- Title: FOUND-AF: Benchmarking ECG Foundation Models for Atrial Fibrillation Detection
- Abstract summary: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is associated with increased risks of stroke, heart failure, and mortality.<n>Recent ECG foundation models offer transferable representations for automated AF detection.<n>This study presents FOUND-AF, a unified, leakage-controlled, and deployment-oriented benchmarking framework that evaluates the quality of pretrained ECG representations.
- Score: 5.65079592827682
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is associated with increased risks of stroke, heart failure, and mortality. Recent ECG foundation models offer transferable representations for automated AF detection. However, their relative effectiveness remains unclear because existing studies use different datasets, preprocessing procedures, classifiers, and validation protocols. This study presents FOUND-AF, a unified, leakage-controlled, and deployment-oriented benchmarking framework that evaluates the quality of pretrained ECG representations under identical experimental conditions. Nine publicly available foundation models from five families, including HuBERT-ECG, CLEF, ST-MEM, ECG-JEPA, and ECGFounder, were evaluated across four heterogeneous ECG datasets, namely AFDB, CinC2017, CPSC2021, and LTAFDB. All models were used as frozen feature extractors with standardized preprocessing, model-native resampling, a fixed XGBoost classifier, and recording-level grouped cross-validation. The evaluation included classification metrics, receiver operating characteristic analysis, paired recording-level bootstrap comparisons with Holm correction, embedding-space visualization, and computational efficiency profiling. The ECGFounder model consistently achieved the strongest overall performance across datasets while offering a favorable trade-off between accuracy, model size, inference time, and memory usage. FOUND-AF therefore provides a reproducible framework for selecting ECG foundation models and demonstrates that compact, clinically pretrained encoders can support robust and computationally efficient AF detection across heterogeneous acquisition settings.
Related papers
- Domain-Adapted Fine-Tuning of ECG Foundation Models for Multi-Label Structural Heart Disease Screening [9.031528782284935]
We evaluated whether open pretrained electrocardiogram (ECG) foundation models can support echo-confirmed multi-label structural heart disease detection.<n>We compared engineered ECG features with gradient boosting, end-to-end waveform learning from scratch, and transfer from open ECG foundation models.<n>Adapted ECG-FM models achieved the best overall performance.
arXiv Detail & Related papers (2026-04-25T17:27:42Z) - Demographic-Aware Self-Supervised Anomaly Detection Pretraining for Equitable Rare Cardiac Diagnosis [45.00216485193071]
Rare cardiac anomalies are difficult to detect from electrocardiograms due to their long-tailed distribution.<n>We developed an AI-assisted two-stage ECG framework integrating self-supervised anomaly detection and demographic-aware representation learning.<n>Our method achieves an AUROC of 94.7% for rare anomalies and reduces the common-rare performance gap by 73%.
arXiv Detail & Related papers (2026-03-20T07:04:00Z) - CLEF: Clinically-Guided Contrastive Learning for Electrocardiogram Foundation Models [13.613519337591507]
Single-lead ECG recording is integrated into both clinical-grade and consumer wearables.<n>While self-supervised pretraining of foundation models on unlabeled ECGs improves diagnostic performance, existing approaches do not incorporate domain knowledge from clinical metadata.<n>We introduce a novel contrastive learning approach that utilizes an established clinical risk score to adaptively weight negative pairs.
arXiv Detail & Related papers (2025-12-01T20:21:44Z) - Enhancing ECG Classification Robustness with Lightweight Unsupervised Anomaly Detection Filters [39.9470953186283]
Continuous electrocardiogram (ECG) monitoring via wearables offers significant potential for early cardiovascular disease (CVD) detection.<n> deploying deep learning models for automated analysis in resource-constrained environments faces reliability challenges due to Out-of-Distribution data.<n>This paper explores Unsupervised Anomaly Detection (UAD) as an independent, upstream filtering mechanism to improve robustness.
arXiv Detail & Related papers (2025-10-30T13:54:37Z) - An Attention-Augmented VAE-BiLSTM Framework for Anomaly Detection in 12-Lead ECG Signals [0.0]
Anomaly detection in 12-lead electrocardiograms (ECGs) is critical for identifying deviations associated with cardiovascular disease.<n>To the best of our knowledge, this study reports the first application of a VAE-BiLSTM-MHA architecture to ECG anomaly detection.
arXiv Detail & Related papers (2025-10-07T13:30:02Z) - rECGnition_v2.0: Self-Attentive Canonical Fusion of ECG and Patient Data using deep learning for effective Cardiac Diagnostics [0.56337958460022]
This study uses MIT-BIH Arrhythmia dataset to evaluate the efficiency of rECGnition_v2.0 for various classes of arrhythmias.<n>The compact architectural footprint of the rECGnition_v2.0, characterized by its lesser trainable parameters, unfurled several advantages including interpretability and scalability.
arXiv Detail & Related papers (2025-02-22T15:16:46Z) - ECG-FM: An Open Electrocardiogram Foundation Model [3.8270632390229777]
We present ECG-FM, an open foundation model for ECG analysis, and conduct a study using a dataset of 1.5 million ECGs.<n>ECG-FM is a transformer-based model pretrained using a hybrid contrastive and generative self-supervised learning approach.<n>We affirm that ECG-FM is robust, label-efficient, and functionally discriminative by showcasing data scaling experiments, performing a latent space analysis, and generating saliency maps.
arXiv Detail & Related papers (2024-08-09T17:06:49Z) - SQUWA: Signal Quality Aware DNN Architecture for Enhanced Accuracy in Atrial Fibrillation Detection from Noisy PPG Signals [37.788535094404644]
Atrial fibrillation (AF) significantly increases the risk of stroke, heart disease, and mortality.
Photoplethysmography ( PPG) signals are susceptible to corruption from motion artifacts and other factors often encountered in ambulatory settings.
We propose a novel deep learning model, designed to learn how to retain accurate predictions from partially corrupted PPG.
arXiv Detail & Related papers (2024-04-15T01:07:08Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - SEVGGNet-LSTM: a fused deep learning model for ECG classification [38.747030782394646]
The input ECG signals are firstly segmented and normalized, and then fed into the combined VGG and LSTM network for feature extraction and classification.
An attention mechanism (SE block) is embedded into the core network for increasing the weight of important features.
arXiv Detail & Related papers (2022-10-31T07:36:48Z) - ECG-DelNet: Delineation of Ambulatory Electrocardiograms with Mixed
Quality Labeling Using Neural Networks [69.25956542388653]
Deep learning (DL) algorithms are gaining weight in academic and industrial settings.
We demonstrate DL can be successfully applied to low interpretative tasks by embedding ECG detection and delineation onto a segmentation framework.
The model was trained using PhysioNet's QT database, comprised of 105 ambulatory ECG recordings.