Towards Investigating Residual Hearing Loss: Quantification of Fibrosis in a Novel Cochlear OCT Dataset
- URL: http://arxiv.org/abs/2608.21189v1
- Date: Fri, 21 Aug 2026 14:59:19 GMT
- Title: Towards Investigating Residual Hearing Loss: Quantification of Fibrosis in a Novel Cochlear OCT Dataset
- Abstract summary: We present the results of several state-of-the-art semantic segmentation models and compare their efficacy for identifying cochlear fibrosis.<n>For the first time, we have successfully applied computer vision techniques to an OCT dataset of implanted cochleae with fibrosis.
- Score: 11.166312525925116
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Objective: Cochlear implants (CIs) are bionic prostheses that restores hearing via electrical stimulation of the auditory nerve. Hybrid CIs, which use electroacoustic stimulation (EAS), combine residual low-frequency acoustic hearing with CI electrical stimulation. Intracochlear fibrosis, which forms in response to the presence of the implant, may impede residual hearing function and gradually reduce the efficacy of EAS. It is therefore a translational objective to study the formation of cochlear fibrosis in rodents, with the goal of reducing fibrotic burden and improving outcomes for CI patients. Methods: We generate and annotate a novel dataset of optical coherence tomography (OCT) images from chronically implanted guinea pigs as part of an ongoing study focused on implant induced fibrosis. Objectively assessing fibrotic burden in this model, with high resolution and repeatability, presents an obvious use case for computer vision methods. Results: We present the results of several state-of-the-art semantic segmentation models and compare their efficacy for identifying cochlear fibrosis and other relevant annotations, using a new library of manually segmented OCT images. Conclusions: We find that the best performance is achieved by using a modified version of the well-known UNET architecture (which we term 2D-OCT-UNET) that operates on the upscaled OCT input resolution. Significance: For the first time, we have successfully applied computer vision techniques to an OCT dataset of implanted cochleae with fibrosis. Using this deep learning model, the cochlear fibrotic burden calculation can be reliably carried out as we verify in our experimental section. The dataset and the project code are available at: https://github.com/juliadietlmeier/CF-OCT-segmentation
Related papers
- Anatomy-Aware Low-Dose CT Denoising via Pretrained Vision Models and Semantic-Guided Contrastive Learning [12.975922919920393]
We propose ALDEN, an anatomy-aware LDCT denoising method that integrates semantic features of pretrained vision models with adversarial and contrastive learning.<n>Specifically, we introduce an anatomy-aware discriminator that dynamically fuses hierarchical semantic features from reference normal-dose CT (NDCT) via cross-attention mechanisms.<n>In addition, we propose a semantic-guided contrastive learning module that enforces anatomical consistency by contrasting PVM-derived features from LDCT, denoised CT and NDCT, preserving tissue-specific patterns through positive pairs and suppressing artifacts via dual negative pairs.
arXiv Detail & Related papers (2025-08-11T09:17:12Z) - Bayesian Deep Learning Approaches for Uncertainty-Aware Retinal OCT Image Segmentation for Multiple Sclerosis [0.0]
Optical Coherence Tomography ( OCT) provides valuable insights in ophthalmology, cardiology, and neurology.<n>One critical task for ophthalmologists using OCT is delineation of retinal layers within scans.<n>Previous efforts to automate delineation using deep learning face challenges in uptake from clinicians and statisticians.
arXiv Detail & Related papers (2025-05-17T15:56:17Z) - Topology-based deep-learning segmentation method for deep anterior lamellar keratoplasty (DALK) surgical guidance using M-mode OCT data [0.0]
We develop a topology-based deep-learning segmentation method that integrates a topological loss function with a modified network architecture.<n>This approach effectively reduces the effects of noise and improves segmentation speed, precision, and stability.
arXiv Detail & Related papers (2025-01-07T19:57:15Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - Tissue Classification During Needle Insertion Using Self-Supervised
Contrastive Learning and Optical Coherence Tomography [53.38589633687604]
We propose a deep neural network that classifies the tissues from the phase and intensity data of complex OCT signals acquired at the needle tip.
We show that with 10% of the training set, our proposed pretraining strategy helps the model achieve an F1 score of 0.84 whereas the model achieves an F1 score of 0.60 without it.
arXiv Detail & Related papers (2023-04-26T14:11:04Z) - Reliable Joint Segmentation of Retinal Edema Lesions in OCT Images [55.83984261827332]
In this paper, we propose a novel reliable multi-scale wavelet-enhanced transformer network.
We develop a novel segmentation backbone that integrates a wavelet-enhanced feature extractor network and a multi-scale transformer module.
Our proposed method achieves better segmentation accuracy with a high degree of reliability as compared to other state-of-the-art segmentation approaches.
arXiv Detail & Related papers (2022-12-01T07:32:56Z) - Data-driven generation of plausible tissue geometries for realistic
photoacoustic image synthesis [53.65837038435433]
Photoacoustic tomography (PAT) has the potential to recover morphological and functional tissue properties.
We propose a novel approach to PAT data simulation, which we refer to as "learning to simulate"
We leverage the concept of Generative Adversarial Networks (GANs) trained on semantically annotated medical imaging data to generate plausible tissue geometries.
arXiv Detail & Related papers (2021-03-29T11:30:18Z) - Fibrosis-Net: A Tailored Deep Convolutional Neural Network Design for
Prediction of Pulmonary Fibrosis Progression from Chest CT Images [59.622239796473885]
Pulmonary fibrosis is a chronic lung disease that causes irreparable lung tissue scarring and damage, resulting in progressive loss in lung capacity and no known cure.
We introduce Fibrosis-Net, a deep convolutional neural network design tailored for the prediction of pulmonary fibrosis progression from chest CT images.
arXiv Detail & Related papers (2021-03-06T02:16:41Z) - Low-dimensional Manifold Constrained Disentanglement Network for Metal
Artifact Reduction [17.01644053979103]
An artifact disentanglement network (ADN) was proposed with unpaired clinical images directly, producing promising results on clinical datasets.
We propose a low-dimensional manifold (LDM) constrained disentanglement network (DN), leveraging the image characteristics that the patch manifold is generally low-dimensional.
We show that the proposed LDM-DN approach can consistently improve the MAR performance in paired and/or unpaired learning settings.
arXiv Detail & Related papers (2020-07-08T03:47:34Z) - Segmentation of Retinal Low-Cost Optical Coherence Tomography Images
using Deep Learning [2.571523045125397]
The need for treatment is determined by the presence or change of disease-specific OCT-based biomarkers.
The monitoring frequency of current treatment schemes is not individually adapted to the patient and therefore often insufficient.
One of the key requirements of a home monitoring OCT system is a computer-aided diagnosis to automatically detect and quantify pathological changes.
arXiv Detail & Related papers (2020-01-23T12:55:53Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.