Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue
- URL: http://arxiv.org/abs/2608.08860v2
- Date: Sun, 16 Aug 2026 17:11:28 GMT
- Title: Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue
- Abstract summary: This paper formulates thread insertion in tissue-relative coordinates.<n>A constrained MPC regulates the tip relative to that prediction.<n>A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50mm/s at 2.1um lateral placement error.
- Score: 3.1147891075060095
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Flexible neural electrode threads must be placed at a prescribed depth while the cortical surface moves with cardiac and respiratory pulsation. A controller tracking a fixed point in the laboratory frame cannot distinguish commanded insertion from tissue motion; the error appears as both a depth offset and relative tip--tissue velocity during contact. This paper formulates thread insertion in tissue-relative coordinates: a harmonic observer predicts delayed cortical-surface motion over the control horizon, a constrained MPC regulates the tip relative to that prediction while limiting actuator effort and lateral relative velocity, and an augmented disturbance state removes the steady offset from persistent contact force and model mismatch. In a 1-DOF MuJoCo benchmark, the controller reaches RMS relative-placement errors of 12.0\um\ free-space and 1.9\um\ in contact, versus 18.3/176.8\um\ for delayed-feedback impedance and 286.1/275.5\um\ for laboratory-frame PD -- the lower contact offset costs more peak contact force (3.43 vs.\ 2.00~mN), since it drives to commanded depth rather than yielding to tissue. A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50~mm/s at 2.1\um\ lateral placement error, and a feasibility-restoring soft-slack formulation keeps the shear constraint solvable under degraded sensing where a matched hard-constraint controller fails. A two-vertex Lyapunov certificate for the finite-horizon gain holds over $-40\%/{+}50\%$ reflected-mass mismatch, and the 1-DOF QP solves in under 0.4~ms at the 95th percentile. These results are a simulation-based control benchmark, not a clinical safety claim: the modeled tip is a rigid contact point, and flexible-thread mechanics, a validated force constraint, biological damage thresholds, and hardware-realistic sensing and timing remain necessary before deployment.
Related papers
- Beyond Control Points: Arcsecond Relative-Motion Estimation of Vision Measurement Platforms With Incomplete or Absent Control Fields [43.43572961146893]
We develop a control-adaptive differential framework that estimates platform motion directly from image displacements and known 3D points.<n>We derive the rotation observability condition, a leakage bound for unmodeled translation and nonrigid point motion, and the single-point axial-prior bias law.
arXiv Detail & Related papers (2026-08-14T03:41:30Z) - Uncertainty-guided active learning for surrogate prediction of stream-finishing wear fields [37.82552353322716]
We present an uncertainty-guided surrogate framework that predicts, directly from geometry, the three fields governing erosion.<n>The surrogate employs a deep ensemble whose disagreement estimates uncertainty, enabling an active-learning strategy that performs DEM simulations for the most uncertain orientations.
arXiv Detail & Related papers (2026-08-01T11:12:39Z) - Interaction Dynamics Modeling and Predictive Control for Safe Steerable Catheter--Tissue Interaction [0.0]
We formulate catheter--tissue interaction dynamics in the tip-normal coordinate of a single-segment single-tendon catheter.<n>A predictive inertia regulates this interaction state subject to hard contact-force, tendon-force, and constraints.<n>We show that offset-free motion regulation and contact-force safety are coupled interaction-dynamics objectives.
arXiv Detail & Related papers (2026-07-23T05:32:48Z) - A Model-Based Decoupling Strategy for Proprioception and Contact Sensing in an Architected Soft Manipulator [49.225033144914214]
We present a model-based strategy that decouples proprioceptive and contact signals from fluidic pressure sensors embedded in a soft architected segment.<n>On a single ITH segment, this approach achieves proprioceptive shape estimation with a relative bending error of 0.11 +/- 0.02 and a contact detection rate of 97% across 178 trials.
arXiv Detail & Related papers (2026-07-17T03:03:19Z) - Identification of a Physics-Based Electrical Power Consumption Model for the Unitree G1 Humanoid Arm [41.90412270641482]
This letter presents a physics-based, linear-in- parameters model for the electrical power consumption of the left arm of the UnitreeG1 humanoid robot.<n>The proposed formulation combines actuator loss terms with a baseline-torque correction that captures changes in gravity-compensation load.<n>Across 897 trajectories covering single-joint and coordinated arm motions at multiple speed levels, the identified model achieves $R2 = 0.933$ with an RMSE of 1.07 (W)
arXiv Detail & Related papers (2026-06-14T16:45:07Z) - Whole-Body Impedance Model Predictive Control for Safe Physical Human--Robot Interaction on Floating-Base Platforms [0.0]
This paper extends the authors' fixed-base two-layer Impedance MPC to floating-base platforms through a three-level architecture.<n>A contact-consistent feedback linearization reduces the arm end-effector plant to a double integrator with a emphconstant state matrix within each contact mode.<n>An Impedance Equivalence Theorem shows the infinite-horizon limit recovers a classical task-space impedance law.
arXiv Detail & Related papers (2026-06-12T16:41:20Z) - Impedance MPC with Disturbance Estimation for Dexterous Hand Control [0.0]
We present an actuator-agnostic Impedance Model Predictive Control framework for dexterous fingers.<n>On a hydraulically actuated finger, the 500,Hz Kalman MPC attains 0.5,mrad RMS, 0.1,mrad steady-state, and 6.6,mrad peak deflection.
arXiv Detail & Related papers (2026-06-12T16:28:21Z) - Impedance MPC with Patient-Torque Estimation for Knee Rehabilitation Exoskeletons [0.0]
We present an Impedance Model Predictive Control framework for knee rehabilitation exoskeletons.<n>A Kalman disturbance state driven by direct SEA-based torque sensing gives a nominal offset-free guarantee.<n>The architecture is formulated for the 20 DOF MyoSuite myoLeg via coupling-aware per-joint QPs.
arXiv Detail & Related papers (2026-06-11T15:35:03Z) - Impedance MPC for Physical Human-Robot Interaction: Predictive Disturbance Rejection with Joint-Limit Safety [0.0]
Impedance MPC with Kalman augmentation attains sub-0.05,mm steady-state error versus 44.8,mm for classical impedance.<n>On a 7-DOF Franka FR3, Impedance MPC with Kalman augmentation attains sub-0.05,mm steady-state error versus 44.8,mm for classical impedance.
arXiv Detail & Related papers (2026-06-06T18:06:25Z) - Reliable Extraction of Clinical Follow-Up Instructions: A Hybrid Neural-Symbolic Pipeline [43.0484058393522]
We test a hybrid neural-symbolic pipeline against direct generation.<n>We evaluate on a 2,000-note synthetic outpatient corpus with action-disjoint splits.
arXiv Detail & Related papers (2026-05-26T05:14:33Z) - Amplifying, Not Learning: Fine-Tuned AI Text Detectors Amplify a Pretrained Direction [51.56484100374058]
Text detectors amplify a pretrained typicality axis; they do not construct an AI-vs-human boundary.<n>On raw encoders before any task supervision, projecting onto centroid(AI)-centroid(HC3) achieves NYT-vs-HC3 AUROC 0.806/0.944/0.834 across three architectures.<n>On RoBERTa-base, raw projection exceeds fine-tuning; on RoBERTa-base, full fine-tuning reduces discrimination below raw on both fluent-formal populations tested.
arXiv Detail & Related papers (2026-05-20T19:08:38Z) - $h$-control: Training-Free Camera Control via Block-Conditional Gibbs Refinement [47.751369359301236]
textbf$h$-control attains the best FVD against all seven training-free and training-based competitors.<n>On RealEstate10K and DAVIS, textbf$h$-control attains the best FVD against all seven training-free and training-based competitors.
arXiv Detail & Related papers (2026-05-12T09:51:04Z) - Periodic Steady-State Control of a Handkerchief-Spinning Task Using a Parallel Anti-Parallelogram Tendon-driven Wrist [37.0667004392926]
We develop an intuitive dexterous wrist based on a parallel anti-parallelogram tendon-driven structure.<n>We then develop a particle-spring model of the handkerchief for control-oriented abstraction and strategy evaluation.<n>Results demonstrate that integrating control-oriented modeling with a task-tailored dexterous wrist enables robust rest-to-steady-state transitions.
arXiv Detail & Related papers (2026-04-20T06:21:12Z) - Benchmarking IoT Time-Series AD with Event-Level Augmentations [34.864214444544565]
We introduce an evaluation protocol with unified event-level augmentations that simulate real-world issues.<n>We evaluate 14 representative models on five public anomaly datasets.
arXiv Detail & Related papers (2026-02-17T09:45:44Z) - An Autonomous, End-to-End, Convex-Based Framework for Close-Range Rendezvous Trajectory Design and Guidance with Hardware Testbed Validation [3.551661404820989]
This paper presents CORTEX, an autonomous, perception-enabled, real-time trajectory design and guidance framework for close-range rendezvous.<n> CORTEX is validated in high-fidelity software simulation and hardware-in-the-loop experiments.
arXiv Detail & Related papers (2026-02-12T21:23:21Z) - Verifying Closed-Loop Contractivity of Learning-Based Controllers via Partitioning [52.23804865017831]
We address the problem of verifying closed-loop contraction in nonlinear control systems whose controller and contraction metric are both parameterized by neural networks.<n>We derive a tractable and scalable sufficient condition for closed-loop contractivity that reduces to checking that the dominant eigenvalue of a symmetric Metzler matrix is nonpositive.
arXiv Detail & Related papers (2025-12-01T23:06:56Z) - PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurement [63.007237197267834]
Existing deep learning methods are mostly physiological monitoring and lack theoretical robustness.<n>We propose a physics-informed r paradigm derived from the Navier-Stokes equations of hemodynamics, showing that the pulse signal follows a second-order system.<n>This provides a theoretical justification for using a Temporal Conal Network (TCN)<n>Phase-Net achieves state-of-the-art performance with strong efficiency, offering a theoretically grounded and deployment-ready r solution.
arXiv Detail & Related papers (2025-09-29T14:36:45Z) - Optimal control of a nitrogen-vacancy spin ensemble in diamond for
sensing in the pulsed domain [52.77024349608834]
Defects in solid state materials provide an ideal platform for quantum sensing.
Control of such an ensemble is challenging due to the spatial variation in both the defect energy levels and in any control field across a macroscopic sample.
We experimentally demonstrate that we can overcome these challenges using Floquet theory and optimal control optimization methods.
arXiv Detail & Related papers (2021-01-25T13:01:05Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.