesis testing problem.
detecting mis-calibration is only possible when the conditional probabilities of the classes are sufficiently smooth functions of the predictions.
We propose T-Cal, a minimax test for calibration based on a de-biased plug-in estimator of the $ell$-Expected Error (ECE)
arXiv Detail & Related papers (2022-03-03T16:58:54Z) - Calibration of Neural Networks using Splines [51.42640515410253]
Measuring calibration error amounts to comparing two empirical distributions.
We introduce a binning-free calibration measure inspired by the classical Kolmogorov-Smirnov (KS) statistical test.
Our method consistently outperforms existing methods on KS error as well as other commonly used calibration measures.
arXiv Detail & Related papers (2020-06-23T07:18:05Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.