Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT/rHz
- URL: http://arxiv.org/abs/2309.11825v2
- Date: Thu, 20 Jun 2024 01:42:27 GMT
- Title: Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT/rHz
- Authors: Hamish A. M. Taylor, Christopher C. Bounds, Alex Tritt, L. D. Turner,
- Abstract summary: We describe how Hilbert-demodulated optical magnetometry can be realised on cold atom sensors.
We measure a test field to be $ 86.0121261(4) ; mathrmmu T$ in a single shot, achieving dc sensitivity of 380 fT in a duration of 1000 ms.
- Score: 0.0
- License: http://creativecommons.org/licenses/by-nc-sa/4.0/
- Abstract: Cold atom magnetometers exploit a dense ensemble of quanta with long coherence times to realise leading sensitivity on the micrometer scale. Configured as a Ramsey interferometer, a cold atom sensor can approach atom shot-noise limited precision but suffers from fringe ambiguity, producing gross errors when the field falls outside a narrow predefined range. We describe how Hilbert-demodulated optical magnetometry can be realised on cold atom sensors to provide field measurements both precise and unambiguous. Continuous reconstruction of the Larmor phase allows us to determine the dc magnetic field unambiguously in an unshielded environment, as well as measure ac variation of the field, in a single shot. The ac measurement allows us to characterize, and then neutralise, line-synchronous magnetic interference, extending reconstruction times. Using $1.6 \times 10^6$ $^{87}$Rb atoms in a volume of $(68 \,\mathrm{\mu m})^3$, we measure a test field to be $ 86.0121261(4) \; \mathrm{\mu T}$ in a single shot, achieving dc sensitivity of 380 fT in a duration of 1000 ms. Our results demonstrate that Hilbert-demodulated optical readout yields metrologically-significant sensitivity without the fringe ambiguity inherent to Ramsey interferometry.
Related papers
- Metrology of microwave fields based on trap-loss spectroscopy with cold Rydberg atoms [32.73124984242397]
We demonstrate a new approach for the metrology of microwave fields based on the trap-loss-spectroscopy of cold Rydberg atoms in a magneto-optical trap.
Compared to state-of-the-art sensors using room-temperature vapors, cold atoms allow longer interaction times, better isolation from the environment and a reduced Doppler effect.
arXiv Detail & Related papers (2024-04-26T14:30:18Z) - Optically-biased Rydberg microwave receiver enabled by hybrid nonlinear
interferometry [0.0]
coupling of Rydberg vapors medium both to microwave and optical fields allows harnessing the merits of all-optical detection.
We propose optical-bias detection, that allows truly all-optical operation, while retaining most of the sensitivity.
We report the sensitivity of $176 mathrmnV/cm/sqrtHz$ and reliable operation up to $3.5 mathrmmV/cm$ of $13.9 mathrmGHz$ electric field.
arXiv Detail & Related papers (2024-03-08T13:39:45Z) - Quantum enhanced sensing by echoing spin-nematic squeezing in atomic
Bose-Einstein condensate [20.71025384963426]
We present protocols based on echoing spin-nematic squeezing to achieve record high enhancement factors in atomic Bose-Einstein condensate.
Our work highlights the excellent many-body coherence of spin-nematic squeezing and suggests its possible quantum metrological applications in atomic magnetometer, atomic optical clock, and fundamental testing of Lorentz symmetry violation, etc.
arXiv Detail & Related papers (2022-12-18T16:40:28Z) - Improving Sensitivity of an Amplitude-Modulated Magneto-Optical Atomic
Magnetometer using Squeezed Light [10.396267889929488]
A squeezed probe optical field can improve the sensitivity of the magnetic field measurements based on nonlinear magneto-optical rotation.
An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields.
arXiv Detail & Related papers (2022-07-26T15:15:44Z) - Development of a compact high-resolution absolute gravity gradiometer
based on atom interferometers [29.588678452286015]
We present a compact high-resolution gravity gradiometer based on dual Rb-85 atom interferometers.
A phase resolution of 104 murad is achieved, which corresponds to a gravity gradient resolution of 0.86 E.
arXiv Detail & Related papers (2022-02-24T11:05:49Z) - High-resolution 'magic'-field spectroscopy on trapped polyatomic
molecules [62.997667081978825]
Rapid progress in cooling and trapping of molecules has enabled first experiments on high resolution spectroscopy of trapped diatomic molecules.
Extending this work to polyatomic molecules provides unique opportunities due to more complex geometries and additional internal degrees of freedom.
arXiv Detail & Related papers (2021-10-21T15:46:17Z) - Cavity-enhanced magnetometer with a spinor Bose-Einstein condensate [0.0]
The sensitivity of the proposed magnetometer exhibits Heisenberg-like scaling with respect to the atom number.
We calculate the lower bound on the sensitivity of such a magnetometer to be of the order of fT/$sqrtmathrmHz$--pT/$sqrtmathrmHz$ for a condensate of $104$ atoms with coherence times of the order of several ms.
arXiv Detail & Related papers (2020-08-17T12:20:05Z) - High-Frequency Gravitational-Wave Detection Using a Chiral Resonant
Mechanical Element and a Short Unstable Optical Cavity [59.66860395002946]
We suggest the measurement of the twist of a chiral mechanical element induced by a gravitational wave.
The induced twist rotates a flat optical mirror on top of this chiral element, leading to the deflection of an incident laser beam.
We estimate a gravitational wave strain sensitivity between 10-21/sqrtHz and 10-23/sqrtHz at around 10 kHz frequency.
arXiv Detail & Related papers (2020-07-15T20:09:43Z) - A robust fiber-based quantum thermometer coupled with nitrogen-vacancy
centers [29.359306535600815]
We present a robust fiber-based quantum thermometer which can significantly isolate the magnetic field noise and microwave power shift.
With a frequency modulation scheme, we realize the temperature measurement by detecting the variation of the sharp-dip in the zero-field optically detected magnetic resonance spectrum.
arXiv Detail & Related papers (2020-04-09T03:24:52Z) - Limitations for field-enhanced atom interferometry [0.0]
We discuss the possibility to enhance the sensitivity of optical interferometric devices by increasing its open area.
The use of combined electric and magnetic field cancel non linear terms that dephases the interferometer.
This is possible using well defined states, a magnetic field of few Tesla and an electric field gradient of $sim$ 10V/cm 2.
arXiv Detail & Related papers (2020-02-25T10:46:01Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.