All-Optical Nonzero-Field Vector Magnetic Sensor For
Magnetoencephalography
- URL: http://arxiv.org/abs/2303.15974v1
- Date: Tue, 28 Mar 2023 13:46:17 GMT
- Title: All-Optical Nonzero-Field Vector Magnetic Sensor For
Magnetoencephalography
- Authors: Mikhail V. Petrenko, Anatoly S. Pazgalev, and Anton K. Vershovskii
- Abstract summary: The scheme differs from the classical two-beam Bell-Bloom scheme in that the detecting laser beam is split into two beams.
The proposed sensor is compact, resistant to variations of parameters of laser radiation and highly sensitive to the angle of deflection of the magnetic field vector.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: We present the concept and the results of an investigation of an all-optical
vector magnetic field sensor scheme developed for biological applications such
as non-zero field magnetoencephalography and magnetocardiography. The scheme
differs from the classical two-beam Bell-Bloom scheme in that the detecting
laser beam is split into two beams, which are introduced into the cell in
orthogonal directions, and the ratio of the amplitudes of the magnetic
resonance signals in these beams and their phase difference are measured;
strong optical pumping from the lower hyperfine level of the ground state
ensures the resonance line narrowing, and detection in two beams is carried out
in a balanced schemes by measuring the beam polarization rotation. The proposed
sensor is compact, resistant to variations of parameters of laser radiation and
highly sensitive to the angle of deflection of the magnetic field vector - with
an estimated scalar sensitivity of the order of 16 fT/Hz1/2 in 8x8x8 mm3 cell,
an angular sensitivity of 4x10-7 rad, or 0.08'', was demonstrated.
Related papers
- Vector Magnetometry Using Shallow Implanted NV Centers in Diamond with Waveguide-Assisted Dipole Excitation and Readout [34.114534806002595]
Nitrogen-Vacancy (NV) centers in diamond require scalable integration of 3D waveguides into diamond substrates.
We develop a sensing array device with an ensemble of shallow implanted NV centers integrated with arrays of laser-written waveguides for excitation and readout of NV signals.
arXiv Detail & Related papers (2024-07-26T12:55:25Z) - In-situ-tunable spin-spin interactions in a Penning trap with in-bore
optomechanics [41.94295877935867]
We present an optomechanical system for in-situ tuning of the coherent spin-motion and spin-spin interaction strength.
We characterize the system using measurements of the induced mean-field spin precession.
These experiments show approximately a $times2$ variation in the ratio of the coherent to incoherent interaction strength.
arXiv Detail & Related papers (2024-01-31T11:00:39Z) - Zero-field optical magnetometer based on spin-alignment [0.2407976495888858]
This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero-field.
The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal.
Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
arXiv Detail & Related papers (2023-08-23T16:15:10Z) - High Dynamic Range Vector Atomic Magnetometer with 1 part-per-billion Resolution in Earth Field Range [3.3973386812990904]
We present a high-dynamic-range vector atomic magnetometer based on applying a fast-rotating magnetic field to a pulsed $87$Rb scalar atomic magnetometer.
This method enables simultaneous measurements of the total magnetic field and two polar angles relative to the plane of magnetic field rotation.
arXiv Detail & Related papers (2023-04-01T03:25:22Z) - Sensitivity Comparison of Two-photon vs Three-photon Rydberg
Electrometry [45.82374977939355]
We model the 4-level and 5-level atomic system and compare how the transmission of the probe changes with different powers of the lasers used and strengths of the RF field.
We find that the three-photon system boasts much narrower line widths compared to the conventional two-photon EIT.
In addition to this, we calculate the expected sensitivity for the two-photon Rydberg sensor and find that the best achievable sensitivity is over an order of magnitude better than the current measured values of 5 uV/m/Hz.
arXiv Detail & Related papers (2022-11-21T20:46:24Z) - Fiber-coupled Diamond Magnetometry with an Unshielded 30
pT/$\sqrt{\textrm{Hz}}$ Sensitivity [0.0]
We present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $pm$ 10) pT/$sqrttextrmHz$ in a (10 - 500)-Hz frequency range.
This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias field alignment, microwave and lock-in amplifier (LIA) parameter optimisation, as well as a balanced hyperfine excitation scheme.
The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with
arXiv Detail & Related papers (2022-11-16T19:35:51Z) - Investigation and comparison of measurement schemes in the low frequency
biosensing regime using solid-state defect centers [58.720142291102135]
Solid state defects in diamond make promising quantum sensors with high sensitivity andtemporal resolution.
Inhomogeneous broadening and drive amplitude variations have differing impacts on the sensitivity depending on the sensing scheme used.
We numerically investigate and compare the predicted sensitivity of schemes based on continuous-wave (CW) optically detected magnetic resonance (ODMR) spectroscopy, pi-pulse ODMR and Ramsey interferometry.
arXiv Detail & Related papers (2021-09-27T13:05:23Z) - Diamond magnetometry and gradiometry towards subpicotesla DC field
measurement [2.405499311102098]
Nitrogen vacancy (NV) centers in diamond have developed into a powerful solid-state platform for compact quantum sensors.
We demonstrate high sensitivity NV ensemble based magnetic field measurements with low-intensity optical excitation.
arXiv Detail & Related papers (2020-12-31T16:46:39Z) - An integrated magnetometry platform with stackable waveguide-assisted
detection channels for sensing arrays [45.82374977939355]
We present a novel architecture which allows us to create NV$-$-centers a few nanometers below the diamond surface.
We experimentally verify the coupling efficiency, showcase the detection of magnetic resonance signals through the waveguides and perform first proof-of-principle experiments in magnetic field and temperature sensing.
In the future, our approach will enable the development of two-dimensional sensing arrays facilitating spatially and temporally correlated magnetometry.
arXiv Detail & Related papers (2020-12-04T12:59:29Z) - High-Frequency Gravitational-Wave Detection Using a Chiral Resonant
Mechanical Element and a Short Unstable Optical Cavity [59.66860395002946]
We suggest the measurement of the twist of a chiral mechanical element induced by a gravitational wave.
The induced twist rotates a flat optical mirror on top of this chiral element, leading to the deflection of an incident laser beam.
We estimate a gravitational wave strain sensitivity between 10-21/sqrtHz and 10-23/sqrtHz at around 10 kHz frequency.
arXiv Detail & Related papers (2020-07-15T20:09:43Z) - Simultaneous Wide-field Imaging of Phase and Magnitude of AC Magnetic
Signal Using Diamond Quantum Magnetometry [0.0]
A simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated.
Our method enables potential applications including inductive inspection and impedance imaging.
arXiv Detail & Related papers (2020-01-08T04:56:11Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.