SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI
- URL: http://arxiv.org/abs/2608.18616v1
- Date: Wed, 19 Aug 2026 07:07:33 GMT
- Title: SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI
- Abstract summary: Reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion.<n>We present the pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal thoracic ultrasound) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for segmentation and anatomical reorientation.
- Score: 0.2793066653220178
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.
Related papers
- AI Approach for MRI-only Full-Spine Vertebral Segmentation and 3D Reconstruction in Paediatric Scoliosis [0.0]
MRI is preferred over CT in paediatric imaging because it avoids ionising radiation.<n>Its use in spine deformity assessment is largely limited by the lack of automated, high-resolution 3D bony reconstruction.<n>This study introduces an AI framework that enables fully automated thoracolumbar spine (T1-L5) segmentation and 3D reconstruction from MRI alone.
arXiv Detail & Related papers (2026-04-20T05:57:06Z) - ConvFormer3D-TAP: Phase/Uncertainty-Aware Front-End Fusion for Cine CMR View Classification Pipelines [0.879504058268139]
ConvFormer3D-TAP integrates 3D convolutional tokenization with multiscale self-attention to enhance robustness across cardiac phases and ambiguous temporal segments.<n>On a cohort of 150,974 clinically acquired cine sequences, ConvFormer3D- achieved 96% validation accuracy with per-class F1-scores.<n>These results support ConvFormer3DTAP as a scalable front-end for view routing, filtering and quality control in end-to-end cMRI.
arXiv Detail & Related papers (2026-04-13T12:29:16Z) - Synthesizing Accurate and Realistic T1-weighted Contrast-Enhanced MR Images using Posterior-Mean Rectified Flow [3.024548464833694]
Contrast-enhanced (CE) T1-weighted MRI is central to neuro-oncologic diagnosis but requires gadolinium-based agents.<n>We propose a two-stage Posterior-Mean Rectified Flow pipeline for synthesizing CE brain MRI from non-contrast inputs.
arXiv Detail & Related papers (2025-08-18T05:55:57Z) - Robotic Ultrasound-Guided Femoral Artery Reconstruction of Anatomically-Representative Phantoms [2.1113382954657594]
Femoral artery access is essential for numerous clinical procedures, including diagnostic angiography, therapeutic catheterization, and emergency interventions.<n>Despite its critical role, successful vascular access remains challenging due to anatomical variability, overlying adipose tissue, and the need for precise ultrasound guidance.<n>We present a method for autonomous robotic US scanning of bifurcated femoral arteries, and validate it on five vascular phantoms created from real patient computed tomography (CT) data.
arXiv Detail & Related papers (2025-03-09T22:20:25Z) - A Comprehensive Framework for Automated Segmentation of Perivascular Spaces in Brain MRI with the nnU-Net [37.179674347248266]
Enlargement of perivascular spaces (PVS) is common in neurodegenerative disorders.<n>There is a need for reliable PVS detection methods which are currently lacking.
arXiv Detail & Related papers (2024-11-29T09:19:57Z) - Epicardium Prompt-guided Real-time Cardiac Ultrasound Frame-to-volume Registration [50.602074919305636]
This paper introduces a lightweight end-to-end Cardiac Ultrasound frame-to-volume Registration network, termed CU-Reg.<n>We use epicardium prompt-guided anatomical clues to reinforce the interaction of 2D sparse and 3D dense features, followed by a voxel-wise local-global aggregation of enhanced features.
arXiv Detail & Related papers (2024-06-20T17:47:30Z) - Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI [43.47826598981827]
We introduce HybridVNet, a novel architecture for direct image-to-mesh extraction.<n>We show it can efficiently handle surface and volumetric meshes by encoding them as graph structures.<n>Our model combines traditional convolutional networks with variational graph generative models, deep supervision and mesh-specific regularisation.
arXiv Detail & Related papers (2023-11-22T21:51:29Z) - Deep-learning-based acceleration of MRI for radiotherapy planning of
pediatric patients with brain tumors [39.58317527488534]
We developed a deep learning-based method for MRI reconstruction from undersampled data acquired with RT-specific receiver coil arrangements.
DeepMRIRec reduced scanning time by a factor of four producing a structural similarity score surpassing the evaluated state-of-the-art method.
arXiv Detail & Related papers (2023-11-22T16:01:44Z) - Reconstruction of Cardiac Cine MRI Using Motion-Guided Deformable Alignment and Multi-Resolution Fusion [4.828904401099519]
A novel end-to-end deep learning network is developed to improve cardiac cine MRI reconstruction.
The proposed method exhibits high-quality results with richer details and fewer artifacts for cardiac cine MRI reconstruction on different accelerations.
arXiv Detail & Related papers (2023-03-09T01:03:35Z) - A Deep Learning-Based Fully Automated Pipeline for Regurgitant Mitral Valve Anatomy Analysis From 3D Echocardiography [0.3387808070669509]
The developed approach relies on a 3D multi-decoder residual convolutional neural network (CNN) with a U-Net architecture for multi-class segmentation of MV annulus and leaflets.<n>The whole process requires minimal user interaction and requires approximately 15 seconds.
arXiv Detail & Related papers (2023-02-21T12:48:44Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z) - Segmentation of the Myocardium on Late-Gadolinium Enhanced MRI based on
2.5 D Residual Squeeze and Excitation Deep Learning Model [55.09533240649176]
The aim of this work is to develop an accurate automatic segmentation method based on deep learning models for the myocardial borders on LGE-MRI.
A total number of 320 exams (with a mean number of 6 slices per exam) were used for training and 28 exams used for testing.
The performance analysis of the proposed ensemble model in the basal and middle slices was similar as compared to intra-observer study and slightly lower at apical slices.
arXiv Detail & Related papers (2020-05-27T20:44:38Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.