Power Dependent Resonant Frequency of a Microwave Cavity due to Magnetic
Levitation
- URL: http://arxiv.org/abs/2211.06815v1
- Date: Sun, 13 Nov 2022 04:42:37 GMT
- Title: Power Dependent Resonant Frequency of a Microwave Cavity due to Magnetic
Levitation
- Authors: N. K. Raut, J. Miller, H. Hart, R. Chiao, and J. E. Sharping
- Abstract summary: We report measurements of the change in resonance frequency of the microwave cavity with the Meissner-levitated permanent magnet.
The change in resonate frequency is likely due to the interaction of the magnet with the radio-frequency field inside the microwave cavity.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Levitation of a magnet by superconductor has been an active area of research
to explore the quantum mechanical phenomenon. One of the techniques used is to
measure the levitation of a magnet placed inside the superconducting microwave
cavity. The levitation height can be probed by measuring the change in
microwave frequency. Here, we report measurements of the change in resonance
frequency of the microwave cavity with the Meissner-levitated permanent magnet.
The change in resonant frequency and quality factor was measured as a function
of input power and temperature. The change in resonate frequency is likely due
to the interaction of the magnet with the radio-frequency field inside the
microwave cavity.
Related papers
- Observation and control of hybrid spin-wave-Meissner-current transport
modes [0.0]
Superconductors are materials with zero electrical resistivity and the ability to expel magnetic fields known as the Meissner effect.
We use superconducting diamagnetism to shape the magnetic environment governing the transport of spin waves in a thin-film magnet.
Our results demonstrate the versatility of superconductor-manipulated spin-wave transport and have potential applications in spin-wave gratings, filters, crystals and cavities.
arXiv Detail & Related papers (2023-07-14T19:05:51Z) - Imaging magnetism evolution of magnetite to megabar pressure range with
quantum sensors in diamond anvil cell [57.91882523720623]
We develop an in-situ magnetic detection technique at megabar pressures with high sensitivity and sub-microscale spatial resolution.
We observe the macroscopic magnetic transition of Fe3O4 in the megabar pressure range from strong ferromagnetism (alpha-Fe3O4) to weak ferromagnetism (beta-Fe3O4) and finally to non-magnetism (gamma-Fe3O4)
The presented method can potentially investigate the spin-orbital coupling and magnetism-superconductivity competition in magnetic systems.
arXiv Detail & Related papers (2023-06-13T15:19:22Z) - Measuring the magnon-photon coupling in shaped ferromagnets: tuning of
the resonance frequency [50.591267188664666]
cavity photons and ferromagnetic spins excitations can exchange information coherently in hybrid architectures.
Speed enhancement is usually achieved by optimizing the geometry of the electromagnetic cavity.
We show that the geometry of the ferromagnet plays also an important role, by setting the fundamental frequency of the magnonic resonator.
arXiv Detail & Related papers (2022-07-08T11:28:31Z) - Magnetic levitation within a microwave cavity: characterization,
challenges, and possibilities [0.0]
Low energy losses in superconducting magnetic levitation make it attractive for exciting applications in physics.
Meissner levitation within the microwave cavity could open avenues for the novel cavity optomechanical system.
arXiv Detail & Related papers (2022-07-04T20:13:54Z) - Nanoscale magnetism probed in a matter-wave interferometer [0.0]
We study alkali atoms, organic radicals and fullerenes in the same device, with magnetic moments ranging from a Bohr magneton to less than a nuclear magneton.
We find evidence for magnetization of a supersonic beam of organic radicals and, most notably, observe a strong magnetic response of a thermal C$_60$ beam consistent with high-temperature atom-like deflection of rotational magnetic moments.
arXiv Detail & Related papers (2022-03-22T16:42:48Z) - Surpassing the Energy Resolution Limit with ferromagnetic torque sensors [55.41644538483948]
We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit.
We find that the Energy Resolution Limit (ERL), pointed out in recent literature, can be surpassed by many orders of magnitude.
arXiv Detail & Related papers (2021-04-29T15:44:12Z) - Detecting spins with a microwave photon counter [0.0]
We demonstrate the detection of a small ensemble of donor spins in silicon by their fluorescence at microwave frequency and millikelvin temperatures.
We discuss the potential of fluorescence detection as a novel method for magnetic resonance spectroscopy of small numbers of spins.
arXiv Detail & Related papers (2021-02-02T10:12:48Z) - Demonstrating levitation within a microwave cavity [0.0]
We report the first successful experiments with a levitated millimeter-scale neodymium magnet within a centimeter-scale superconducting aluminum coaxial quarter-wave stub cavity.
Resonance spectra are collected via a vector network analyzer (VNA) between temperatures of 5 K and 50 mK revealing movement of the magnet inside of the cavity.
arXiv Detail & Related papers (2021-01-05T01:42:09Z) - Photon Condensation and Enhanced Magnetism in Cavity QED [68.8204255655161]
A system of magnetic molecules coupled to microwave cavities undergoes the equilibrium superradiant phase transition.
The effect of the coupling is first illustrated by the vacuum-induced ferromagnetic order in a quantum Ising model.
A transmission experiment is shown to resolve the transition, measuring the quantum electrodynamical control of magnetism.
arXiv Detail & Related papers (2020-11-07T11:18:24Z) - Gravity Probe Spin: Prospects for measuring general-relativistic
precession of intrinsic spin using a ferromagnetic gyroscope [51.51258642763384]
An experimental test at the intersection of quantum physics and general relativity is proposed.
The behavior of intrinsic spin in spacetime is an experimentally open question.
A measurement is possible by using mm-scale ferromagnetic gyroscopes in orbit around the Earth.
arXiv Detail & Related papers (2020-06-16T17:18:44Z) - Optical Magnetometer: Quantum Resonances at pumping repetition rate of
1/n of the Larmor frequency [58.720142291102135]
Quantum sub-resonances at a repetition rate of $1/n$ of the Larmor frequency of the magnetic field inside the shield are experimentally observed and theoretically explained.
Investigations in single alkali atoms cells as well as mixed alkali atoms of K and Rb are presented.
arXiv Detail & Related papers (2020-02-20T09:14:56Z)
This list is automatically generated from the titles and abstracts of the papers in this site.