Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
- URL: http://arxiv.org/abs/2401.04560v3
- Date: Mon, 26 Aug 2024 02:11:58 GMT
- Title: Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
- Authors: Gyutae Hwang, Sang Jun Lee,
- Abstract summary: Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system.
In this thesis, we propose a vision-based method for estimating the heart rate and blood pressure.
This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (BP-Net) and bounded blood pressure network (BBP-Net)
- Score: 4.392877207448768
- License: http://creativecommons.org/licenses/by-nc-nd/4.0/
- Abstract: Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.
Related papers
- Adversarial Contrastive Learning Based Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation [37.94387581519217]
We introduce a novel physics-informed temporal network(PITN) with adversarial contrastive learning to enable precise BP estimation with very limited data.
We then employ adversarial training to generate extra physiological time series data, improving PITN's robustness in the face of sparse subject-specific data.
arXiv Detail & Related papers (2024-08-16T02:17:21Z) - A Finger on the Pulse of Cardiovascular Health: Estimating Blood Pressure with Smartphone Photoplethysmography-Based Pulse Waveform Analysis [2.4347312660509672]
This study introduces four innovative strategies to enhance smartphone-based photoplethysmography for blood pressure estimation (SPW-BP)
We employ often-neglected data-quality improvement techniques, such as height normalization, corrupt data removal, and boundary signal reconstruction.
Correlation and SHAP analysis identified key features for improving BP estimation.
However, Bland-Altman analysis revealed systematic biases, and MAE analysis showed that the results did not meet AAMI and BHS accuracy standards.
arXiv Detail & Related papers (2024-01-20T05:05:17Z) - BrainZ-BP: A Non-invasive Cuff-less Blood Pressure Estimation Approach
Leveraging Brain Bio-impedance and Electrocardiogram [2.295711231919421]
Brain bio-impedance (BIOZ) is a promising technique for non-invasive intracranial pressure (ICP) monitoring.
Two electrodes are placed on the forehead and occipital bone of the head in the anterior-posterior direction for brain BIOZ measurement.
Various features including pulse transit time and morphological features of brain BIOZ are extracted and fed into four regression models for BP estimation.
Results show that the mean absolute error, root mean square error, and correlation coefficient of random forest regression model are 2.17 mmHg, 3.91 mmHg, and 0.90 for systolic pressure
arXiv Detail & Related papers (2023-11-18T07:10:32Z) - Video-based sympathetic arousal assessment via peripheral blood flow
estimation [46.695433930419945]
We present a novel approach to infer sympathetic arousal by measuring the peripheral blood flow on the face or hand optically.
We show that sympathetic arousal is best inferred from the forehead, finger, or palm.
arXiv Detail & Related papers (2023-11-12T19:06:33Z) - Improving Diffusion Models for ECG Imputation with an Augmented Template
Prior [43.6099225257178]
noisy and poor-quality recordings are a major issue for signals collected using mobile health systems.
Recent studies have explored the imputation of missing values in ECG with probabilistic time-series models.
We present a template-guided denoising diffusion probabilistic model (DDPM), PulseDiff, which is conditioned on an informative prior for a range of health conditions.
arXiv Detail & Related papers (2023-10-24T11:34:15Z) - Quality Assessment of Photoplethysmography Signals For Cardiovascular
Biomarkers Monitoring Using Wearable Devices [0.0]
Photoplethysmography is a non-invasive technology that measures changes in blood volume in the microvascular bed of tissue.
Photoplethysmography allows for the assessment of parameters that can indicate conditions such as vasoconstriction or vasodilation.
arXiv Detail & Related papers (2023-07-17T18:26:57Z) - Body Fat Estimation from Surface Meshes using Graph Neural Networks [48.85291874087541]
We show that triangulated body surface meshes can be used to accurately predict VAT and ASAT volumes using graph neural networks.
Our methods achieve high performance while reducing training time and required resources compared to state-of-the-art convolutional neural networks in this area.
arXiv Detail & Related papers (2023-07-13T10:21:34Z) - ReViSe: Remote Vital Signs Measurement Using Smartphone Camera [0.0]
Remote Photoplethysmography (rVi) is a fast, effective, inexpensive and convenient method for collecting biometric data.
We propose an end-to-end framework to measure people's vital signs based on the ruration of a user's face captured with a smartphone camera.
We extract face landmarks with a deep learning-based neural network model in real-time.
arXiv Detail & Related papers (2022-06-13T19:20:11Z) - A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP)
from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signals [1.1695966610359496]
Most existing methods used in the hospitals for continuous monitoring of Blood Pressure (BP) are invasive.
In this study, we explored the applicability of autoencoders in predicting BP from non-invasively collectible signals such as Photoplethysmogram ( PPG) and ECG signals.
It was found that a very shallow, one-dimensional autoencoder can extract the relevant features to predict the SBP and DBP with the state-of-the-art performance on a very large dataset.
arXiv Detail & Related papers (2021-11-12T19:34:20Z) - Ambulatory blood pressure monitoring versus office blood pressure
measurement: Are there sex differences? [55.41644538483948]
Office Blood Pressure Measurement (OBP) is a technique performed in-office with the sphygmomanometer, while Ambulatory Blood Pressure Monitoring (ABPM) is a technique that measures blood pressure during 24h.
The aim of this study is to examine the possible influence of sex on the discrepancies between OBP and ABPM in 872 subjects with known or suspected hypertension.
arXiv Detail & Related papers (2021-06-04T10:09:44Z) - Segmentation of the Myocardium on Late-Gadolinium Enhanced MRI based on
2.5 D Residual Squeeze and Excitation Deep Learning Model [55.09533240649176]
The aim of this work is to develop an accurate automatic segmentation method based on deep learning models for the myocardial borders on LGE-MRI.
A total number of 320 exams (with a mean number of 6 slices per exam) were used for training and 28 exams used for testing.
The performance analysis of the proposed ensemble model in the basal and middle slices was similar as compared to intra-observer study and slightly lower at apical slices.
arXiv Detail & Related papers (2020-05-27T20:44:38Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.