Repeatability Characterisation and Error Budget of a Consumer Structured-Light Scanner for 3-D Wound Geometry:A Rigid-Phantom Study
- URL: http://arxiv.org/abs/2608.30143v1
- Date: Mon, 31 Aug 2026 01:49:51 GMT
- Title: Repeatability Characterisation and Error Budget of a Consumer Structured-Light Scanner for 3-D Wound Geometry:A Rigid-Phantom Study
- Abstract summary: We characterise the measurement error of a free- hand consumer structured-light scanner used to derive geometric wound descriptors.<n>Rigorous wound-care phantoms cannot change, so every difference between repeat scans of one site is measurement error.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: We characterise the measurement error of a free- hand consumer structured-light scanner used to derive three- dimensional geometric wound descriptors. Rigid wound-care phantoms cannot change, so every difference between repeat scans of one site is measurement error; all repeats come from a single scanner unit, nine sites and 23 scans, so this charac- terises one instrument. The 95 percent repeatability limit for reconstructed surface area is a factor of 4.8, with a confidence interval from 3.0 to 7.0, so rescanning an unchanged site can shift the reading from a 79 percent decrease to a 377 percent increase. Forty-four of 45 descriptors fall below an intraclass correlation of 0.50, and none of 248 descriptor and pipeline combinations reaches 0.75. An error budget formed by holding the analy- sis region fixed, leaving sensor and reconstruction untouched, bounds the share of variance attributable to how much surface the operator captured at 75 percent for surface area, 91 percent for hull area and 95 percent for bounding-box diagonal; only hull volume is majority instrumental, at 48 percent, so a better sensor would buy little. No wound is delineated anywhere in the chain, so the comparison against the four-week area reduction used clinically to predict healing, a ratio near 2.1, is a lower bound on the noise an unsegmented pipeline must overcome, not a measurement of wound-area reproducibility. Standardising the analysis region cuts the limit to 2.13, meeting that ratio rather than clearing it. Statistical outlier removal imposes a measured systematic area deficit near 11 percent.
Related papers
- Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring [0.6439594960617159]
DAMM-Net++ is a 2.5D architecture for thoracic radiotherapy auto-contouring.<n>It addresses inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals.<n>It achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk.
arXiv Detail & Related papers (2026-09-11T11:13:06Z) - Parameter-Efficient pretrained-CT-to-MRI Transfer for Rectal Cancer Segmentation: Performance-Calibration Trade-offs [3.0748861313822995]
We introduce SWIFT, a pretrained model wIth parameter-eF and Tumor-aware fine-tuning for rectal cancer segmentation.<n>A Swin V2 encoder pretrained on 10,444 public 3D CT volumes was adapted to T2-weighted MRI through four cumulative configurations.<n> Geometric accuracy, tumor detection, radiomic agreement, and probability calibration were evaluated.
arXiv Detail & Related papers (2026-08-27T14:27:49Z) - Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation [0.28675177318965045]
Conventional ultrasound blurs the exact boundary of the gland.<n>Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall.<n>Supervised methods are costly and generalise poorly across scanners.<n>We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images.
arXiv Detail & Related papers (2026-08-14T18:07:15Z) - RibAssist 3D: Biplanar Rib-Fracture Detection, Addressing, and Selective 3D Localization from CT-Derived Projections [0.6768558752130311]
Rib fractures are common and time-consuming to localize on computed tomography (CT)<n>We ask whether fractures detected independently in two orthogonal CT-derived projections can be paired across views and triangulated into reliable 3D points at a controlled rate of false outputs.<n>The study establishes a reproducible framework for selective 3D localization and identifies cross-view correspondence as the dominant operational bottleneck.
arXiv Detail & Related papers (2026-08-07T07:47:20Z) - Online Shift Detection and Conformal Adaptation for Deployed Safety Classifiers [0.0]
We present an online monitoring system for distributional shift in deployed safety classifiers.<n>After detection, a conformal abstention layer adapts decision to recover a target error.<n>The system achieves 86.6% detection with mean latency of 39.5800 steps.
arXiv Detail & Related papers (2026-06-10T11:24:25Z) - Amplifying, Not Learning: Fine-Tuned AI Text Detectors Amplify a Pretrained Direction [51.56484100374058]
Text detectors amplify a pretrained typicality axis; they do not construct an AI-vs-human boundary.<n>On raw encoders before any task supervision, projecting onto centroid(AI)-centroid(HC3) achieves NYT-vs-HC3 AUROC 0.806/0.944/0.834 across three architectures.<n>On RoBERTa-base, raw projection exceeds fine-tuning; on RoBERTa-base, full fine-tuning reduces discrimination below raw on both fluent-formal populations tested.
arXiv Detail & Related papers (2026-05-20T19:08:38Z) - Paired-CSLiDAR: Height-Stratified Registration for Cross-Source Aerial-Ground LiDAR Pose Refinement [46.13526676100776]
We introduce Paired-CSLiDAR, a cross-source aerial-ground LiDAR benchmark for single-scan pose refinement.<n>The benchmark contains 12,683 ground-aerial pairs across 6 evaluation sites.<n>We propose Residual-Guided Stratified Registration (RGSR), a training-free, geometry-only refinement pipeline.
arXiv Detail & Related papers (2026-05-01T13:14:20Z) - From Black Box to Glass Box: Cross-Model ASR Disagreement to Prioto Review in Ambient AI Scribe Documentation [43.148402136307716]
Cross-model disagreement among heterogeneous ASR systems can act as a reference-free uncertainty signal.<n>We transcribed 50 publicly available medical audio clips with eight ASR systems spanning commercial APIs and open-source engines.<n>Low-agreement regions were enriched for content disagreements, with the content fraction increasing from 53.9% to 73.9% across quintiles of high-risk mass.
arXiv Detail & Related papers (2026-03-02T13:02:13Z) - Deep Unsupervised Anomaly Detection in Brain Imaging: Large-Scale Benchmarking and Bias Analysis [42.60508892284938]
We present a large-scale, multi-center benchmark of deep unsupervised anomaly detection for brain imaging.<n>We tested 2,221 T1w and 1,262 T2w scans spanning healthy datasets and diverse clinical cohorts.<n>Our benchmark establishes a transparent foundation for future research and highlights priorities for clinical translation.
arXiv Detail & Related papers (2025-12-01T11:03:27Z) - Leveraging the Mahalanobis Distance to enhance Unsupervised Brain MRI Anomaly Detection [35.46541584018842]
Unsupervised Anomaly Detection (UAD) methods rely on healthy data distributions to identify anomalies as outliers.
In brain MRI, a common approach is reconstruction-based UAD, where generative models reconstruct healthy brain MRIs, and anomalies are detected as deviations between input and reconstruction.
We construct multiple reconstructions with probabilistic diffusion models. We then analyze the resulting distribution of these reconstructions using the Mahalanobis distance to identify anomalies as outliers.
arXiv Detail & Related papers (2024-07-17T11:02:31Z) - A multicenter study on radiomic features from T$_2$-weighted images of a
customized MR pelvic phantom setting the basis for robust radiomic models in
clinics [47.187609203210705]
2D and 3D T$$-weighted images of a pelvic phantom were acquired on three scanners.
repeatability and repositioning of radiomic features were assessed.
arXiv Detail & Related papers (2020-05-14T09:24:48Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.