Impedance MPC with Patient-Torque Estimation for Knee Rehabilitation Exoskeletons
- URL: http://arxiv.org/abs/2606.13485v1
- Date: Thu, 11 Jun 2026 15:35:03 GMT
- Title: Impedance MPC with Patient-Torque Estimation for Knee Rehabilitation Exoskeletons
- Abstract summary: We present an Impedance Model Predictive Control framework for knee rehabilitation exoskeletons.<n>A Kalman disturbance state driven by direct SEA-based torque sensing gives a nominal offset-free guarantee.<n>The architecture is formulated for the 20 DOF MyoSuite myoLeg via coupling-aware per-joint QPs.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Knee rehabilitation exoskeletons must enforce a prescribed joint trajectory while remaining safely compliant with involuntary spasm and voluntary patient effort-objectives in tension for any fixed-gain impedance controller. We present an Impedance Model Predictive Control framework for knee rehabilitation exoskeletons, demonstrated on a series-elastic-actuator (SEA) platform: an algebraic feedforward reduces the knee dynamics to a constant-coefficient scalar double integrator, and a receding-horizon quadratic program (QP) computes corrective torques while enforcing hard range-of-motion, torque, and velocity limits (ISO 13482). A Kalman disturbance state driven by direct SEA-based torque sensing (the series-elastic spring deflection measured through the elastic element - an intrinsic, EMG-free patient-torque estimate, not a separate load cell) gives a nominal offset-free guarantee and, via its sign and the desired-motion direction, sensorless Assist-as-Needed. The constant state matrix permits offline precomputation of the QP cost inverse, enabling 500 Hz operation with a multi-step horizon. Across seven-controller benchmarks (sinusoidal tracking, isometric hold), the 500 Hz Kalman MPC is offset free 0.1 mrad RMS, 0.1 mrad steady-state, 0.2 mrad peak under 15 Nm spasm, versus a 515 mrad steady-state offset for classical impedance at the same stiffness - the direct-measurement channel converging the estimate near-immediately (within a few sampling periods). Without the estimator it realizes a classical impedance (4.8 mrad RMS, 8.3 mrad steady-state). All MPC variants meet the 87 mrad clinical criterion; no classical controller does. The architecture is formulated for the 20 DOF MyoSuite myoLeg via coupling-aware per-joint QPs.
Related papers
- Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue [3.1147891075060095]
This paper formulates thread insertion in tissue-relative coordinates.<n>A constrained MPC regulates the tip relative to that prediction.<n>A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50mm/s at 2.1um lateral placement error.
arXiv Detail & Related papers (2026-08-09T18:53:32Z) - Interaction Dynamics Modeling and Predictive Control for Safe Steerable Catheter--Tissue Interaction [0.0]
We formulate catheter--tissue interaction dynamics in the tip-normal coordinate of a single-segment single-tendon catheter.<n>A predictive inertia regulates this interaction state subject to hard contact-force, tendon-force, and constraints.<n>We show that offset-free motion regulation and contact-force safety are coupled interaction-dynamics objectives.
arXiv Detail & Related papers (2026-07-23T05:32:48Z) - ActiveVital: Geometry-Aware Embodied Vital Signs Monitoring for Home Healthcare Robots [29.28450135227186]
Home robots require reliable vital signs monitoring to support long-term companionship and safety in daily environments.<n>Millimeter-wave (mmWave) radar offers a promising solution due to its phase sensitivity to sub-millimeter motions.<n>We propose ActiveVital, a vision-guided sensing framework that treats sensing geometry as an explicit control variable for robots.
arXiv Detail & Related papers (2026-06-29T13:22:13Z) - Friction Characterization of a Cable-Driven Differential Actuation System for Lower-Limb Exoskeletons [42.628421392139]
Lower-limb exoskeletons require actuation systems that can provide accurate joint torque control.<n> Conventional architectures often rely on independently actuated joints and joint-level torque sensors.<n>This paper presents a novel differential actuation architecture for hip-knee flexion/extension.
arXiv Detail & Related papers (2026-06-14T19:47:32Z) - Identification of a Physics-Based Electrical Power Consumption Model for the Unitree G1 Humanoid Arm [41.90412270641482]
This letter presents a physics-based, linear-in- parameters model for the electrical power consumption of the left arm of the UnitreeG1 humanoid robot.<n>The proposed formulation combines actuator loss terms with a baseline-torque correction that captures changes in gravity-compensation load.<n>Across 897 trajectories covering single-joint and coordinated arm motions at multiple speed levels, the identified model achieves $R2 = 0.933$ with an RMSE of 1.07 (W)
arXiv Detail & Related papers (2026-06-14T16:45:07Z) - Whole-Body Impedance Model Predictive Control for Safe Physical Human--Robot Interaction on Floating-Base Platforms [0.0]
This paper extends the authors' fixed-base two-layer Impedance MPC to floating-base platforms through a three-level architecture.<n>A contact-consistent feedback linearization reduces the arm end-effector plant to a double integrator with a emphconstant state matrix within each contact mode.<n>An Impedance Equivalence Theorem shows the infinite-horizon limit recovers a classical task-space impedance law.
arXiv Detail & Related papers (2026-06-12T16:41:20Z) - Impedance MPC with Disturbance Estimation for Dexterous Hand Control [0.0]
We present an actuator-agnostic Impedance Model Predictive Control framework for dexterous fingers.<n>On a hydraulically actuated finger, the 500,Hz Kalman MPC attains 0.5,mrad RMS, 0.1,mrad steady-state, and 6.6,mrad peak deflection.
arXiv Detail & Related papers (2026-06-12T16:28:21Z) - Impedance MPC for Physical Human-Robot Interaction: Predictive Disturbance Rejection with Joint-Limit Safety [0.0]
Impedance MPC with Kalman augmentation attains sub-0.05,mm steady-state error versus 44.8,mm for classical impedance.<n>On a 7-DOF Franka FR3, Impedance MPC with Kalman augmentation attains sub-0.05,mm steady-state error versus 44.8,mm for classical impedance.
arXiv Detail & Related papers (2026-06-06T18:06:25Z) - End-to-End Control of a Powered Knee-Ankle Prosthesis Towards Unified, Tuning-Free Assistance [1.7837718124568467]
We present real-time deployment of an end-to-end prosthesis controller that estimates continuous actuator signals from onboard sensors.<n>Temporal Convolutional Networks were trained on a multi-terrain dataset from 18 individuals with transfemoral amputation.
arXiv Detail & Related papers (2026-06-05T23:24:21Z) - Investigating the Effect of a Series Elastic Actuation Retrofit to Black-Box Actuators [32.56662401912643]
Series Elastic Actuation (SEA) introduces compliance to enhance disturbance rejection.<n>It enables force measurement via Hooke's Law but reduces system bandwidth.<n>The module increased bandwidth from 10.32 Hz to 30.32 Hz, a 2.93X improvement.
arXiv Detail & Related papers (2026-05-22T18:41:12Z) - Gated QKAN-FWP: Scalable Quantum-inspired Sequence Learning [38.502127166117674]
We propose gated QKAN-FWP, a fast-weight framework that integrates FWP with Quantum-inspired Kolmogorov-Arnold Network (QKAN)<n>We use single-qubit data re-uploading circuits as learnable nonlinear activation, known as DatA Re-Uploading ActivatioN (DARUAN)<n>We evaluate the framework across time-series benchmarks, MiniGrid reinforcement learning, and highlight real-world solar cycle forecasting as our main practical result.
arXiv Detail & Related papers (2026-05-07T13:04:09Z) - Beyond Prompt: Fine-grained Simulation of Cognitively Impaired Standardized Patients via Stochastic Steering [58.85421622061983]
We propose StsPatient for the fine-grained simulation of cognitively impaired patients.<n>We capture domain-specific features by extracting steering vectors from contrastive pairs of instructions and responses.<n>StsPatient significantly outperforms baselines in both clinical authenticity and severity controllability.
arXiv Detail & Related papers (2026-04-14T02:37:46Z) - A Novel Hybrid PID-LQR Controller for Sit-To-Stand Assistance Using a CAD-Integrated Simscape Multibody Lower Limb Exoskeleton [1.441595027675735]
Precise control of lower limb exoskeletons during sit-to-stand transitions remains a central challenge in robotics.<n>This paper presents the systematic, simulation, and comparative evaluation of three control strategies.
arXiv Detail & Related papers (2026-04-04T15:37:11Z) - CT-Enabled Patient-Specific Simulation and Contact-Aware Robotic Planning for Cochlear Implantation [41.386729124620366]
Robotic cochlear-implant insertion requires precise prediction and regulation of contact forces to minimize intracochlear trauma.<n>This paper presents a unified CT-to-simulation pipeline for contact-aware insertion planning and validation.
arXiv Detail & Related papers (2026-03-05T16:13:59Z) - Suppressing Prior-Comparison Hallucinations in Radiology Report Generation via Semantically Decoupled Latent Steering [94.37535002230504]
We develop a training-free, inference-time control framework termed Semantically Decoupled Latent Steering.<n>Our approach constructs a semantic-free intervention vector via large language model (LLM)-driven semantic decomposition.<n>We show that our approach significantly reduces the probability of historical hallucinations.
arXiv Detail & Related papers (2026-02-27T04:49:01Z) - Transparent Early ICU Mortality Prediction with Clinical Transformer and Per-Case Modality Attribution [42.85462513661566]
We present a lightweight, transparent multimodal ensemble that fuses physiological time-series measurements with unstructured clinical notes from the first 48 hours of an ICU stay.<n>A logistic regression model combines predictions from two modality-specific models: a bidirectional LSTM for vitals and a finetuned ClinicalModernBERT transformer for notes.<n>On the MIMIC-III benchmark, our late-fusion ensemble improves discrimination over the best single model while maintaining well-calibrated predictions.
arXiv Detail & Related papers (2025-11-19T20:11:49Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.