Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction
- URL: http://arxiv.org/abs/2608.10170v1
- Date: Mon, 10 Aug 2026 19:37:31 GMT
- Title: Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction
- Abstract summary: We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction.<n>On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%.<n>On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity.
- Score: 5.935221658266667
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
Related papers
- Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts [56.74856091904914]
We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction.<n>ScanCLIP derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features.<n>A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction.
arXiv Detail & Related papers (2026-05-29T02:48:23Z) - D3Seg: Dependency-Aware Diffusion for Brain Tumor Segmentation with Missing Modalities [54.87947751720332]
We propose a novel segmentation model D3Seg to maintain stable performance under missing-modality settings.<n>The proposed model achieves approximately 1.5-2.0% Dice improvement on enhancing tumor (ET) and around 1.0% on tumor core (TC) across multiple missing modality configurations.
arXiv Detail & Related papers (2026-05-21T09:55:42Z) - MotionDPS: Motion-Compensated 3D Brain MRI Reconstruction [39.243053176227065]
We propose a motion-compensated 3D MRI that estimates the anatomical image, rigid-body motion parameters, and coil sensitivity maps directly from motion-corrupted k-space data.<n>Our approach integrates pretrained 3D complex-valued score-based diffusion models as expressive anatomical image priors within a physics-based forward model.<n> Experiments on simulated and real-motion brain MRI datasets demonstrate that the proposed method achieves improved image quality and motion robustness.
arXiv Detail & Related papers (2026-05-21T07:53:06Z) - Degradation-Aware Blur-Segmentation of Brain Tumor [6.772154747032075]
Degradation-Aware Blur-Segmentation Net (DABSeg) is a synchronous deblurring 3D multimodal MRI segmentation network.<n>We propose a feature-domain motion-deblurring stem to compensate for blur and rebalance intensity.<n>System embeds a blur-aware cross-modal cross-attention module and multi-scale residual aggregation to yield effective modality complementarity.
arXiv Detail & Related papers (2026-05-15T06:47:37Z) - AI Approach for MRI-only Full-Spine Vertebral Segmentation and 3D Reconstruction in Paediatric Scoliosis [0.0]
MRI is preferred over CT in paediatric imaging because it avoids ionising radiation.<n>Its use in spine deformity assessment is largely limited by the lack of automated, high-resolution 3D bony reconstruction.<n>This study introduces an AI framework that enables fully automated thoracolumbar spine (T1-L5) segmentation and 3D reconstruction from MRI alone.
arXiv Detail & Related papers (2026-04-20T05:57:06Z) - FDP: A Frequency-Decomposition Preprocessing Pipeline for Unsupervised Anomaly Detection in Brain MRI [44.4791295950757]
We develop an unsupervised anomaly detection (UAD) approach for brain MRI.<n>We conduct the first systematic frequency-domain analysis of pathological signatures.<n>We show that Frequency-Decomposition Preprocessing (FDP) framework can leverage frequency-domain reconstruction for simultaneous pathology suppression and anatomical preservation.
arXiv Detail & Related papers (2025-11-17T02:40:14Z) - Estimation of Head Motion in Structural MRI and its Impact on Cortical Thickness Measurements in Retrospective Data [4.072070248526498]
Motion-related artifacts are inevitable in Magnetic Resonance Imaging (MRI)<n>These artifacts can bias automated neuroanatomical metrics such as cortical thickness.<n>Here, we train a 3D convolutional neural network to estimate a summary motion metric in retrospective routine research scans.
arXiv Detail & Related papers (2025-05-29T18:08:59Z) - DIMA: DIffusing Motion Artifacts for unsupervised correction in brain MRI images [4.117232425638352]
DIMA (DIffusing Motion Artifacts) is a novel framework that leverages diffusion models to enable unsupervised motion artifact correction in brain MRI.<n>Our two-phase approach first trains a diffusion model on unpaired motion-affected images to learn the distribution of motion artifacts.<n>This model then generates realistic motion artifacts on clean images, creating paired datasets suitable for supervised training of correction networks.
arXiv Detail & Related papers (2025-04-09T10:43:38Z) - 3D Vessel Reconstruction from Sparse-View Dynamic DSA Images via Vessel Probability Guided Attenuation Learning [79.60829508459753]
Current commercial Digital Subtraction Angiography (DSA) systems typically demand hundreds of scanning views to perform reconstruction.
The dynamic blood flow and insufficient input of sparse-view DSA images present significant challenges to the 3D vessel reconstruction task.
We propose to use a time-agnostic vessel probability field to solve this problem effectively.
arXiv Detail & Related papers (2024-05-17T11:23:33Z) - A self-attention model for robust rigid slice-to-volume registration of functional MRI [4.615338063719135]
Head motion during fMRI scans can result in distortion, biased analyses, and increased costs.
We introduce an end-to-end SVR model for aligning 2D fMRI slices with a 3D reference volume.
Our model achieves competitive performance in terms of alignment accuracy compared to state-of-the-art deep learning-based methods.
arXiv Detail & Related papers (2024-04-06T08:02:18Z) - Rotational Augmented Noise2Inverse for Low-dose Computed Tomography
Reconstruction [83.73429628413773]
Supervised deep learning methods have shown the ability to remove noise in images but require accurate ground truth.
We propose a novel self-supervised framework for LDCT, in which ground truth is not required for training the convolutional neural network (CNN)
Numerical and experimental results show that the reconstruction accuracy of N2I with sparse views is degrading while the proposed rotational augmented Noise2Inverse (RAN2I) method keeps better image quality over a different range of sampling angles.
arXiv Detail & Related papers (2023-12-19T22:40:51Z) - Automated SSIM Regression for Detection and Quantification of Motion
Artefacts in Brain MR Images [54.739076152240024]
Motion artefacts in magnetic resonance brain images are a crucial issue.
The assessment of MR image quality is fundamental before proceeding with the clinical diagnosis.
An automated image quality assessment based on the structural similarity index (SSIM) regression has been proposed here.
arXiv Detail & Related papers (2022-06-14T10:16:54Z) - Negligible effect of brain MRI data preprocessing for tumor segmentation [36.89606202543839]
We conduct experiments on three publicly available datasets and evaluate the effect of different preprocessing steps in deep neural networks.
Our results demonstrate that most popular standardization steps add no value to the network performance.
We suggest that image intensity normalization approaches do not contribute to model accuracy because of the reduction of signal variance with image standardization.
arXiv Detail & Related papers (2022-04-11T17:29:36Z)