MVP-Tac: A Miniaturized Dual-Modal Vision and Photoelastic Tactile Sensor for Robot-Assisted Minimally Invasive Surgery
- URL: http://arxiv.org/abs/2607.18660v1
- Date: Tue, 21 Jul 2026 03:08:14 GMT
- Title: MVP-Tac: A Miniaturized Dual-Modal Vision and Photoelastic Tactile Sensor for Robot-Assisted Minimally Invasive Surgery
- Abstract summary: MVP-Tac is a vision-based tactile sensor that provides co-located vision and tactile sensing.<n>A semi-transparent membrane and controllable illumination enable switching between visual mode and tactile mode.<n> MVP-Tac provides a practical path toward restoring clinically useful palpation in RMIS.
- Score: 15.932367783395812
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Robot-assisted minimally invasive surgery (RMIS) offers major benefits over open and conventional laparoscopic procedures, yet it still lacks tactile feedback for palpation while operating under strict requirements to preserve reliable vision for navigation and safety. In practice, visual feedback is indispensable, and tactile solutions that cannot coexist with vision are difficult to translate into RMIS tools. To address both needs, we introduce MVP-Tac, a compact, vision-based tactile sensor that provides co-located vision and tactile sensing. MVP-Tac uses reflective photoelastic imaging: a thin photoelastic elastomer produces stress-dependent interferograms under contact that are captured by an embedded camera through a miniaturized reflective polariscope. A semi-transparent membrane and controllable illumination enable switching between visual mode and tactile mode, enabling tactile perception without sacrificing vision. We validate MVP-Tac through force calibration in the 0 to 2 N range and demonstrate its potential for tumor palpation via video-based hardness classification on tissue phantoms, achieving 97% accuracy for exposed-tumor classification and 92% accuracy for subdermal-tumor classification. Finally, we conduct a simulated colonoscopy to validate both visual and tactile modalities in a constrained lumen, including vision-guided 3D photomapping of the luminal wall and in situ hardness classification of localized nodules. Overall, MVP-Tac provides a practical path toward restoring clinically useful palpation in RMIS while maintaining essential visual feedback. The design, fabrication, and firmware of MVP-Tac are open-sourced at https://mvp-tac.github.io/
Related papers
- MISTac: A Vision-Based Tactile Sensor for Minimally Invasive Surgery [3.2752052569216197]
Minimally invasive and robot-assisted surgery offer many advantages over traditional open surgery, but deprive surgeons of tactile feedback.<n>We introduce the MISTac, a high resolution vision-based tactile sensor specifically designed for palpation in MIS.<n>The sensor has a replaceable sensor tip with a diameter of 8 mm which allows it to fit through the trocars used in minimally invasive surgery.
arXiv Detail & Related papers (2026-08-14T15:52:06Z) - Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts [56.74856091904914]
We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction.<n>ScanCLIP derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features.<n>A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction.
arXiv Detail & Related papers (2026-05-29T02:48:23Z) - Accelerating 3D Photoacoustic Computed Tomography with End-to-End Physics-Aware Neural Operators [74.65171736966131]
Photoacoustic computed tomography (PACT) combines optical contrast with ultrasonic resolution, achieving deep-tissue imaging beyond the optical diffusion limit.<n>Current implementations require dense transducer arrays and prolonged acquisition times, limiting clinical translation.<n>We introduce Pano, an end-to-end physics-aware model that directly learns the inverse acoustic mapping from sensor measurements to volumetric reconstructions.
arXiv Detail & Related papers (2025-09-11T23:12:55Z) - EndoControlMag: Robust Endoscopic Vascular Motion Magnification with Periodic Reference Resetting and Hierarchical Tissue-aware Dual-Mask Control [10.426745597034204]
We introduce EndoControlMag, a training-free framework with mask-conditioned vascular motion magnification tailored to endoscopic environments.<n>Our approach features two key modules: a Periodic Reference Resetting scheme that divides videos into short overlapping clips with dynamically updated reference frames to prevent error accumulation.<n>We evaluate EndoControlMag on our EndoVMM24 dataset spanning four different surgery types and various challenging scenarios.
arXiv Detail & Related papers (2025-07-21T06:47:44Z) - Monocular Marker-free Patient-to-Image Intraoperative Registration for Cochlear Implant Surgery [4.250558597144547]
Our framework seamlessly integrates with monocular surgical microscopes, making it highly practical for clinical use without additional hardware dependencies and requirements.<n>Our results suggest that our approach achieves clinically relevant accuracy in predicting 6D camera poses for registering 3D preoperative CT scans to 2D surgical scenes with an angular error within 10 degrees in most cases.
arXiv Detail & Related papers (2025-05-23T21:15:00Z) - FLex: Joint Pose and Dynamic Radiance Fields Optimization for Stereo Endoscopic Videos [79.50191812646125]
Reconstruction of endoscopic scenes is an important asset for various medical applications, from post-surgery analysis to educational training.
We adress the challenging setup of a moving endoscope within a highly dynamic environment of deforming tissue.
We propose an implicit scene separation into multiple overlapping 4D neural radiance fields (NeRFs) and a progressive optimization scheme jointly optimizing for reconstruction and camera poses from scratch.
This improves the ease-of-use and allows to scale reconstruction capabilities in time to process surgical videos of 5,000 frames and more; an improvement of more than ten times compared to the state of the art while being agnostic to external tracking information
arXiv Detail & Related papers (2024-03-18T19:13:02Z) - Monocular Microscope to CT Registration using Pose Estimation of the
Incus for Augmented Reality Cochlear Implant Surgery [3.8909273404657556]
We develop a method that permits direct 2D-to-3D registration of the view microscope video to the pre-operative Computed Tomography (CT) scan without the need for external tracking equipment.
Our results demonstrate the accuracy with an average rotation error of less than 25 degrees and a translation error of less than 2 mm, 3 mm, and 0.55% for the x, y, and z axes, respectively.
arXiv Detail & Related papers (2024-03-12T00:26:08Z) - Robot-Assisted Deep Venous Thrombosis Ultrasound Examination using
Virtual Fixture [45.97156332608481]
Deep Venous Thrombosis (DVT) is a common vascular disease with blood clots inside deep veins, which may block blood flow or even cause a life-threatening pulmonary embolism.
A typical exam for DVT using ultrasound (US) imaging is by pressing the target vein until its lumens is fully compressed.
We present a robotic US system with a novel hybrid force motion control scheme ensuring position and force tracking accuracy, and soft landing of the probe onto the target surface.
arXiv Detail & Related papers (2024-01-04T21:02:39Z) - EyeLS: Shadow-Guided Instrument Landing System for Intraocular Target
Approaching in Robotic Eye Surgery [51.05595735405451]
Robotic ophthalmic surgery is an emerging technology to facilitate high-precision interventions such as retina penetration in subretinal injection and removal of floating tissues in retinal detachment.
Current image-based methods cannot effectively estimate the needle tip's trajectory towards both retinal and floating targets.
We propose to use the shadow positions of the target and the instrument tip to estimate their relative depth position.
Our method succeeds target approaching on a retina model, and achieves an average depth error of 0.0127 mm and 0.3473 mm for floating and retinal targets respectively in the surgical simulator.
arXiv Detail & Related papers (2023-11-15T09:11:37Z) - LightNeuS: Neural Surface Reconstruction in Endoscopy using Illumination Decline [45.1300649322217]
We propose a new approach to 3D reconstruction from sequences of images acquired by monocular endoscopes.<n>It is based on two key insights. First, endoluminal cavities are watertight, a property naturally enforced by modeling them in terms of a signed distance function.<n>Second, the scene illumination is variable. It comes from the endoscope's light sources and decays with the inverse of the squared distance to the surface.
arXiv Detail & Related papers (2023-09-06T06:41:40Z) - Learning How To Robustly Estimate Camera Pose in Endoscopic Videos [5.073761189475753]
We propose a solution for stereo endoscopes that estimates depth and optical flow to minimize two geometric losses for camera pose estimation.
Most importantly, we introduce two learned adaptive per-pixel weight mappings that balance contributions according to the input image content.
We validate our approach on the publicly available SCARED dataset and introduce a new in-vivo dataset, StereoMIS.
arXiv Detail & Related papers (2023-04-17T07:05:01Z) - OmniTact: A Multi-Directional High Resolution Touch Sensor [109.28703530853542]
Existing tactile sensors are either flat, have small sensitive fields or only provide low-resolution signals.
We introduce OmniTact, a multi-directional high-resolution tactile sensor.
We evaluate the capabilities of OmniTact on a challenging robotic control task.
arXiv Detail & Related papers (2020-03-16T01:31:29Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.