CFD-Guided Detection of Concept Drift in Multimodal Physiologic Signals
- URL: http://arxiv.org/abs/2608.07759v1
- Date: Fri, 07 Aug 2026 20:48:49 GMT
- Title: CFD-Guided Detection of Concept Drift in Multimodal Physiologic Signals
- Abstract summary: Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration.<n>This paper asks when a model should keep its prediction, change it, or flag uncertainty.<n>We propose a physiologic stability framework, called PECS, that compares changes inside the model with measurable changes in the signal.
- Score: 0.7739635712759623
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration. This paper asks when a model should keep its prediction, change it, or flag uncertainty. We propose a physiologic stability framework, called PECS, that compares changes inside the model with measurable changes in the signal. ECG is treated as the main cardiac signal, photoplethysmography (PPG) adds pulse and vascular information, and respiration is used only when ECG and PPG disagree. We test the framework on PTB-XL at pilot and full scales and on synchronized BIDMC and MIMIC waveform cohorts. The PTB-XL pilot and full- scale analyses selected different domain pairs, and the strongest cross-modal pair also changed across BIDMC and MIMIC, showing that adding every available signal is not always the best choice. PECS outperformed the evaluated drift-detection baseline implementations, reaching drift classification accuracy (DCA) of 0.8786 on expanded BIDMC and 0.9560 on MIMIC. The MIMIC results also showed that respiration can help during disagreement cases, but it should be used selectively rather than as an automatic override. Overall, the results support PECS as a candidate monitoring framework for wearable cardiovascular AI while highlighting the need for scale-aware domain selection and interpretable trust routing
Related papers
- Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU [44.313512671851306]
False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units.<n>We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task.
arXiv Detail & Related papers (2026-09-08T16:33:07Z) - Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency [23.899678708493088]
Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time.<n>We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift.
arXiv Detail & Related papers (2026-08-24T14:59:27Z) - Motif-based morphology signatures for interpretable ECG screening and monitoring [0.2578242050187029]
We propose a motif-based framework that defines beat-aligned ECG motifs as interpretable cardiac signatures.<n>We introduce three interpretable drift metrics: deviation from a normal sinus rhythm, deviation from a personalised baseline, and a motif instability index.<n>We evaluate these metrics on short (PTB-XL) and long-duration (MIT-BIH Arrhythmia) ECG datasets.
arXiv Detail & Related papers (2026-05-26T16:15:07Z) - Domain-Adaptive Arrhythmia Classification Using a Hybrid Transformer on Wearable Heart Signals [0.8594140167290097]
We propose a hybrid transformer model that processes continuous ECG signals alongside seven heart rate variability (HRV) features.<n>We employ representation learning techniques, including Maximum Mean Discrepancy (MMD), to align feature distributions between source and target domains.<n>When tested on wearable device data with an unseen domain, the model achieved an F1-macro 95% and balanced accuracy of 96.15%.
arXiv Detail & Related papers (2026-05-05T22:03:48Z) - ECG-IMN: Interpretable Mesomorphic Neural Networks for 12-Lead Electrocardiogram Interpretation [1.7152890789230053]
Deep learning has achieved expert-level performance in automated electrocardiogram (ECG) diagnosis, yet the "black-box" nature of these models hinders their clinical deployment.<n>We propose the ECG-IMN, an Interpretable Mesomorphic Neural Network tailored for high-resolution 12-lead ECG classification.
arXiv Detail & Related papers (2026-02-10T09:17:29Z) - Calibration-Free EEG-based Driver Drowsiness Detection with Online Test-Time Adaptation [43.83587667787693]
Drowsy driving is a growing cause of traffic accidents, prompting recent exploration of electroencephalography (EEG)-based drowsiness detection systems.<n>In particular, the inter-subject variability of EEG signals leads to a domain shift problem, which makes it challenging to generalize drowsiness detection models to unseen target subjects.<n>We propose a novel driver drowsiness detection framework that leverages online test-time adaptation methods to dynamically adjust to target subject distributions.
arXiv Detail & Related papers (2025-11-27T02:27:10Z) - FoundationalECGNet: A Lightweight Foundational Model for ECG-based Multitask Cardiac Analysis [1.1666234644810893]
FoundationalECGNet is a foundational framework for automated ECG classification.<n>It first distinguishes between Normal and Abnormal ECG signals, and then classifies the Abnormal signals into one of five cardiac conditions.<n>It shows state-of-the-art performance in multi-class disease detection, including a 99% F1-score for Conduction Disorders and Hypertrophy.
arXiv Detail & Related papers (2025-09-10T19:48:07Z) - Versatile Cardiovascular Signal Generation with a Unified Diffusion Transformer [41.095491708125515]
We propose UniCardio, a multi-modal diffusion transformer that reconstructs low-quality signals and synthesizes unrecorded signals.<n>By exploiting the complementary nature of cardiovascular signals, UniCardio clearly outperforms recent task-specific baselines in signal denoising, imputation, and translation.<n>These advantages position UniCardio as a promising avenue for advancing AI-assisted healthcare.
arXiv Detail & Related papers (2025-05-28T12:45:39Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [46.36100528165335]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - KaLDeX: Kalman Filter based Linear Deformable Cross Attention for Retina Vessel Segmentation [46.57880203321858]
We propose a novel network (KaLDeX) for vascular segmentation leveraging a Kalman filter based linear deformable cross attention (LDCA) module.
Our approach is based on two key components: Kalman filter (KF) based linear deformable convolution (LD) and cross-attention (CA) modules.
The proposed method is evaluated on retinal fundus image datasets (DRIVE, CHASE_BD1, and STARE) as well as the 3mm and 6mm of the OCTA-500 dataset.
arXiv Detail & Related papers (2024-10-28T16:00:42Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - A Graph-constrained Changepoint Detection Approach for ECG Segmentation [5.209323879611983]
We introduce a novel graph-based optimal changepoint detection (GCCD) method for reliable detection of R-peak positions without employing any preprocessing step.
Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed method achieves overall sensitivity Sen = 99.76, positive predictivity PPR = 99.68, and detection error rate DER = 0.55.
arXiv Detail & Related papers (2020-04-24T23:41:41Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.