SCMA: Structure-Conditioned and Metal-Aware Flow Matching for CT Metal Artifact Reduction
- URL: http://arxiv.org/abs/2607.28759v2
- Date: Mon, 03 Aug 2026 10:50:42 GMT
- Title: SCMA: Structure-Conditioned and Metal-Aware Flow Matching for CT Metal Artifact Reduction
- Abstract summary: Flow Matching learns a continuous-time velocity field that deterministically transports a source distribution to a target distribution.<n>We propose SCMA, a structure-conditioned and metal-aware Flow Matching framework.<n> Experiments on simulated and real CT data demonstrate that SCMA more effectively suppresses metal artifacts, preserves local anatomical structures, and reduces hallucination-like structures inconsistent with projection measurements.
- Score: 3.3849225808441346
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis. Existing metal artifact reduction (MAR) methods remain limited: optimization-based methods may leave residual artifacts or blur structures, regression networks may generalize poorly across scenarios, and generative models without sample-specific structural guidance and physical constraints may produce anatomically inconsistent structures. Flow Matching learns a continuous-time velocity field that deterministically transports a source distribution to a target distribution, providing a flexible MAR prior. However, standard unconditional Flow Matching does not exploit sample-specific structure, spatially nonuniform metal-induced degradation, or measured projections. To address these limitations, we propose SCMA, a structure-conditioned and metal-aware Flow Matching framework. First, a linear-interpolation-corrected image is fed into the velocity network with the intermediate state as a sample-specific structural condition, guiding inference toward artifact-free CT images while preserving anatomy. Second, time-varying spatial weights from the metal mask and its distance transform are incorporated into the Flow Matching loss to emphasize severe degradation within and around metal regions. Finally, conditional Flow Matching updates alternate with projection-consistency correction during inference, allowing reliable measurements outside metal traces to constrain predictions. Experiments on simulated and real CT data demonstrate that SCMA more effectively suppresses metal artifacts, preserves local anatomical structures, and reduces hallucination-like structures inconsistent with projection measurements than representative MAR methods.
Related papers
- Splat-Based Metal Artifact Reduction in Cone-Beam CT via Compact Attenuation Modeling [21.680060395853953]
We introduce a splat-based metal artifact reduction framework that incorporates a physically grounded polychromatic forward model into a continuous Gaussian representation for cone-beam CT.<n>Experiments on simulated and real cone-beam CT scans show that our method converges significantly faster and suppresses metal artifacts more effectively than existing reconstruction and neural field-based approaches.
arXiv Detail & Related papers (2026-08-05T12:30:13Z) - Layout-Guided Controllable Pathology Image Generation with In-Context Diffusion Transformers [57.54843029965778]
Controllable pathology image synthesis requires reliable regulation of spatial layout, tissue morphology, and semantic detail.<n>We propose In-Context Diffusion Transformer (IC-DiT), a layout-aware generative model that incorporates spatial layouts, textual descriptions, and visual embeddings into a unified diffusion transformer.<n>IC-DiT achieves higher fidelity, stronger spatial controllability, and better diagnostic consistency than existing methods.
arXiv Detail & Related papers (2026-03-11T06:14:11Z) - AS-Mamba: Asymmetric Self-Guided Mamba Decoupled Iterative Network for Metal Artifact Reduction [6.255398219368993]
Metal artifact significantly degrades Computed Tomography (CT) image quality.<n>Existing deep learning approaches, such as CNN and Transformer, often fail to explicitly capture the directional geometric features of artifacts.<n>We propose the Asymmetric Self-Guided Mamba (AS-Mamba) for metal artifact reduction.
arXiv Detail & Related papers (2026-02-06T03:27:28Z) - SIGMA: Scalable Spectral Insights for LLM Collapse [51.863164847253366]
We introduce SIGMA (Spectral Inequalities for Gram Matrix Analysis), a unified framework for model collapse.<n>By utilizing benchmarks that deriving and deterministic bounds on the matrix's spectrum, SIGMA provides a mathematically grounded metric to track the contraction of the representation space.<n>We demonstrate that SIGMA effectively captures the transition towards states, offering both theoretical insights into the mechanics of collapse.
arXiv Detail & Related papers (2026-01-06T19:47:11Z) - Physically-Grounded Manifold Projection Model for Generalizable Metal Artifact Reduction in Dental CBCT [20.637726557566793]
Metal artifacts in Dental CBCT severely obscure anatomical structures.<n>Current deep learning for Metal Artifact Reduction (MAR) faces limitations.<n>Denoising Diffusion Models (DDPMs) offer realism but rely on slow, iterative sampling.
arXiv Detail & Related papers (2025-12-30T14:36:26Z) - Solving Energy-Independent Density for CT Metal Artifact Reduction via Neural Representation [46.57879724994237]
Reconstructing CT images from metal-corrupted measurements becomes a challenging nonlinear inverse problem.<n>Existing state-of-the-art (SOTA) metal artifact reduction (MAR) algorithms rely on supervised learning with numerous paired CT samples.<n>In this work, we propose Density neural representation (Diner), a novel unsupervised MAR method.
arXiv Detail & Related papers (2024-05-11T16:30:39Z) - Gradient Descent Provably Solves Nonlinear Tomographic Reconstruction [60.95625458395291]
In computed tomography (CT) the forward model consists of a linear transform followed by an exponential nonlinearity based on the attenuation of light according to the Beer-Lambert Law.
We show that this approach reduces metal artifacts compared to a commercial reconstruction of a human skull with metal crowns.
arXiv Detail & Related papers (2023-10-06T00:47:57Z) - Unsupervised CT Metal Artifact Reduction by Plugging Diffusion Priors in
Dual Domains [8.40564813751161]
metallic implants often cause disruptive artifacts in computed tomography (CT) images, impeding accurate diagnosis.
Several supervised deep learning-based approaches have been proposed for reducing metal artifacts (MAR)
We propose an unsupervised MAR method based on the diffusion model, a generative model with a high capacity to represent data distributions.
arXiv Detail & Related papers (2023-08-31T14:00:47Z) - Unsupervised Polychromatic Neural Representation for CT Metal Artifact
Reduction [48.1445005916672]
We present a novel Polychromatic neural representation (Polyner) to tackle the challenging problem of CT imaging when metallic implants exist within the human body.
Our Polyner achieves comparable or better performance than supervised methods on in-domain datasets.
arXiv Detail & Related papers (2023-06-27T04:50:58Z) - Orientation-Shared Convolution Representation for CT Metal Artifact
Learning [63.67718355820655]
During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts.
Existing deep-learning-based methods have gained promising reconstruction performance.
We propose an orientation-shared convolution representation strategy to adapt the physical prior structures of artifacts.
arXiv Detail & Related papers (2022-12-26T13:56:12Z) - Predicting failure characteristics of structural materials via deep
learning based on nondestructive void topology [0.5735035463793008]
We report a novel method for predicting material failure characteristics that combines nondestructive X-ray computed tomography (X-CT), persistent homology (PH), and deep multimodal learning (DML)
The method exploits the microstructural defect state at the time of material examination as an input, and outputs the failure-related properties.
arXiv Detail & Related papers (2022-05-17T05:59:42Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.