Evaluation Principles for MRI-MRA Registration in Trigeminal Neuralgia: An ROI-Centered Neurovascular Benchmark
- URL: http://arxiv.org/abs/2609.08805v1
- Date: Tue, 08 Sep 2026 14:32:44 GMT
- Title: Evaluation Principles for MRI-MRA Registration in Trigeminal Neuralgia: An ROI-Centered Neurovascular Benchmark
- Abstract summary: We formulate TN MRI-MRA fusion as an ROI-centered neurovascular registration-evaluation problem.<n>Deformable refinement provided only a small, FOV-dependent benefit over affine alignment.<n>These findings indicate that TN MRI-MRA registration should be evaluated as a local, vessel-aware, contrast-sensitive, and FOV-aware visualization task.
- Score: 3.999936516472969
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Preoperative evaluation of trigeminal neuralgia (TN) often requires joint interpretation of structural MRI, which depicts the trigeminal nerve and surrounding cisternal anatomy, and time-of-flight MRA, which highlights vascular structures. Although MRI-MRA fusion is clinically attractive for visualizing neurovascular compression, this task is poorly captured by conventional whole-brain registration evaluation because the clinically relevant target is a small trigeminal ROI, vessel annotations are partial and clinically focused, local TOF-MRA contrast is variable, and field-of-view mismatch can limit deformable alignment. We formulate TN MRI-MRA fusion as an ROI-centered neurovascular registration-evaluation problem and construct a benchmark from 149 patients with clinician-annotated bilateral trigeminal ROIs. Six representative registration pipelines were evaluated using local image-based metrics, segmentation-derived vessel-localization metrics, prediction-volume analysis, and contrast- and FOV-stratified comparisons. Conventional evaluation summaries were often misleading: local image similarity, vessel-background separability, and downstream vessel localization did not co-rank methods; one-sided vessel distances were strongly affected by predicted vessel extent under partial annotations; and local MRA contrast determined when vessel-separability metrics were informative. Deformable refinement provided only a small, FOV-dependent benefit over affine alignment, while reader review showed that locally favorable vessel distances could coexist with globally implausible registrations. These findings indicate that TN MRI-MRA registration should be evaluated as a local, vessel-aware, contrast-sensitive, and FOV-aware visualization task rather than as generic multimodal brain registration. Our code is publicly available at https://github.com/jhuldr/TN-Reg-Benchmark.
Related papers
- How Good are Foundation Models in Longitudinal MRI Disease Progression Reasoning? [49.14050864978079]
We introduce the Time-Aware Multi-View MRI Benchmark, an evaluation framework unifying multi-view anatomical input, temporal reasoning, and structured localization guidance.<n>The benchmark comprises 3,920 expert-verified question-answer pairs derived from 890 patients across over 3,200 longitudinal MRI timepoints.
arXiv Detail & Related papers (2026-08-13T14:35:20Z) - Rendering Novel Views of MRI Using 3D Gaussian Splatting [54.6286495315908]
We adapt 3D Gaussian Splatting to form a reconstruction starting from sparse anisotropic MRIs, and imaging planes aligned with the anatomy relevant for clinical evaluation are then sampled and rendered.<n>The novel view plane is optimal for diagnostic radiological grading of the target anatomy, whereas the original MRI is not.
arXiv Detail & Related papers (2026-06-24T18:00:03Z) - Mamba-driven MRI-to-CT Synthesis for MRI-only Radiotherapy Planning [4.3531418255555545]
Mamba is a state-space model for cross-modality translation.<n>We adapt both the U-Mamba and the SegMamba architecture, originally proposed for segmentation, to perform cross-modality image generation.<n>Our 3D Mamba architecture effectively captures complex features and long-range volumetric dependencies, thus allowing accurate CT synthesis.
arXiv Detail & Related papers (2026-03-24T14:56:39Z) - Stroke Locus Net: Occluded Vessel Localization from MRI Modalities [4.014411945095764]
Stroke Locus Net is an end-to-end deep learning pipeline for detection, segmentation, and occluded vessel localization using only MRI scans.<n>Our implementation demonstrates promising results in localizing occluded vessels on stroke-affected T1 MRI scans, with potential for faster and more informed stroke diagnosis.
arXiv Detail & Related papers (2025-10-11T10:30:17Z) - A 3D Cross-modal Keypoint Descriptor for MR-US Matching and Registration [0.053801353100098995]
Intraoperative registration of real-time ultrasound to preoperative Magnetic Resonance Imaging (MRI) remains an unsolved problem.<n>We propose a novel 3D cross-modal keypoint descriptor for MRI-iUS matching and registration.<n>Our approach employs a patient-specific matching-by-synthesis approach, generating synthetic iUS volumes from preoperative MRI.
arXiv Detail & Related papers (2025-07-24T16:19:08Z) - RSF-Conv: Rotation-and-Scale Equivariant Fourier Parameterized Convolution for Retinal Vessel Segmentation [58.618797429661754]
We propose a rotation-and-scale equivariant Fourier parameterized convolution (RSF-Conv) specifically for retinal vessel segmentation.
As a general module, RSF-Conv can be integrated into existing networks in a plug-and-play manner.
To demonstrate the effectiveness of RSF-Conv, we also apply RSF-Conv+U-Net and RSF-Conv+Iter-Net to retinal artery/vein classification.
arXiv Detail & Related papers (2023-09-27T13:14:57Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z) - Localizing the Recurrent Laryngeal Nerve via Ultrasound with a Bayesian
Shape Framework [65.19784967388934]
Tumor infiltration of the recurrent laryngeal nerve (RLN) is a contraindication for robotic thyroidectomy and can be difficult to detect via standard laryngoscopy.
We propose a knowledge-driven framework for RLN localization, mimicking the standard approach surgeons take to identify the RLN according to its surrounding organs.
Experimental results indicate that the proposed method achieves superior hit rates and substantially smaller distance errors compared with state-of-the-art methods.
arXiv Detail & Related papers (2022-06-30T13:04:42Z) - A Long Short-term Memory Based Recurrent Neural Network for
Interventional MRI Reconstruction [50.1787181309337]
We propose a convolutional long short-term memory (Conv-LSTM) based recurrent neural network (RNN), or ConvLR, to reconstruct interventional images with golden-angle radial sampling.
The proposed algorithm has the potential to achieve real-time i-MRI for DBS and can be used for general purpose MR-guided intervention.
arXiv Detail & Related papers (2022-03-28T14:03:45Z) - The Brain Tumor Sequence Registration (BraTS-Reg) Challenge: Establishing Correspondence Between Pre-Operative and Follow-up MRI Scans of Diffuse Glioma Patients [31.567542945171834]
We describe the Brain Tumor Sequence Registration (BraTS-Reg) challenge.
BraTS-Reg is the first public benchmark environment for deformable registration algorithms.
The aim of BraTS-Reg is to continue to serve as an active resource for research.
arXiv Detail & Related papers (2021-12-13T19:25:16Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.